Siemens 6SE7090-0XX84-0FJ0 SIMOVERT MASTERDRIVES SLB SIMOLINK Board
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Conectere ambo portus opticos in directione transmissionis recta.
- Tenere omnem nodum anelli potentiatum durante communicatione.
- Utere externum 24 V DC ubi continuitas anelli post extinctionem hostis requiritur.
- Reservare fessuram C pro tabula sensoria si praesens est et uti aliam fessuram idoneam pro SLB.
6SE7090-0XX84-0FJ0 SIMOVERT MASTERDRIVES SLB SIMOLINK Board
The SLB board links MASTERDRIVES units into a fiber-optic SIMOLINK ring for data exchange and synchronization, with external 24 V DC supply support.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SE7090-0XX84-0FJ0 |
| Typus Producti | Drive communication option board |
| Functio principalis | SIMOLINK drive data exchange |
| Applicatio | Compatible MASTERDRIVES converters and inverters |
Opticum anellum ligaturam
SIMOLINK utitlizat conexiones opticas specializatas pro input e output.
Dispatcher o transceptor
Le parameterisation seligit le rolo del scheda in le anello.
Input de alimentation externe
Un alimentation de 24 V DC pote mantener le nodo del anello active dumque le convertitor es disactivate.
Product Overview
6SE7090-0XX84-0FJ0 es le scheda optionale SLB SIMOLINK pro unitates compatibile de SIMOVERT MASTERDRIVES. Illo intercambia datos de motores e synchronisa le motores participante a un orologio systematico commun per un anello optic de fibre.
Le scheda pote operar como dispatcher o transceptor, lege le telegrammas del anello e immagazina datos selecte, dumque su connexion de alimentation externe supporta le continuitate del anello quando le convertitor hospite es disactivate.
Key Functions
Communication synchronisate de motores
Le anello SIMOLINK transferi datos inter le motores participante e provide un orologio systematico commun pro synchronisation.
Rolus nodi seligibilis
Parameterizatio operationem distributoris vel transceptoris seligit, cum usque ad 201 nodos in anulo permitti possint.
Continuitas potestatis et diagnostica
Externa alimentatio 24 V DC operationem independentem a potentia converteris hospitis sustinet, et tres LED statum operationis tabulae indicant.
Official Specifications
| Celeritas Transferendi Datorum | 11 MBaud |
|---|---|
| Magnitudo maxima anuli | 201 nodi |
| Requisitum internae supplicationis | 5 V DC, maximum 600 mA |
| Requisitum alimentationis externae | 24 V DC, maximum 200 mA |
| Maxima distantia inter nodos ex fibra plastica | 40 m |
| Maxima distantia inter nodos ex fibra vitrea | 300 m |
| Maxima mora propagationis | tres tempora horologii |
| Magnitudo tabulae (longitudo × latitudo) | 90 × 83 mm |
| Refrigerans | Refrigeratio aere naturali |
| Temperatura operativa | 0 ad 70 °C |
| Temperatura servandi et transportandi | −25 ad +70 °C |
| Humiditas relativa | Maxime 85% in operatione; 95% in conservatione et transportu; nulla condensatio |
| Gradus Contaminations | 2 |
| Classis climatica operationis | 3K3 secundum DIN IEC 721-3-3 |
Quaestiones Frequenter Rogatae
Necne utrumque portum opticum coniungere oportet in 6SE7090-0XX84-0FJ0?
Utrumque opticum introitum et opticum exitum coniungi oportet, ut anulus SIMOLINK clausus perficiatur.
Quis connector opticus est introitus in 6SE7090-0XX84-0FJ0?
Inferior connexio subnigra est introitus, superior connexio subalba est exitus.
Num 6SE7090-0XX84-0FJ0 anulum in cursu retinere potest, dum converter hostis exstinctus est?
Externa supplitio 24 V DC tabulam in operatione tenet, ut translatio datorum per anulum continuari possit, etiam cum converter exstinctus est.
Num supplitio externa a 6SE7090-0XX84-0FJ0 removeri potest dum anulus normaliter operatur?
Removere supplitium externum dum bus operatur non permittitur, quia commutatio supplitii tabulam reinitiat et telegrammata amittit.
Quomodo operationem dispatcher vel transceiver in 6SE7090-0XX84-0FJ0 seligo?
Officium operativum per parametrizationem seligitur.
Num inter 6SE7090-0XX84-0FJ0 et nodum proximum spatium fibrae plasticae 100 m uti possum?
Fibra plastic est limitata a 40 m inter nodos, dum fibra de vitre permitte usque ad 300 m.
Possumne installare 6SE7090-0XX84-0FJ0 in fessura C quando un tabula sensoria iam requirit illam fessuram?
Tabula sensoria requirit fessuram C, ergo tabula SIMOLINK debet uti alia fessura idonea.