Siemens SIMATIC ET 200MP 6ES7155-5BA00-0AB0 IM 155-5 DP ST
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SIMATIC ET 200MP
6ES7155-5BA00-0AB0 IM 155-5 DP ST Interface Module
Siemens 6ES7155-5BA00-0AB0 is the SIMATIC ET 200MP IM 155-5 DP ST interface module for connecting up to twelve S7-1500 I/O modules to PROFIBUS DP at rates up to 12 Mbit/s.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7155-5BA00-0AB0 |
| Product Type | PROFIBUS DP interface module for distributed I/O |
| Core Function | Connects an ET 200MP station to a PROFIBUS DP master |
| Application or Compatible Series | SIMATIC ET 200MP stations with S7-1500 I/O modules |
Station Layout
Confirm the rack contains no more than twelve permitted S7-1500 I/O modules in the saved order.
Bus Identity
Preserve the PROFIBUS address, GSD revision, segment rate and termination arrangement.
Power Budget
Check the 24 V supply, inrush demand and fourteen-watt backplane power limit.
Product Overview
Siemens 6ES7155-5BA00-0AB0 is the SIMATIC ET 200MP IM 155-5 DP ST interface module for connecting up to twelve S7-1500 I/O modules to PROFIBUS DP at rates up to 12 Mbit/s.
One isolated RS485 interface links the ET 200MP station to a DP master. The interface module operates an ET 200MP rack with up to twelve I/O modules. RUN, ERROR and MAINT indicators plus DPV1 diagnostics support commissioning and service.
Key Functions
PROFIBUS DP Connection
One isolated RS485 interface links the ET 200MP station to a DP master.
S7-1500 I/O Support
The interface module operates an ET 200MP rack with up to twelve I/O modules.
Integrated Diagnostics
RUN, ERROR and MAINT indicators plus DPV1 diagnostics support commissioning and service.
Official Specifications
| Hardware Functional Status | FS01 or later |
|---|---|
| Firmware Version | V2.0.0 |
| Vendor Identification | 81AAh |
| Identification and Maintenance Data | I&M0 through I&M3 |
| Minimum TIA Portal Integration | Version 13 |
| GSD Version and Revision | V1.0 and V5.1 |
| Rated Supply Voltage | 24 V DC |
| Permitted Supply Range | 19.2 to 28.8 V DC |
| Voltage-Failure Buffer Time | 5 ms |
| Rated No-Load Current at 24 V DC | 0.2 A |
| Maximum Current Consumption | 1.2 A at 20.4 V DC |
| Maximum Inrush Current | 4 A |
| Inrush Energy | 0.09 A²·s |
| Maximum Current from 5 V Interface | 80 mA |
| Backplane-Bus Infeed Power | 14 W |
| Maximum I/O Modules per Rack | 12 |
| PROFIBUS Interface | 1 RS485 port |
| Maximum PROFIBUS Rate | 12 Mbit/s |
| Permitted Circuit Potential Difference | 75 V DC or 60 V AC |
| Insulation Test Voltage | 707 V DC |
Frequently Asked Questions
How many I/O modules can I install behind 6ES7155-5BA00-0AB0?
The ET 200MP station may contain up to twelve permitted I/O modules.
Which PROFIBUS speed can 6ES7155-5BA00-0AB0 use?
The RS485 interface supports a segment rate up to twelve megabits per second.
What engineering version supports 6ES7155-5BA00-0AB0?
The interface module is integrated in TIA Portal from version thirteen or can be configured through the applicable GSD file.
What must be copied before replacing 6ES7155-5BA00-0AB0?
Copy the PROFIBUS address, rack order, module parameters, GSD assignment and diagnostic configuration.
How should I size the supply for 6ES7155-5BA00-0AB0?
Allow for the normal current, maximum load current, four-ampere inrush and backplane power demand.
What do the LEDs on 6ES7155-5BA00-0AB0 indicate?
Green RUN, red ERROR and yellow MAINT indicators show the principal operating and service states.
Can I replace I/O modules while 6ES7155-5BA00-0AB0 is operating?
No, this standard interface module does not provide hot-swapping of the connected modules.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm the saved ET 200MP rack contains no more than twelve compatible S7-1500 I/O modules.
- Retain the PROFIBUS address, GSD revision, station parameters, segment rate and termination.
- Check the supply and backplane power budget before reconnecting the station.