SIEMENS SIMATIC ET 200S

6ES7131-4BF00-0AA0 SIMATIC ET 200S 8DI DC24V Input Module

An eight-channel 24 V DC input module in a 15 mm width, with a one-byte input address area and channel-status LEDs.

At a Glance

Brand Siemens
Model 6ES7131-4BF00-0AA0
Product Type Digital input module
Core Function Eight-channel sensor-state acquisition
Application ET 200S distributed I/O assemblies

Eight channels in 15 mm

The compact electronic unit acquires eight field-input states.

Fixed input filtering

Both signal edges use a typical 3 ms input delay.

External sensor distribution

The selected terminal base and supplementary terminals provide the necessary sensor-supply connections.

Product Overview

6ES7131-4BF00-0AA0 packs eight 24 V DC digital inputs into a single 15 mm ET 200S electronic module.

The input channels share a common potential and are isolated from the backplane bus, with green channel LEDs showing the acquired states and no module diagnostic function.

Ordering focus: Match the eight-channel module and terminal-base pattern, then provide enough separate potential terminals for the selected two-wire sensor arrangement.
Key Functions

Acquire eight discrete signals

The module reads switches or compatible two-wire proximity sensors through eight input channels.

Filter both input transitions

The fixed input delay is typically 3 ms for rising and falling transitions.

Map a compact process image

One byte holds the eight input states, and the module uses three parameter bytes.

Official Specifications
Input count 8 channels
Nominal supply and input voltage 24 V DC
ON-state input range 15–30 V
OFF-state input range −30 to +5 V
Typical input current at 24 V 5 mA per ON input
Input delay for both transitions Typically 3 ms; 2.0–4.5 ms range
Input characteristic IEC 61131 type 1
Two-wire sensor quiescent-current limit 1.5 mA
Maximum cable length 600 m unshielded; 1,000 m shielded
Process-image input area 1 byte
Parameter length 3 bytes
Typical power dissipation 1.2 W
Channel isolation No channel-to-channel isolation; isolated from the backplane bus
Permissible inter-circuit potential difference 75 V DC or 60 V AC
Isolation test voltage 500 V DC
Status indicators One green LED per input
Module diagnostics No diagnostic function
Isochronous operation Supported
Module width and weight 15 mm; approximately 35 g
Frequently Asked Questions

Does 6ES7131-4BF00-0AA0 provide a diagnostic alarm for a failed sensor wire?

No, this electronic module has no diagnostic function.

How much input address space does 6ES7131-4BF00-0AA0 occupy?

The eight channels occupy one byte of input address space.

Can I adjust 6ES7131-4BF00-0AA0 to a 0.1 ms input delay?

No, its input delay is fixed at typically 3 ms for both transitions.

Will an input at 12 V reliably count as ON on 6ES7131-4BF00-0AA0?

No, the specified ON-state range starts at 15 V.

How are channels 0 and 7 connected through the base for 6ES7131-4BF00-0AA0?

Channel 0 uses terminal 1 and channel 7 uses terminal 8 in the specified eight-input terminal assignment.

Do I need extra potential terminals for two-wire sensors connected through TM-E15S26-A1 with 6ES7131-4BF00-0AA0?

Yes, the illustrated two-wire arrangement uses additional terminals to provide enough 24 V sensor-supply connection points.

Are independent galvanically isolated sensor potentials available on each channel of 6ES7131-4BF00-0AA0?

No, the input channels are not isolated from one another.

Compatibility & Ordering Notes
Before ordering 6ES7131-4BF00-0AA0: Choose a supported eight-input terminal base, preserve the channel-to-terminal mapping and provide the sensor-supply distribution required by the field wiring.

Compatibility Checklist for 6ES7131-4BF00-0AA0

  • Use the 15–30 V ON-state threshold.
  • Observe the 1.5 mA sensor quiescent-current limit.
  • Provide additional potential terminals where needed.
  • Do not expect module diagnostic alarms.
Hot Selling Models
OFSL050P3ST3
ABB AF26Z-30-00-21
ABB 2CDS253001R0064 S203-C6
352-890
VL180-P460 6008785
MCR-V2-4012-70-250-5A-1
ABB S 202 C10
M22-DX M22-D-XQ
FAZNB25
Allen-Bradley 700-FEY2QU23
170ADI35000
3RV1321-4BC10
6ES7901-1BF00-0XA0
3RV1021-1FA10
AC-31

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.