Overview
SIMATIC ET 200S

6ES7138-4DC01-0AB0 ET 200S 1 STEP Stepper Positioning Module

Single-channel stepper positioning module with a 5 V/204 kHz interface, RS422 differential pulse/direction signals and two digital inputs.

At a Glance

Brand Siemens
Model 6ES7138-4DC01-0AB0
Product Type Single-axis stepper positioning module
Core Function Pulse-and-direction command generation
Application ET 200S external stepper power stages

Differential step commands

PULSE/notPULSE and DIR/notDIR signals connect to an RS422-compatible stepper power stage.

Machine reference and stop inputs

Two digital inputs can serve reference cams, pulse suppression, an external stop or limit switches.

Local motion status

RDY, POS, SF and input-state LEDs support positioning and wiring checks.

Product Overview

6ES7138-4DC01-0AB0 generates pulse and direction commands for an external stepper motor power unit from an ET 200S station.

Two 24 V digital inputs support functions such as reference cam, pulse suppression, external stop and limit switch, while dedicated indicators show readiness, positioning mode and group fault.

Ordering focus: Match the external power stage to differential RS422 pulse/direction signals and keep the stepper interface cable within 100 m.
Key Functions

Differential step commands

PULSE/notPULSE and DIR/notDIR signals connect to an RS422-compatible stepper power stage.

Machine reference and stop inputs

Two digital inputs can serve reference cams, pulse suppression, an external stop or limit switches.

Local motion status

RDY, POS, SF and input-state LEDs support positioning and wiring checks.

Official Specifications
Load Supply 24 V DC with reverse-polarity protection
Typical Load-Supply Current 40 mA without load
Maximum Backplane Consumption 10 mA from 3.3 V DC
Typical Power Loss 1.5 W
Stepper Command Interface 5 V differential RS422 pulse and direction
Maximum Pulse Frequency 204 kHz
Digital Inputs 2 inputs; 24 V DC nominal
Input Signal Levels Signal 0: −30 to +5 V; signal 1: +11 to +30 V
Typical High-State Input Current 9 mA
Maximum Input Delay 4 ms for either transition
Maximum Input Repeat Frequency 100 Hz
Maximum Digital Input Cable 1,000 m shielded; 600 m unshielded
Maximum Stepper Interface Cable 100 m, twisted and shielded in pairs
Dimensions and Approximate Weight 15 × 81 × 52 mm; 40 g
Frequently Asked Questions

Can 6ES7138-4DC01-0AB0 drive the motor windings directly?

The module sends pulse and direction commands to an external stepper power unit.

Which command interface must the power stage accept for 6ES7138-4DC01-0AB0?

The power stage must accept RS422 differential PULSE/notPULSE and DIR/notDIR signals.

How long can the stepper command cable be for 6ES7138-4DC01-0AB0?

The command cable can extend up to 100 m when the conductors are twisted and shielded in pairs.

Can I connect a reference cam to 6ES7138-4DC01-0AB0?

The digital inputs support reference-cam functions as well as pulse suppression, external stop and limit-switch functions.

What input voltage should I use for stop and reference signals on 6ES7138-4DC01-0AB0?

The digital inputs are designed for 24 V DC signals with a high-state range of +11 to +30 V.

Which indicators help me troubleshoot positioning on 6ES7138-4DC01-0AB0?

The module provides RDY, green POS, red SF and green digital-input indicators.

How many motion axes can 6ES7138-4DC01-0AB0 command?

The module provides one stepper motor positioning channel.

Compatibility & Ordering Notes
Before ordering 6ES7138-4DC01-0AB0: Match the external power stage to differential RS422 pulse/direction signals and keep the stepper interface cable within 100 m.

Before installation

  • Select an external power unit with a differential RS422 pulse-and-direction interface.
  • Keep the motor-command cable within 100 m and use paired twisted shielding.
  • Assign the two digital inputs to the required reference or stop functions in the project.
  • Provide the 24 V DC load supply and allow for the 15 mm module width.
Hot Selling Models
PKZM0-12 XTPR012BC1
efector200 E20842
582180-01
CL100-E 048552-106
5SY6625-7
X20BC0083
54.808.106D53
6GK5 208-0BA00-2AF2 6GK1900-0AB00
IK7825 IK7825.81 0043110
ST1H-PB
SI-232/J
3RK1400-1MQ03-0AA4
CPX-8DE CPX-AB-8-M8-3PIN
AD/CT8303
PRK85/4 00227

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.