siemens 6es7138 7fd00 0ab0 simatic et200isp 4 f do ex module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC ET 200iSP 6ES7138-7FD00-0AB0 4 F-DO Ex Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC ET 200iSP

6ES7138-7FD00-0AB0 4 F-DO Ex 17.4 V/40 mA Module

Siemens 6ES7138-7FD00-0AB0 is a four-channel fail-safe ET 200iSP transistor output module for intrinsically safe actuators, with PP switching, output readback testing and channel diagnostics.

At a Glance

Brand Siemens
Model 6ES7138-7FD00-0AB0
Product Type Fail-Safe Intrinsically Safe Digital Output Module
Core Function Controls four Ex i actuators with PP switching and safety diagnostics
Application or Compatible Series SIMATIC ET 200iSP safety stations for hazardous-area field devices

Exact Output Application

Connect only compatible intrinsically safe solenoid valves, DC relays or actuators within the documented output limits.

Safety Parameter Match

Restore the F-address, PROFIsafe settings, light-test time and readback time from the validated safety project.

Channel Pairing

Parallel only channels 0 and 1 or channels 2 and 3 on the same module using the prescribed terminal arrangement.

Product Overview

Siemens 6ES7138-7FD00-0AB0 is a four-channel fail-safe ET 200iSP transistor output module for intrinsically safe actuators, with PP switching, output readback testing and channel diagnostics.

Four intrinsically safe PP-switching channels control compatible solenoid valves, relays and field actuators. Configurable light-test and dark-test monitoring checks the safe behavior of each output. Selected channel pairs may be connected in parallel according to the specified terminal arrangement.

Ordering focus: confirm the exact ET 200iSP fail-safe module, terminal module, Ex loop calculation, actuator load, F-address, PROFIsafe settings, light-test and readback timing and any channel pairing.

Key Functions

Hazardous-Area Actuator Control

Four intrinsically safe PP-switching channels control compatible solenoid valves, relays and field actuators.

Output Readback Testing

Configurable light-test and dark-test monitoring checks the safe behavior of each output.

Channel Pairing for Higher Power

Selected channel pairs may be connected in parallel according to the specified terminal arrangement.

Official Specifications

Permissible DC Supply Range 19.2 to 30 V DC
Typical Current Consumption 340 mA
Maximum L+ Current without Load 510 mA through the internal power bus
Maximum Power Loss 5.3 W
Output Technology Transistor, PP-switching
Number of Outputs 4
Maximum Signal-1 Output Voltage 17.4 V DC
Rated Output Current 40 mA
Maximum Signal-0 Residual Current 10 µA
Internal Resistance 167 Ω
Permissible Load Resistance 270 Ω to 18 kΩ
Parallel Output Pairs Channels 0 and 1 or channels 2 and 3 on the same module
Diagnostic Monitoring Short circuit, overload and wire break
Indicators SF, SAFE and per-channel green/red status or fault LEDs
Maximum Safety Classification SIL 3, Performance Level e and Category 4
Response-Time Formula 9 ms plus the greater of the configured light-test time or dark-test readback time
Cycle-Time Formula 7 ms plus the configured light-test time
Electrical Connection Screw or spring-loaded terminal
Dimensions 30 × 129 × 136.5 mm

Frequently Asked Questions

Which actuators can be connected to 6ES7138-7FD00-0AB0?

Compatible loads include intrinsically safe solenoid valves, DC relays and other Ex i actuators within the stated output limits.

Can outputs on 6ES7138-7FD00-0AB0 be connected in parallel?

Only channels 0 and 1 or channels 2 and 3 may be paired on the same module using the prescribed terminals.

What safety level can 6ES7138-7FD00-0AB0 achieve?

A correctly designed system can reach SIL 3, Performance Level e and Category 4.

What supply range is required by 6ES7138-7FD00-0AB0?

The permitted supply range is 19.2 to 30 V DC through the ET 200iSP power arrangement.

How much current can each channel of 6ES7138-7FD00-0AB0 deliver?

Each output is rated for a maximum of 40 mA at the specified intrinsically safe characteristic.

Which faults are monitored by 6ES7138-7FD00-0AB0?

The module monitors short circuit, overload and wire break and reports status through LEDs and assignable diagnostics.

What must be checked before replacing 6ES7138-7FD00-0AB0?

Confirm the terminal module, Ex circuit parameters, F-address, safety parameters, channel pairing and actuator load before recommissioning.

Compatibility & Ordering Notes

Before ordering 6ES7138-7FD00-0AB0: confirm the exact ET 200iSP fail-safe module, terminal module, Ex loop calculation, actuator load, F-address, PROFIsafe settings, light-test and readback timing and any channel pairing.

Compatibility Checklist

  • Confirm the ET 200iSP interface module, terminal module, power bus and project hardware entry.
  • Verify the complete intrinsically safe loop, actuator parameters, cable values and applicable hazardous-area approval.
  • Match the F-address, PROFIsafe settings and validated safety program.
  • Retain the configured light-test and dark-test readback times.
  • Parallel only channels 0 and 1 or channels 2 and 3 on the same module.
  • Verify the actuator current and load resistance before energizing the output.
Hot Selling Models
W3120000411
SMT-8M-A-PS-24V-E-1-M8D
CLH3X
BES01AY BES 516-325-AO-C-PU-05
S29-5MPUR
BOS0012 BOS12M-PS-1YA-S4-C
NEBL-M8G4-E-2-N-M8G4
3RV1021-4BA10
3RT1025-1BB40 3RH1921-1FA22 3RT1926-1BB00
IM5134 IMC4035-CPKG/US
GV2ME06 GVAN11
EQ72KL 684.120.2000
G122 0025 R 0102
2507.500
Festo 539182

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.