- Select current-mode transmitters and the matching two-wire or four-wire connection.
- Match the BaseUnit type and CC03 identification before installation.
- Include sensor-supply current, transmitter burden and input voltage drop in the loop calculation.
- Choose integration, smoothing and enabled diagnostics to suit the process response.
6ES7134-6GD00-0BA1 SIMATIC ET 200SP AI 4xI 2-/4-wire ST
Four differential current inputs with sixteen-bit conversion, selectable current ranges, module diagnostics and BaseUnit type A0 or A1 compatibility.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7134-6GD00-0BA1 |
| Product Type | Analog current input module |
| Core Function | Four-channel current acquisition |
| Application | ET 200SP stations with two- or four-wire transmitters |
Current transmitter acquisition
Four differential channels accept the stated unipolar and bipolar current ranges.
Noise and signal filtering
Selectable integration and smoothing settings adapt the measurement response to the installation.
Module and signal diagnostics
Diagnostic alarms report supply conditions, range errors and the specified wire-break and short-circuit conditions.
Product Overview
6ES7134-6GD00-0BA1 acquires four current signals from two-wire or four-wire transmitters in a SIMATIC ET 200SP station.
The module combines integrating conversion, selectable interference suppression and smoothing with diagnostics for supply, wire-break and range conditions.
Key Functions
Current transmitter acquisition
Four differential channels accept the stated unipolar and bipolar current ranges.
Noise and signal filtering
Selectable integration and smoothing settings adapt the measurement response to the installation.
Module and signal diagnostics
Diagnostic alarms report supply conditions, range errors and the specified wire-break and short-circuit conditions.
Official Specifications
| BaseUnit compatibility and color code | BU type A0 or A1; CC03 |
|---|---|
| Supply voltage | 24 V DC; permitted 19.2–28.8 V DC |
| Maximum module current | 37 mA, excluding sensor supply |
| Typical power loss | 0.85 W, excluding sensor supply |
| Input channels | 4 differential current inputs |
| Current ranges | 0–20 mA, 4–20 mA and −20 to +20 mA |
| Input resistance | 100 Ω; approximately 0.7 V additional diode drop in two-wire operation |
| Maximum input current destruction limit | 50 mA |
| Maximum resolution | 16 bits including sign and overrange |
| Interference suppression and conversion time | 16.6 / 50 / 60 Hz; 180 / 60 / 50 ms per channel |
| Smoothing | None, 4, 8 or 16 samples |
| Current measurement accuracy | Basic error ±0.3% at 25°C; operational error ±0.5% over temperature |
| Sensor supply | 24 V DC, short-circuit protected; 20 mA per channel, up to 50 mA for less than 10 s |
| Maximum two-wire transmitter burden | 650 Ω |
| Maximum shielded cable | 1000 m |
| Address space | 8 bytes; plus 1 byte for quality information |
| Wire-break diagnosis | Available in the 4–20 mA range |
| Common-mode voltage limit | 10 V DC between inputs |
| RUN parameter changes | Reparameterization supported; calibration in RUN not supported |
| Dimensions and approximate weight | 15 × 73 × 58 mm (W × H × D); 31 g |
Frequently Asked Questions
Can I connect a voltage-output transmitter directly to 6ES7134-6GD00-0BA1?
The module measures current signals and does not provide voltage-measurement channels.
Which BaseUnits can I use under 6ES7134-6GD00-0BA1?
Use a BaseUnit of type A0 or A1 with the CC03 channel identification.
When can 6ES7134-6GD00-0BA1 diagnose a broken signal wire?
Wire-break diagnosis is available for the four-to-twenty-milliampere measuring range.
What voltage drop should I include for a two-wire input circuit on 6ES7134-6GD00-0BA1?
Include the hundred-ohm input resistance and approximately seven-tenths of a volt of additional diode drop.
Can I change parameters on 6ES7134-6GD00-0BA1 while the station remains in RUN?
Reparameterization in RUN is supported, while calibration in RUN is not supported.
How does selecting sixty-hertz suppression affect conversion on 6ES7134-6GD00-0BA1?
The specified conversion time is fifty milliseconds per channel with sixty-hertz interference suppression.
How much input address space should I reserve for 6ES7134-6GD00-0BA1 with quality information?
Reserve eight bytes for measured values and one additional byte for quality information.