Overview
SIMATIC ET 200pro

6ES7194-4DD00-0AA0 ET 200pro CM IO 16 x M12 Connection Module

Sixteen M12 field sockets with grouped sensor supplies, channel wiring and shield-based functional grounding for the ET 200pro fail-safe input assembly.

At a Glance

Brand Siemens
Model 6ES7194-4DD00-0AA0
Product Type CM IO connection module
Core Function Connects field sensors through 16 M12 sockets
Application Distributed fail-safe digital input stations

Sixteen field connections

M12 sockets X1 through X16 provide the field connection points for the input assembly.

Paired-signal wiring

Double-assigned sockets X1–X4 and X9–X12 can carry paired signals for 1oo2 evaluation through one sensor cable.

Grouped sensor supplies

The connection assignment separates sensor-supply groups and provides functional grounding through the cable shield.

Product Overview

6ES7194-4DD00-0AA0 is the CM IO connection module used with the EM 8/16 F-DI DC24V PROFIsafe electronics module in a SIMATIC ET 200pro station. It provides the field-side sockets and plugs into the electronic module before being secured with screws.

The connector layout supports individual input channels and double-assigned sockets for paired sensor signals. Port labels and the separate module label help maintain a clear relationship between cabinet documentation, channel numbers and field wiring.

Ordering focus: Match the CM IO to EM 8/16 F-DI DC24V PROFIsafe, then check the selected sensor evaluation, paired-channel wiring and sensor-supply group.
Key Functions

Sixteen field connections

M12 sockets X1 through X16 provide the field connection points for the input assembly.

Paired-signal wiring

Double-assigned sockets X1–X4 and X9–X12 can carry paired signals for 1oo2 evaluation through one sensor cable.

Grouped sensor supplies

The connection assignment separates sensor-supply groups and provides functional grounding through the cable shield.

Official Specifications
Field connectors 16 M12 circular sockets, X1–X16
Primary sensor-supply pin Pin 1: Vs1 at X1–X4; Vs2 at X5–X8; Vs3 at X9–X12; Vs4 at X13–X16
Sensor-supply ground Pin 3: 1M
Primary signal assignment Pin 4: input channels 0–15 at X1–X16 respectively
Secondary signal assignment Pin 2 at X1–X4: channels 4–7; pin 2 at X9–X12: channels 12–15
Functional grounding Through the cable shield
Connection cable 3-, 4- or 5-core copper cable, according to the required assignment
Identification labels 16 port labels and one module label
Dimensions (W × H × D) 90 × 130 × 39 mm
Weight 505 g
Frequently Asked Questions

Which electronics module accepts 6ES7194-4DD00-0AA0?

The connection module mates with the EM 8/16 F-DI DC24V PROFIsafe electronic module.

How many M12 field sockets are available on 6ES7194-4DD00-0AA0?

There are sixteen sockets, identified as X1 through X16.

Which sockets on 6ES7194-4DD00-0AA0 support paired input signals?

Sockets X1–X4 and X9–X12 are double assigned, allowing paired signals to be wired through one cable for 1oo2 evaluation.

Where does input channel 0 connect on 6ES7194-4DD00-0AA0?

Channel 0 is assigned to pin 4 of socket X1.

Which pin provides the sensor-supply return on 6ES7194-4DD00-0AA0?

Pin 3 is the 1M sensor-supply ground connection.

How is functional ground carried through 6ES7194-4DD00-0AA0?

Functional grounding is provided through the shield, so the shield connection must be included in the installation plan.

How is 6ES7194-4DD00-0AA0 attached to the station?

Plug the connection module onto its matching electronics module and secure the assembly with the specified screws.

Compatibility & Ordering Notes
Before ordering 6ES7194-4DD00-0AA0: Match the CM IO to EM 8/16 F-DI DC24V PROFIsafe, then check the selected sensor evaluation, paired-channel wiring and sensor-supply group.

Before installation

  • Use the connection assignment for EM 8/16 F-DI DC24V PROFIsafe and the selected 1oo1 or 1oo2 evaluation.
  • Check secondary pin assignments before using a double-assigned socket; pin 2 and pin 5 assignments depend on the socket group.
  • Keep sensor supplies and 1M returns associated with the correct group, and terminate the shield for functional grounding.
  • Apply all port and module labels, then check the mechanical connection and screws before commissioning.
Hot Selling Models
6ES5095-8MD01
3NE8021-1
Allen-Bradley 1734-OB8 + 1734-RTBS
FX3-CPU320002 1059305
63A 0.03A
FLK-D37
29722 A9713 01088
E2J-JC4A
NZ1VZ-538EL060-M
2.5-TWIN 3031241
734-001 734001 51223646
E4 24DC/1-4A
RJCS1A60D50EPPO
6ES5304-3UA12
RAK112.0040

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.