Siemens 6ES7137-6AA00-0BA0 SIMATIC ET 200SP CM PtP Serial Communication Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Select the same physical interface, protocol role and character framing at both communication endpoints.
- Use TIA Portal V12 or later, or STEP 7 V5.5 SP2 with the applicable GSD.
- PROFIBUS engineering requires GSD revision 5 or later; PROFINET requires GSDML V2.3.
- Apply the extended low-temperature range only to hardware FS03 and later, and retain the orientation-dependent upper limit.
6ES7137-6AA00-0BA0 SIMATIC ET 200SP CM PtP Serial Communication Module
A CM PtP module with RS232, RS422 and RS485 interfaces, transfer rates up to 115.2 kbit/s and integrated Freeport, 3964(R), USS and Modbus RTU protocols.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7137-6AA00-0BA0 |
| Product Type | Serial communication electronics module |
| Core Function | Exchanging telegrams with serial field devices |
| Application | ET 200SP distributed I/O stations |
Select the serial physical interface
RS232, RS422 and RS485 are available at rates up to 115.2 kbit/s, including four-wire full-duplex and multipoint RS422 operation.
Exchange protocol telegrams
Integrated protocols include Freeport, 3964(R), USS and Modbus RTU master or device operation.
Buffer and diagnose reception
The 4 kB telegram buffer holds up to 255 telegrams, with separate RxD, TxD, power and diagnostic indications.
Product Overview
6ES7137-6AA00-0BA0 connects serial devices to an ET 200SP station. The communication module supports RS232, RS422 or RS485 electrical interfaces and can operate with the selected integrated telegram protocol.
A receive buffer stores incoming telegrams for processing by the controller. Diagnostic, power, receive and transmit indicators separate module health from line activity, and the serial interface is isolated from the backplane.
Key Functions
Select the serial physical interface
RS232, RS422 and RS485 are available at rates up to 115.2 kbit/s, including four-wire full-duplex and multipoint RS422 operation.
Exchange protocol telegrams
Integrated protocols include Freeport, 3964(R), USS and Modbus RTU master or device operation.
Buffer and diagnose reception
The 4 kB telegram buffer holds up to 255 telegrams, with separate RxD, TxD, power and diagnostic indications.
Official Specifications
| Supply rating and range | 24 V DC; 19.2–28.8 V DC |
|---|---|
| Rated current consumption | 29 mA |
| Typical power loss | 0.7 W |
| Input address allocation | 8 bytes |
| Serial interface standards | RS232, RS422 and RS485 |
| Maximum serial transfer rate | 115.2 kbit/s |
| RS232 connection | Maximum 15 m; RTS, CTS, DTR, DSR, RI and DCD auxiliary signals |
| RS422 and RS485 cable length | Maximum 1,200 m |
| RS422 wiring modes | 4-wire full duplex and 4-wire multipoint |
| Integrated protocols | Freeport, 3964(R), USS, Modbus RTU master and device |
| Freeport and 3964(R) framing | 7 or 8 data bits; 1 or 2 stop bits; none, even, odd, fixed-1, fixed-0 or any parity |
| Maximum Freeport and 3964(R) telegram length | 2 kB |
| Telegram buffer resources | 4 kB; up to 255 buffered telegrams |
| Modbus RTU standard address range | 1–247 |
| Maximum Modbus RTU master device count | 32 |
| Interface isolation | Backplane-to-interface isolation, type-tested at 707 V DC |
| Operating temperature from hardware FS03 | −30 to +60 °C horizontal; −30 to +50 °C vertical |
| Maximum installation altitude | 2,000 m |
| Status indications | Green PWR, RxD and TxD LEDs; green/red DIAG LED |
| Dimensions and approximate mass | 15 × 73 × 58 mm; 30 g |
Frequently Asked Questions
Can 6ES7137-6AA00-0BA0 operate as a Modbus RTU master or slave?
The module supports both Modbus RTU master and device roles.
How many serial devices can the Modbus master on 6ES7137-6AA00-0BA0 serve?
Modbus RTU master operation supports up to 32 devices.
Can I use four-wire full-duplex RS422 with 6ES7137-6AA00-0BA0?
The RS422 interface supports four-wire full-duplex and multipoint connections.
How does the cable-length limit change between RS232 and RS485 on 6ES7137-6AA00-0BA0?
RS232 is limited to 15 m, while RS485 permits up to 1,200 m.
What receive queue is available in 6ES7137-6AA00-0BA0?
The receive buffer provides 4 kB and can store up to 255 telegrams.
Can I configure 6ES7137-6AA00-0BA0 from classic STEP 7 instead of TIA Portal?
Classic STEP 7 V5.5 SP2 or later can configure the module using the applicable GSD file.
Can 6ES7137-6AA00-0BA0 be used at a −30 °C ambient temperature?
Operation down to −30 °C is available from hardware functional status FS03.