siemens 6es7141 4bh00 0aa0 simatic et 200pro 16 channel digital input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7141-4BH00-0AA0 SIMATIC ET 200pro 16-Channel Digital Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200pro

6ES7141-4BH00-0AA0 SIMATIC ET 200pro 16-Channel Digital Input Module

A sixteen-input electronics module with sensor-supply diagnostics, per-channel indication and an included bus module.

At a Glance

Brand Siemens
Model 6ES7141-4BH00-0AA0
Product Type Field digital input electronics
Core Function Collecting machine switching states
Application ET 200pro distributed stations

Sixteen field input points

Positive-reading inputs collect standard 24 V DC switching states.

Sensor supply supervision

Electronic sensor-supply protection and module-level short-circuit diagnostics monitor the field supply.

Visible channel status

Individual green input indicators accompany a red group-error indication.

Product Overview

6ES7141-4BH00-0AA0 collects DC switching signals in an ET 200pro station.

The electronics module includes its bus module, while the separate IO connection module provides the field connections; sensor-supply diagnostics and local channel LEDs support maintenance.

Ordering focus: Match the separate IO connection module, positive-reading sensor signals, supply demand and field-cable lengths.
Key Functions

Sixteen field input points

Positive-reading inputs collect standard 24 V DC switching states.

Sensor supply supervision

Electronic sensor-supply protection and module-level short-circuit diagnostics monitor the field supply.

Visible channel status

Individual green input indicators accompany a red group-error indication.

Official Specifications
Rated supply 24 V DC
Maximum electronics current 30 mA from 1L+ and 20 mA from the 3.3 V backplane
Sensor supply outputs 8; maximum stated output current 1 A up to 55 °C
Sensor supply protection Electronic short-circuit protection per module
Typical power loss 3 W
Input address allocation 2 bytes
Digital inputs 16 positive-reading channels, IEC 61131 type 1
Simultaneously active inputs 16 up to 55 °C in all mounting positions
Low and high signal levels Low: −3 to +5 V; high: +11 to +30 V
Typical high-state input current 4 mA
Rising-edge delay 1.2–4.8 ms
Falling-edge delay 0.7–3 ms
Delay adjustment Not parameterizable
Maximum unshielded cable 30 m
Two-wire sensor quiescent current Maximum 1.5 mA
Diagnostics Readable diagnostic data, diagnostic alarm and module-level sensor-supply short circuit
Status indication Red SF and a green indicator for each input
Isolation Inputs isolated from backplane; no channel-to-channel isolation
Isolation type test 707 V DC
Dimensions and mass 45 × 130 × 35 mm; approximately 140 g
Frequently Asked Questions

Is the IO connection module included with 6ES7141-4BH00-0AA0?

The bus module is included, while IO connection module 6ES7194-4CB50-0AA0 is ordered separately.

How many input bytes should I allocate to 6ES7141-4BH00-0AA0?

The electronics module occupies two input bytes.

Can a two-wire sensor be connected to 6ES7141-4BH00-0AA0?

Two-wire sensors are permitted with a maximum quiescent current of 1.5 mA.

Can I parameterize a different standard input delay on 6ES7141-4BH00-0AA0?

The standard input delays are fixed rather than parameterizable.

Does 6ES7141-4BH00-0AA0 protect the sensor supply individually for every channel?

Sensor-supply electronic protection and short-circuit diagnostics operate at module level.

Can I use more than 30 m of unshielded field wiring with 6ES7141-4BH00-0AA0?

The specified maximum unshielded cable length is 30 m.

Can I see the state of each input directly on 6ES7141-4BH00-0AA0?

Each input has its own green status indicator.

Compatibility & Ordering Notes
Before ordering 6ES7141-4BH00-0AA0: Match the separate IO connection module, positive-reading sensor signals, supply demand and field-cable lengths.

Before installation

  • Order the specified IO connection module separately from the electronics module.
  • Use positive-reading sensors within the stated signal and quiescent-current limits.
  • Plan both electronics supply demand and the sensor-supply arrangement.
  • Observe fixed input response times and the maximum unshielded field-cable length.
Hot Selling Models
1461000 16DX12HUB 500
KMPPE-B-5
60.001.383 2C3800L02-LT
E3RB-RP11
BK3100
MGB-A-MOUNTINGPLATE-L-109490
HM250/300 128624
FSF050A9088
PTK-4 PSMPTK-4 27
332G127 PN400
KHD2-OT1/Ex2 21070S
R112186000
13A1056.3
6ES5458-7LB11
7PA1020-6EA

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.