Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7332 5rd00 0ab0 sm332 ex analog output-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S7-300 6ES7332-5RD00-0AB0 SM 332 Ex Analog Output

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-300

6ES7332-5RD00-0AB0 SM 332 Ex Four-Channel Analog Output Module

Siemens 6ES7332-5RD00-0AB0 is the SIMATIC S7-300 SM 332 Ex analog output module with four isolated 0/4 to 20 mA channels, diagnostics, PTB testing and a 20-pole front connection.

At a Glance

Brand Siemens
Model 6ES7332-5RD00-0AB0
Product Type Four-channel isolated current output module for hazardous-area signals
Core Function Generates 0/4 to 20 mA analog signals with channel diagnostics
Application or Compatible Series SIMATIC S7-300 and ET 200M systems with Ex(i) field circuits

Ex Circuit Review

Confirm the hazardous-area protection concept, barriers, field devices and permitted circuit data.

Current Range

Copy the selected 0 to 20 mA or 4 to 20 mA range for each output channel.

Diagnostic Wiring

Preserve the twenty-pole connector, actuator-cable continuity and channel diagnostic parameters.

Product Overview

Siemens 6ES7332-5RD00-0AB0 is the SIMATIC S7-300 SM 332 Ex analog output module with four isolated 0/4 to 20 mA channels, diagnostics, PTB testing and a 20-pole front connection.

The module is designed for intrinsically safe analog signals from hazardous areas. Four outputs provide selectable 0 to 20 mA or 4 to 20 mA process commands. Overrange and actuator-cable wire-break monitoring are available with channel fault indication.

Ordering focus: verify the exact Ex analog-output article, intrinsic-safety design, twenty-pole connector, 24 V supply, channel current ranges, field loads, cable shielding and diagnostics.
Key Functions

Hazardous-Area Output

The module is designed for intrinsically safe analog signals from hazardous areas.

Four Current Channels

Four outputs provide selectable 0 to 20 mA or 4 to 20 mA process commands.

Channel Diagnostics

Overrange and actuator-cable wire-break monitoring are available with channel fault indication.

Official Specifications
Number of Analog Outputs 4
Output Signal Ranges 0 to 20 mA and 4 to 20 mA
Rated Load Voltage 24 V DC
Reverse-Polarity Protection Available
Maximum No-Load Current from L+ 200 mA
Maximum Backplane Current at 5 V DC 80 mA
Typical Power Loss 4 W
Maximum Current-Output No-Load Voltage 14 V
Maximum Current-Load Impedance 500 Ω
Maximum Shielded Cable Length 200 m
Maximum Resolution 15 bit including sign
Operational Error over Temperature Range ±0.55% of output range
Basic Error at 25 °C ±0.2% of output range
Diagnostic Function Available
Overrange Diagnosis Available
Actuator-Cable Wire-Break Diagnosis Available
Group Fault Indicator Red SF LED
Channel Fault Indication Red F LED
Hazardous-Area Protection Ex(i) module
Required Front Connector 20-pole
Frequently Asked Questions

Which current ranges can I configure on 6ES7332-5RD00-0AB0?

Select either zero to twenty milliamperes or four to twenty milliamperes for each output.

Is 6ES7332-5RD00-0AB0 intended for intrinsically safe circuits?

Yes, it is designed for analog output signals used with the approved hazardous-area circuit arrangement.

What load limit applies to 6ES7332-5RD00-0AB0?

Keep the connected current-loop load at or below five hundred ohms.

How can 6ES7332-5RD00-0AB0 detect a disconnected actuator cable?

Enable the available channel diagnostics so a wire break is reported through the fault indication.

Which connector is required by 6ES7332-5RD00-0AB0?

Use the specified twenty-pole front connector with the verified terminal assignment.

What should I compare before exchanging 6ES7332-5RD00-0AB0?

Compare the complete article, channel ranges, field-circuit approval, wiring, load and diagnostics.

What should I inspect if 6ES7332-5RD00-0AB0 reports overrange?

Check the configured range, loop wiring, field device, load resistance and power supply.

Compatibility & Ordering Notes
Before ordering 6ES7332-5RD00-0AB0: verify the exact Ex analog-output article, intrinsic-safety design, twenty-pole connector, 24 V supply, channel current ranges, field loads, cable shielding and diagnostics.

Compatibility Checklist

  • Confirm the existing S7-300 or ET 200M configuration contains this exact Ex output module.
  • Validate the complete intrinsic-safety circuit and field-device data before installation.
  • Retain all channel ranges, connector wiring, shields and diagnostic parameters.
Hot Selling Models
SEA41.2
0354760000
492-CB1G010
8A615.3
ASBSV8/LED-5
5SX23C10
1200661036
3RV2011-1DA20 3RV2901-2F
3RV2011-0HA15
03369.000
CG8.A004.FT2.F778 70009518
7000-12241-7320750
TKHM-W-10/LP 201710
PLC-BSC-24VDC/1IC/ACT
3VU1300-1MN00

Get a Free Quote