Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7134 6jd00 0ca1 simatic et 200sp four channel rtd tc high feature input-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7134-6JD00-0CA1 SIMATIC ET 200SP Four-Channel RTD/TC High Feature Input

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200SP

6ES7134-6JD00-0CA1 SIMATIC ET 200SP Four-Channel RTD/TC High Feature Input

A four-channel High Feature module for RTDs, thermocouples, resistance and low-voltage signals, with per-channel diagnostics and RUN reparameterization.

At a Glance

Brand Siemens
Model 6ES7134-6JD00-0CA1
Product Type Universal temperature input module
Core Function Converting thermal and resistance measurements
Application ET 200SP stations with A0 or A1 BaseUnits

Multiple sensor technologies

RTDs, thermocouples, resistors and bipolar low-voltage inputs share the configurable acquisition platform.

RUN adjustment and calibration

Reparameterization and calibration can be performed in RUN for supported configuration changes.

Channel-level condition reporting

Quality information, wire-break and range diagnostics accompany configurable limit alarms.

Product Overview

6ES7134-6JD00-0CA1 combines multiple temperature-sensor technologies in a four-channel ET 200SP module.

Two-, three- and four-wire resistance connections, selectable compensation sources and scalable measuring ranges support the configured field measurement without forcing one sensor technology across the entire application.

Ordering focus: Match the sensor ranges, A0 or A1 BaseUnit, compensation method, quality-information address and engineering hardware support.
Key Functions

Multiple sensor technologies

RTDs, thermocouples, resistors and bipolar low-voltage inputs share the configurable acquisition platform.

RUN adjustment and calibration

Reparameterization and calibration can be performed in RUN for supported configuration changes.

Channel-level condition reporting

Quality information, wire-break and range diagnostics accompany configurable limit alarms.

Official Specifications
Input count 4
Resolution 16 bits including sign for voltage and temperature; 15 bits for resistance ranges
Supply voltage 24 V DC nominal; 19.2–28.8 V range
Supply current 34 mA rated; 35 mA maximum
Typical power loss 0.75 W
Input address use 8 bytes plus 1 byte for quality information
Voltage ranges ±1 V, ±250 mV, ±80 mV and ±50 mV
RTD types Cu10; Ni100, Ni120, Ni200, Ni500, Ni1000, LG-Ni1000; Pt100, Pt200, Pt500 and Pt1000
Thermocouple types B, C, E, J, K, L, N, R, S, T, U and TXK/TXK(L)
Resistance ranges 0–150, 0–300, 0–600, 0–3,000 and 0–6,000 Ω; PTC
Input impedance 1 MΩ
Typical resistance-sensor excitation 0.7 mA; 1.7 mA for Cu10
Temperature units °C, °F or K
Maximum shielded cable 200 m; 50 m for thermocouples
Digital smoothing Four levels: none, 4×, 8× and 16× conversion time
Voltage and resistance accuracy ±0.05% basic at 25 °C; ±0.1% operational limit
Additional diagnostic conversion time 2 ms for wire-break check; additional 2 ms power-line check for 3-/4-wire resistance sensors
Input isolation No channel-to-channel isolation; isolated from backplane and electronics supply
Isolation test 707 V DC type test
Channel alarms Two upper and two lower limits; wire-break and overflow/underflow diagnostics
Frequently Asked Questions

Which BaseUnit families can I use with 6ES7134-6JD00-0CA1?

The module is suitable for BaseUnit types A0 and A1.

Which BaseUnit enables the internal thermocouple reference junction on 6ES7134-6JD00-0CA1?

Internal reference-junction compensation uses a type A1 BaseUnit.

Does three-wire line compensation affect the cycle time of 6ES7134-6JD00-0CA1?

Three-wire line compensation requires an additional acquisition cycle.

Does a Cu10 sensor use the ordinary excitation current on 6ES7134-6JD00-0CA1?

Cu10 sensors use a typical 1.7 mA excitation current rather than the ordinary 0.7 mA.

Can I calibrate or reparameterize 6ES7134-6JD00-0CA1 while the station is in RUN?

Both calibration and reparameterization are supported in RUN.

Is eight bytes enough address space when I use quality information from 6ES7134-6JD00-0CA1?

Quality information requires an additional byte alongside the eight bytes of input data.

Can I use the full 200 m shielded cable allowance for a thermocouple on 6ES7134-6JD00-0CA1?

Thermocouple wiring is limited to 50 m even though other supported shielded sensor circuits permit up to 200 m.

Compatibility & Ordering Notes
Before ordering 6ES7134-6JD00-0CA1: Match the sensor ranges, A0 or A1 BaseUnit, compensation method, quality-information address and engineering hardware support.

Before installation

  • Select an A0 or A1 BaseUnit and the appropriate CC00 color coding.
  • Configure the sensor range, compensation source and wiring method for each channel.
  • Reserve the additional quality-information byte and include diagnostic checks in the cycle-time calculation.
  • For FS22 hardware with V3.0.0 firmware, use TIA Portal V21 with HSP0495 or integrated support from V21.1, or STEP 7 V5.7 SP3 HF3 with HSP0348 V2.0 or integrated support from V5.8.
Hot Selling Models
PSR-PC40-2NO-1DO-24DC-SP
3004388
B1112075
D-F7K
340407
Allen-Bradley 140M-F8E 140M-F8E-C20
UKH 240
GWR02 X2200.000.00.00
GWR-02 K.X2200.000.00.00
LC1D38 LA1DX11
QPDH4PE6.0BKLE
6ES7365-0BA01-0AA0
TS 8800.190
7PA1110-5DA
XTCE065D

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop