Siemens SIMATIC ET 200iSP IM 152-1DP Interface Module 6ES7152-1AA00-0AB0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMATIC ET 200iSP

6ES7152-1AA00-0AB0 SIMATIC ET 200iSP IM 152-1DP Interface Module

The IM 152-1DP connects ET 200iSP distributed I/O to intrinsically safe PROFIBUS DP through an RS 485-IS coupler and supports standard or redundant H-system operation.

At a Glance

Brand Siemens
Model 6ES7152-1AA00-0AB0
Product Type intrinsically safe PROFIBUS DP interface module
Core Function Connects ET 200iSP electronic modules to PROFIBUS RS 485-IS
Application or Compatible Series ET 200iSP process I/O stations in standard or redundant PROFIBUS systems

Exact Identification

Match 6ES7152-1AA00-0AB0 character by character and confirm the complete SIMATIC ET 200iSP IM 152-1DP Interface Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The IM 152-1DP connects ET 200iSP distributed I/O to intrinsically safe PROFIBUS DP through an RS 485-IS coupler and supports standard or redundant H-system operation.

The interface operates on the PROFIBUS RS 485-IS segment behind the required coupler. Supported firmware permits redundant use in an H system. The module forms the communication interface for ET 200iSP standard and fail-safe electronic modules.

Ordering focus: confirm PROFIBUS address, standard or redundant mode, firmware release, RS 485-IS coupler, segment termination and ET 200iSP module compatibility.
Key Functions

Intrinsically Safe Bus Link

The interface operates on the PROFIBUS RS 485-IS segment behind the required coupler.

Redundant System Support

Supported firmware permits redundant use in an H system.

Hazardous-Area I/O

The module forms the communication interface for ET 200iSP standard and fail-safe electronic modules.

Official Specifications
Interface Type PROFIBUS DP via RS 485-IS
Distributed I/O System SIMATIC ET 200iSP
RS 485-IS Coupler Required
Standard Operation Supported
Redundant H-System Operation Supported with released firmware
Maximum Stations per S1/S2 Segment 31
Maximum Stations per R1 Segment 32
Engineering Baseline STEP 7 V5.4 SP1 with current hardware update
Fail-Safe Module Support Supported with released firmware
Terminal Module TM-IM/EM with terminating module
Hazardous-Area Enclosure Ex e enclosure required for Zone 1 installation
Frequently Asked Questions

Which fieldbus connects to 6ES7152-1AA00-0AB0?

It connects an ET 200iSP station through intrinsically safe PROFIBUS DP.

Is an RS 485-IS coupler required for 6ES7152-1AA00-0AB0?

Yes; the coupler provides the intrinsically safe PROFIBUS segment.

Can 6ES7152-1AA00-0AB0 operate redundantly in an H system?

Yes; redundant operation is supported with the released firmware and configuration.

How many ET 200iSP stations can share an S1 or S2 segment with 6ES7152-1AA00-0AB0?

The stated maximum is 31 stations per RS 485-IS segment.

Which STEP 7 baseline applies to 6ES7152-1AA00-0AB0?

Use STEP 7 V5.4 SP1 with the current hardware update.

Can fail-safe ET 200iSP modules operate behind 6ES7152-1AA00-0AB0?

Yes; released fail-safe modules are supported with the required firmware levels.

What must be checked before replacing 6ES7152-1AA00-0AB0?

Verify address, redundancy mode, firmware, coupler, termination, module release and the PROFIBUS project.

Compatibility & Ordering Notes
Before ordering 6ES7152-1AA00-0AB0: confirm PROFIBUS address, standard or redundant mode, firmware release, RS 485-IS coupler, segment termination and ET 200iSP module compatibility.

Compatibility Checklist

  • Retain the PROFIBUS address, bus parameters and redundant-system configuration.
  • Verify the RS 485-IS coupler and switchable termination before energizing the segment.
  • Confirm that every standard and fail-safe electronic module is released for the interface firmware.
Hot Selling Models
5SY4104-5
PLC-BSC-24UC/21-21
3SB3 201-0AA11
CPE18-M1H-3GL-1/4
SV9340.710
ABB S203 MC 20 2CD S273 001 R0204
ST-REL2-KG
3RT1023-1AP00 3RH1921-1CA01
010.05-1s
Allen. Bradley 1585J-M4TBJM-1
3RT1015-1BB41
3RT1926-1ER00
6ES7122-1BB00-0AA0
LADR2
CPV14GEMP6

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.