Siemens SIMATIC S7-400 6ES7407-0KA02-0AA0 PS 407 10 A Power Supply
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SIMATIC S7-400
6ES7407-0KA02-0AA0 PS 407 10 A Power Supply
Siemens 6ES7407-0KA02-0AA0 is a SIMATIC S7-400 PS 407 wide-range power-supply module that delivers the 5 V and 24 V DC backplane outputs required by the central rack.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7407-0KA02-0AA0 |
| Product Type | PLC rack power-supply module |
| Core Function | Converts wide-range AC or DC input into S7-400 backplane power |
| Application or Compatible Series | SIMATIC S7-400, S7-400H and S7-400F/FH systems |
Input Selection
Confirm the installed AC or DC supply and protective-conductor wiring.
Rack Capacity
Reserve two S7-400 rack slots and verify the connected backplane load.
Battery Provision
Match the optional backup-battery arrangement to the existing rack.
Product Overview
Siemens 6ES7407-0KA02-0AA0 is a SIMATIC S7-400 PS 407 wide-range power-supply module that delivers the 5 V and 24 V DC backplane outputs required by the central rack.
The module accepts the documented 120/230 V AC or DC nominal supply ranges. It provides 5.1 V DC and 24 V DC outputs for the S7-400 rack. The supply buffers brief input interruptions and supports optional lithium backup for retained data.
Key Functions
Wide-Range Supply Input
The module accepts the documented 120/230 V AC or DC nominal supply ranges.
Dual Backplane Outputs
It provides 5.1 V DC and 24 V DC outputs for the S7-400 rack.
Power-Failure Buffering
The supply buffers brief input interruptions and supports optional lithium backup for retained data.
Official Specifications
| Nominal Input Voltage | 120/230 V AC or 120/230 V DC |
|---|---|
| Permitted Input Range | 85 to 264 V AC; 88 to 300 V DC |
| Line Frequency | 50/60 Hz nominal; 47 to 63 Hz permitted |
| Rated Input Current | 0.9 A at 120 V AC; 1.0 A at 120 V DC; 0.5 A at 230 V AC or DC |
| Inrush Current | 63 A peak at 230 V AC or 58 A peak at 300 V DC, 1 ms half-value width |
| Leakage Current | Less than 3.5 mA |
| Output Voltages | 5.1 V DC and 24 V DC |
| Output Currents | 10 A at 5 V DC and 1.0 A at 24 V DC |
| Power-Failure Buffering | More than 20 ms at a 1 s repetition rate |
| Power Consumption | 95 W |
| Power Loss | 20 W |
| Backup Current | Maximum 100 µA with input power off |
| Optional Backup Battery | 1 lithium AA cell, 3.6 V / 2.2 Ah |
| Protection Class | Class I with protective conductor |
| Overvoltage Category | II |
| Pollution Degree | 2 |
| Required Rack Slots | 2 |
| Dimensions | 50 × 290 × 217 mm (W × H × D) |
| Approximate Weight | 1.2 kg |
Frequently Asked Questions
May 6ES7407-0KA02-0AA0 be supplied from either AC or DC mains?
The wide-range input accepts the documented 120/230 V nominal AC or DC sources within their permitted ranges.
How much S7-400 backplane current can 6ES7407-0KA02-0AA0 provide?
The module supplies 10 A at 5 V DC and 1.0 A at 24 V DC.
How many rack positions does 6ES7407-0KA02-0AA0 occupy?
The power supply requires two slots in the S7-400 rack.
What input protection should I consider for 6ES7407-0KA02-0AA0?
Size the upstream protection for the selected input source and the documented inrush-current pulse.
Can 6ES7407-0KA02-0AA0 bridge a short mains interruption?
The power supply provides more than 20 ms of buffering at the specified repetition rate.
Which backup battery fits 6ES7407-0KA02-0AA0?
The optional backup arrangement uses one 3.6 V lithium AA cell rated at 2.2 Ah.
What wiring check is essential before energizing 6ES7407-0KA02-0AA0?
Confirm the selected input range, protective conductor and three-conductor power connection before energizing the rack.
Compatibility & Ordering Notes
Compatibility Checklist
- Calculate the combined 5 V and 24 V rack demand before replacement.
- Confirm that the installed source is within the permitted AC or DC range.
- Preserve the rack battery strategy and verify all connectors with power isolated.