- Use the specified two-wire 4–20 mA transmitter arrangement and matching ET 200S terminal module.
- Check transmitter burden and shielded-cable length.
- Calculate response time from active channels, conversion setting and smoothing level.
- Account for the shared channel reference when planning the field wiring.
6ES7134-4GB01-0AB0 SIMATIC ET 200S 2AI Standard 4–20 mA Two-Wire Input Module
Two-channel Standard current input for 4–20 mA two-wire transmitters, with 13-bit resolution, configurable smoothing and an SF group-fault LED.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7134-4GB01-0AB0 |
| Product Type | Analog current input module |
| Core Function | Acquiring two-wire transmitter signals |
| Application | ET 200S distributed process I/O |
Two-wire current acquisition
Two analog channels measure 4–20 mA signals with a specified 13-bit resolution.
Configurable smoothing
Four filter levels use 1, 4, 32 or 64 module cycles for none, low, medium or high smoothing.
Process fault detection
Wire break, group fault and overflow/underflow diagnostics support fault location with a red SF indicator.
Product Overview
6ES7134-4GB01-0AB0 acquires two 4–20 mA transmitter signals in an ET 200S station, using an integrating conversion method and a compact 15 mm electronics-module width.
The cycle time depends on the number of active channels and the basic conversion setting, while configurable smoothing changes how quickly measured values follow process changes.
Key Functions
Two-wire current acquisition
Two analog channels measure 4–20 mA signals with a specified 13-bit resolution.
Configurable smoothing
Four filter levels use 1, 4, 32 or 64 module cycles for none, low, medium or high smoothing.
Process fault detection
Wire break, group fault and overflow/underflow diagnostics support fault location with a red SF indicator.
Official Specifications
| Analog channels and range | 2 inputs, 4–20 mA |
|---|---|
| Input resistance | 50 Ω |
| Rated load supply | 24 V DC from the power module |
| Maximum no-load L+ current | 80 mA |
| Maximum backplane current | 10 mA from 3.3 V DC |
| Typical power loss | 0.6 W |
| Address allocation | 4 bytes |
| Measurement method | Integrating |
| Resolution | 13 bits |
| Integration settings | 16.7 or 20 ms |
| Basic conversion time per channel | 55 or 65 ms |
| Module cycle calculation | Active-channel count multiplied by basic conversion time |
| Smoothing settings | None: 1 cycle; low: 4 cycles; medium: 32 cycles; high: 64 cycles |
| Maximum two-wire transmitter burden | 750 Ω |
| Maximum shielded cable length | 200 m |
| Current measurement error | ±0.6% over the full temperature range; ±0.4% basic error at 25 °C |
| Diagnostics | Wire break, group fault and overflow/underflow; red SF LED |
| Isolation | No inter-channel or load-supply isolation; isolated from backplane, tested at 500 V DC |
| Dimensions (W × H × D) | 15 × 81 × 52 mm |
| Approximate weight | 40 g |
Frequently Asked Questions
Can 6ES7134-4GB01-0AB0 be configured for a 0–20 mA measurement range?
The specified input range is 4–20 mA for two-wire transmitters.
Is 65 ms the complete cycle for two active channels on 6ES7134-4GB01-0AB0?
At a 65 ms basic conversion setting, two active channels give a 130 ms module cycle.
How much smoothing does the medium setting apply on 6ES7134-4GB01-0AB0?
The medium setting smooths the measured value over 32 module cycles.
What burden limit should be checked for a transmitter connected to 6ES7134-4GB01-0AB0?
The maximum specified two-wire transmitter burden is 750 Ω.
Are the two current channels of 6ES7134-4GB01-0AB0 isolated from each other?
The channels are not mutually isolated, although the input circuitry is isolated from the backplane bus.
What wiring distance is permitted for 6ES7134-4GB01-0AB0?
Use shielded signal wiring within the 200 m maximum.
Which process faults can 6ES7134-4GB01-0AB0 help identify?
The module detects wire breaks, group faults and measured-value overflow or underflow.