SIEMENS SIMATIC ET 200S

6ES7131-4BF50-0AA0 SIMATIC ET 200S 8 DI Source Input Module

An eight-channel 24 V DC source-input module with fixed input filtering and individual channel status indicators.

At a Glance

Brand Siemens
Model 6ES7131-4BF50-0AA0
Product Type Source-input digital module
Core Function Reading negative-switching sensor signals
Application ET 200S distributed I/O stations

Eight source inputs

The input thresholds use the source-input voltage convention relative to L+.

Fixed filtering

Both input transitions have a specified delay of 2–4.5 ms.

Compact station module

The module is 15 mm wide and receives its supply from the power module.

Product Overview

6ES7131-4BF50-0AA0 collects eight 24 V DC source-input signals in an ET 200S station. Its input characteristic follows IEC 61131 type 1 and the module supports isochronous operation.

The input delay is fixed, with no parameter setting for filtering. Green LEDs show the channel states, while the module provides neither a diagnostic function nor a red SF group-error indicator.

Ordering focus: Match the source-input polarity and L+ reference, the ET 200S station hardware and the two-wire sensor leakage-current limit.
Key Functions

Acquire source-input signals

Eight channels receive negative-switching sensor signals with the specified voltage thresholds.

Filter input transitions

A non-configurable 2–4.5 ms delay applies to rising and falling transitions.

Show local channel states

A green indicator is provided for each input channel.

Official Specifications
Digital inputs 8
Rated supply 24 V DC from the power module
Reverse-polarity protection Yes
Typical power loss 1.2 W
Input characteristic IEC 61131 type 1
Source-input voltage thresholds relative to L+ Signal 0: −5 to +30 V; signal 1: −30 to −15 V
Typical signal-1 current 6 mA at 24 V
Input delay, both transitions 2–4.5 ms; not parameterizable
Maximum cable length 1000 m shielded; 600 m unshielded
Two-wire sensor connection Supported; maximum quiescent current 1.5 mA
Diagnostics No diagnostic function or red SF group-error LED
Channel status indicators Green LED per input
Electrical separation Inputs separated from the backplane bus; no separation between channels
Insulation test voltage 500 V DC
Isochronous mode Supported
Dimensions 15 × 81 × 52 mm (W × H × D)
Approximate weight 35 g
Frequently Asked Questions

Which input voltage reference should I use for 6ES7131-4BF50-0AA0?

The source-input signal voltages are evaluated relative to L+.

Can I adjust the filtering time of 6ES7131-4BF50-0AA0?

The input delay is fixed at 2–4.5 ms for both transition directions.

What is the two-wire sensor limit for 6ES7131-4BF50-0AA0?

The maximum permissible sensor quiescent current is 1.5 mA.

Which cable-length limits apply to 6ES7131-4BF50-0AA0?

The maximum length is 1000 m for shielded cable and 600 m for unshielded cable.

Does 6ES7131-4BF50-0AA0 provide a red SF fault indicator?

It has green channel-status LEDs but no red SF LED or diagnostic function.

Are the input channels of 6ES7131-4BF50-0AA0 isolated from one another?

The channels share a potential group and are isolated from the backplane bus.

Where does 6ES7131-4BF50-0AA0 receive its 24 V supply?

The ET 200S power module provides the rated 24 V DC supply.

Compatibility & Ordering Notes
Before ordering 6ES7131-4BF50-0AA0: Retain the complete 4BF50 source-input order number and match the sensor polarity, terminal-module arrangement and station power module.

Compatibility Checklist for 6ES7131-4BF50-0AA0

  • Confirm source-input operation and the L+ signal-voltage reference.
  • Allow for the fixed 2–4.5 ms input delay.
  • Keep two-wire sensor quiescent current within 1.5 mA.
  • Apply the shielded or unshielded cable-length limit.
  • Use green channel LEDs for local state indication and account for the absence of module diagnostics.
Hot Selling Models
P1778B081002 0-100
9519/12-03
200PRO 6ES7194-4CA50-0AA0
300164 300164-40G
P530
RS232-PRO-PAC R911170440-GB1
6ES5304-3UB-11 6ES5491-0LB11
Z715.1K 071781
SACB10/3LM12M8
2n/o 773520
DI325
100S-C12DJ14C
TK858 6ES5858-0AA11
VAA-2E2A-KE1-S/E2
01141613

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.