Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7231 4pa30 0xb0 simatic s7 1200 sb 1231 rtd signal board-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7231-4PA30-0XB0 SIMATIC S7-1200 SB 1231 RTD Signal Board

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC S7-1200

6ES7231-4PA30-0XB0 SIMATIC S7-1200 SB 1231 RTD Signal Board

A one-channel RTD signal-board arrangement with signed 16-bit conversion, platinum-sensor support and readable wire-break diagnostics.

At a Glance

Brand Siemens
Model 6ES7231-4PA30-0XB0
Product Type SB 1231 RTD signal board
Core Function Converting resistance-thermometer signals to temperature values
Application Compatible S7-1200 CPU signal-board positions

One RTD channel

The input supports platinum resistance thermometers.

Flexible engineering units

Temperature values can be configured in degrees Celsius or Fahrenheit.

Wiring diagnostics

Wire-break diagnostics and diagnostic alarms are supported.

Product Overview

6ES7231-4PA30-0XB0 provides a one-channel resistance-thermometer input in the SB 1231 signal-board format for a compatible S7-1200 CPU.

The integrating converter supports platinum RTDs, resistance and the specified low-level voltage range, while readable diagnostics help the application respond to wiring faults.

Ordering focus: Match the platinum sensor and measurement range to the supported signal-board input and the CPU installation position.
Key Functions

Acquire a platinum sensor

The input supports Pt100, Pt200, Pt500 and Pt1000 resistance-thermometer types.

Convert the selected signal range

The integrating measurement arrangement provides 15 bits plus sign and configurable temperature engineering units.

Detect wiring faults

Readable diagnostics include wire-break detection and diagnostic alarms.

Official Specifications
Input Channels 1 resistance-thermometer input
Rated Supply 24 V DC
Typical Supply Current 5 mA; 20 mA from the 5 V backplane
Typical Power Dissipation 0.5 W
Supported Platinum RTDs Pt100, Pt200, Pt500 and Pt1000
Resistance Measurement Ranges 0–150 Ω, 0–300 Ω and 0–600 Ω
Voltage Measurement Range −80 to +80 mV
Input Resistance in Millivolt Range At least 10 MΩ
Conversion Principle Integrating
Maximum Resolution 15 bits plus sign
Temperature Engineering Units Degrees Celsius or Fahrenheit
Maximum Shielded Cable Length 100 m, shielded twisted pair
Temperature Error Relative to Input Range ±0.1% at 25 °C; ±0.2% up to 55 °C
Steady-State Repeat Accuracy at 25 °C ±0.05% of range
Common-Mode Interference Rejection At least 120 dB
Wiring Diagnostics Readable wire-break diagnostics and diagnostic alarm
Operating Temperature by Mounting Direction Horizontal: −20 to +60 °C; vertical: −20 to +50 °C
Dimensions (W × H × D) 38 × 62 × 21 mm
Approximate Weight 35 g
Frequently Asked Questions

Can 6ES7231-4PA30-0XB0 read a Pt1000 resistance thermometer?

The RTD input supports Pt1000 as well as Pt100, Pt200 and Pt500 sensors.

Can I connect a 4–20 mA transmitter to 6ES7231-4PA30-0XB0?

The input does not support current measurement.

Can 6ES7231-4PA30-0XB0 acquire a thermocouple signal as a thermocouple channel?

The board does not support thermocouple measurement.

Can I display temperatures from 6ES7231-4PA30-0XB0 in Fahrenheit?

Temperature engineering units can be selected as degrees Celsius or Fahrenheit.

Will 6ES7231-4PA30-0XB0 detect a broken sensor wire?

The board supports readable wire-break diagnostics and a diagnostic alarm.

Which cable should I select for a long connection to 6ES7231-4PA30-0XB0?

Use shielded twisted-pair cable with a maximum length of 100 m.

Does vertical mounting change the temperature limit of 6ES7231-4PA30-0XB0?

The maximum ambient temperature is 50 °C vertically and 60 °C horizontally.

Compatibility & Ordering Notes
Before ordering 6ES7231-4PA30-0XB0: Select the supported platinum sensor, cable arrangement and CPU signal-board position, then configure the required engineering units and diagnostic response.

Compatibility Checklist for 6ES7231-4PA30-0XB0

  • Select Pt100, Pt200, Pt500 or Pt1000 within the supported input configuration.
  • Do not use the RTD channel as a current or thermocouple input.
  • Keep the shielded twisted-pair sensor cable within 100 m.
  • Use the vertical-mounting limit of 50 °C where applicable.
  • Process wire-break diagnostics in the application.
Hot Selling Models
NFD02.2-480-030
692.911017011
PCE 953050
1070XP
efector150 KI5092
6ES5947-3UA22
10-TWIN
ADN-16-20-IPA-S2
17940A8
IOL-102-000-K019
B&R 8BZVI0055D0.000-1A
IK7825.81 0050830
1003-12-1
Allen-Bradley 1734-IR2
0510-10-000050

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.