Siemens 6ES7422-1BH11-0AA0 SIMATIC S7-400 SM 422 Digital Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC S7-400 SM 422

6ES7422-1BH11-0AA0 SIMATIC S7-400 SM 422 Digital Output Module

SM 422 with sixteen 24 V DC / 2 A outputs, electronic short-circuit protection and potential separation in groups of eight.

At a Glance

Brand Siemens
Model 6ES7422-1BH11-0AA0
Product Type Digital output module
Core Function DC actuator signal switching
Application S7-400 rack-based control systems

Sixteen DC output channels

Rated two-ampere outputs switch compatible twenty-four-volt field loads.

Electronic load-fault protection

Clocked electronic short-circuit protection responds at the specified threshold range.

Grouped potential separation

Groups of eight outputs are isolated within the module arrangement and from the backplane bus.

Product Overview

6ES7422-1BH11-0AA0 provides sixteen DC load outputs for an S7-400 station.

The module combines two-ampere rated channels with defined load-switching limits, electronic fault-current protection and grouped potential separation from the backplane.

Ordering focus: Match the load voltage, actuator current, isolation groups and load-dependent switching rate.
Key Functions

Sixteen DC output channels

Rated two-ampere outputs switch compatible twenty-four-volt field loads.

Electronic load-fault protection

Clocked electronic short-circuit protection responds at the specified threshold range.

Grouped potential separation

Groups of eight outputs are isolated within the module arrangement and from the backplane bus.

Official Specifications
Load supply 24 V DC; permitted 20.4–28.8 V
Maximum no-load current 30 mA from L+; 160 mA from the 5 V backplane
Typical power loss 5 W
Output channels and rated current 16 outputs; 2 A per channel
Permitted on-state current 5 mA to 2.4 A
Maximum off-state residual current 0.5 mA
Minimum on-state voltage L+ minus 0.5 V
Clocked short-circuit response Electronic; typical threshold 2.8–6 A
Inductive turn-off voltage limit −30 V
Maximum lamp load 10 W per output
Load resistance range 24 Ω to 4 kΩ
Output delays Maximum 1 ms for both on and off transitions with resistive load
Resistive and lamp switching Maximum 100 Hz resistive; 10 Hz lamp load
DC13 inductive switching Maximum 0.2 Hz at 1 A; 0.1 Hz at 2 A
Maximum output cable 1000 m shielded or 600 m unshielded
Potential separation and test Groups of 8; isolated from the backplane; 500 V DC isolation test
Dimensions and approximate weight 25 × 290 × 210 mm (W × H × D); 600 g
Frequently Asked Questions

Should I treat every output on 6ES7422-1BH11-0AA0 as an individually isolated circuit?

Potential separation is provided in groups of eight and between the outputs and the backplane bus.

How frequently can 6ES7422-1BH11-0AA0 switch a two-ampere DC13 inductive load?

The maximum DC13 switching frequency at two amperes is one-tenth hertz.

Can I rely on 6ES7422-1BH11-0AA0 for a diagnostic function in the controller?

The module does not provide a diagnostics function.

Is a five-hundred-metre unshielded output cable within the limit for 6ES7422-1BH11-0AA0?

The stated maximum unshielded output-cable length is six hundred metres.

What unloaded current should I budget for 6ES7422-1BH11-0AA0 on the two supplies?

Allow up to thirty milliamperes from the load supply and one hundred sixty milliamperes from the five-volt backplane.

Can I connect a twenty-watt lamp directly to an output of 6ES7422-1BH11-0AA0?

The specified maximum lamp load is ten watts per output.

Can I parallel two outputs of 6ES7422-1BH11-0AA0 to increase the load-current rating?

Parallel switching for current uprating is not permitted.

Compatibility & Ordering Notes
Before ordering 6ES7422-1BH11-0AA0: Match the load voltage, actuator current, isolation groups and load-dependent switching rate.

Before installation

  • Use the matching S7-400 station and the specified twenty-four-volt DC load circuit.
  • Observe output grouping, current loading and the permitted load-specific switching frequency.
  • Do not parallel channels for current uprating; redundant control is limited to outputs in the same group.
  • Plan the field-cable length and controller fault handling without assuming a module diagnostics function.
Hot Selling Models
XB2 MD41
ADVUL-16-40-PA
289111-10
SC-E3/G SZ-Z36
0-901-34-448-6
6ES7370-0AA01-0AA0
ADVC-25-15-IPA
99.02.9.024.99
CPV10EPRU
Ni50U-QV40-AP6X2-H1141
AR20F02A
3RK1901-1GA00
VAA-4E4A-KE-ZEJQ/R-KRO
3TF40 22-4BB4
DIL2AM

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.