Siemens · SIMATIC NET CP 343-2

6GK7343-2AH00-0XA0 AS-Interface Master Communications Processor

Siemens 6GK7343-2AH00-0XA0 is a single-width CP 343-2 communications processor that connects an S7-300 or ET 200M station to one AS-Interface branch as an AS-i V2.1 master.

At a Glance

Brand Siemens
Model 6GK7343-2AH00-0XA0
Product Type CP 343-2 AS-Interface Master
Core Function Controls an AS-i sensor and actuator network from the PLC rack
Application or Compatible Series SIMATIC S7-300 and ET 200M stations

Slave Profile Audit

Check every installed slave profile against an AS-i V2.1 master before migrating an existing branch.

Addressing Mode

Use standard addressing for up to 31 slaves or extended A/B addressing for up to 62 compatible slaves.

Power and Connector Check

Verify the 20-pole screw-contact front connector, AS-i cable voltage and branch current before startup.

Product Overview

Siemens 6GK7343-2AH00-0XA0 is a single-width CP 343-2 communications processor that connects an S7-300 or ET 200M station to one AS-Interface branch as an AS-i V2.1 master.

The processor exchanges cyclic data with addressed sensors and actuators on one AS-i branch. Commissioning is possible from the module controls or through STEP 7 with the ASI_3422 function. The branch can operate up to 62 compatible A/B slaves with a 10 ms bus cycle.

Ordering focus: confirm the exact CP 343-2 article number, S7-300 or ET 200M slot, AS-i V2.1 slave profiles, addressing mode, 20-pole screw connector, address allocation and AS-i supply.

Key Functions

Central AS-i Master Control

The processor exchanges cyclic data with addressed sensors and actuators on one AS-i branch.

Local or STEP 7 Configuration

Commissioning is possible from the module controls or through STEP 7 with the ASI_3422 function.

Extended Slave Addressing

The branch can operate up to 62 compatible A/B slaves with a 10 ms bus cycle.

Official Specifications

AS-i Master Profile M4
AS-Interface Specification V2.1
Standard Slave Capacity Up to 31 slaves
Extended Addressing Capacity Up to 62 compatible A/B slaves
Bus Cycle with 31 Slaves 5 ms
Bus Cycle with 62 Slaves 10 ms
Configuration Methods Front-panel buttons or STEP 7 using FC ASI_3422
AS-i Cable Connection 20-pole S7-300 front connector with screw contacts
Front-Connector Contact Current 4 A maximum between contacts 17 and 19 and between contacts 18 and 20
PLC Address Allocation 16 input bytes and 16 output bytes in the S7-300 analog address area
Backplane-Bus Current at 5 V DC 200 mA maximum
Current Drawn from AS-i Cable 100 mA maximum
AS-i Cable Supply Range 29.5 to 31.6 V DC
Horizontal Operating Temperature 0 to 60 °C
Vertical Operating Temperature 0 to 40 °C
Transport and Storage Temperature -40 to 70 °C
Maximum Relative Humidity 95% at 25 °C
Module Format S7-300 compact module, single width
Dimensions 40 × 125 × 115 mm
Approximate Weight 200 g

Frequently Asked Questions

How many standard AS-i slaves can 6GK7343-2AH00-0XA0 operate?

The master can operate up to 31 slaves with a 5 ms bus cycle.

Can 6GK7343-2AH00-0XA0 use A/B slave addressing?

Extended addressing allows up to 62 compatible A/B slaves with a 10 ms bus cycle.

How do I configure 6GK7343-2AH00-0XA0 during commissioning?

Configuration can be completed with the front-panel controls or downloaded from STEP 7 using the ASI_3422 function.

Which front connector is required for 6GK7343-2AH00-0XA0?

The AS-i cable connects through a 20-pole S7-300 front connector with screw contacts.

How much PLC address space does 6GK7343-2AH00-0XA0 reserve?

The module occupies 16 input bytes and 16 output bytes in the analog address area.

Can 6GK7343-2AH00-0XA0 operate AS-i 3.0 Combined Transaction Type slaves?

Combined Transaction Type 2 through 5 slaves are not compatible with this V2.1 master.

Why does mounting orientation matter for 6GK7343-2AH00-0XA0?

Horizontal installation permits operation up to 60 °C, while vertical installation is limited to 40 °C.

Compatibility & Ordering Notes

Before ordering 6GK7343-2AH00-0XA0: confirm the exact CP 343-2 article number, S7-300 or ET 200M slot, AS-i V2.1 slave profiles, addressing mode, 20-pole screw connector, address allocation and AS-i supply.

Compatibility Checklist

  • Confirm an S7-300 or ET 200M rack position for a single-width module.
  • Match the complete -2AH00-0XA0 order number rather than an AH01 or CP 343-2 P variant.
  • Inventory every slave profile and verify compatibility with AS-i V2.1.
  • Do not use AS-i 3.0 Combined Transaction Type 2 through 5 slaves on this master.
  • Reserve 16 input bytes and 16 output bytes in the analog address area.
  • Provide the correct 20-pole screw-contact front connector.
  • Verify that the AS-i supply remains between 29.5 and 31.6 V DC.
Hot Selling Models
KCD2-E2L
XVBC34CA
3RH2122-2BB40 3RT2916-1BB00
18141749
CA2KN22P7
428-433 MDR-20-24
IME12-08NPSZC0S
231932 0100N
ST2.5/1P 3040012
CA2KN31F7 042838
3RH1262-2AP00
CA2KN31M7 050030
SNC32
GV100 P15/150S
EL9011

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.