Overview
SIEMENS SIMATIC ET 200B

6ES5700-2BD11 ET 200B TB2/DC Screw Terminal Block

A TB2/DC three-tier screw-terminal base for the 32-channel ET 200B wiring arrangement, with station coding and a replaceable sensor-supply fuse.

At a Glance

Brand Siemens
Model 6ES5700-2BD11
Product Type Digital station terminal block
Core Function Providing the fixed field-wiring interface
Application Removable ET 200B digital electronics

Three terminal tiers

Numbered connections run from 1 to 96 for the 32-channel arrangement.

Station setup

Coding and station-number settings remain on the terminal block.

Protected sensor supply

The TB2/DC uses a 2.5 A miniature fuse.

Product Overview

6ES5700-2BD11 provides the fixed TB2/DC wiring base for an ET 200B digital station. The three-tier screw-terminal arrangement accepts the removable electronics block while retaining the external field wiring.

The terminal block carries the station setup controls and the sensor-supply fuse. Before exchanging the electronics, set the base to STOP, preserve the terminal assignment and match the coding slide to the intended module class.

Ordering focus: Preserve the TB2/DC three-tier wiring, coding and station number when exchanging the electronics block.
Key Functions

Keep the field wiring in place

The electronics block plugs onto the terminal base so its field conductors can remain terminated.

Set the station identity

The terminal block provides the station-number setting and module-class coding.

Protect the local supply

A replaceable miniature fuse protects the sensor supply and internal logic supply against the stated fault conditions.

Official Specifications
Terminal structure 32-channel arrangement; 3 screw-terminal tiers
Numbered terminal allocation 1–32, 33–64 and 65–96
Station-number selector Two decimal digits, 00–99 setting range
Coding slide 6 mechanical settings
Sensor-supply fuse TR5-T 2.5 A, 250 V miniature fuse
Bare terminal-block dimensions 235 × 126.9 × 49.7 mm (W × H × D)
Installed protection IP20; protection class I
Operating temperature 0–60 °C in preferred horizontal installation; 0–40 °C in other positions
Storage and transport temperature −40 to +70 °C
Relative humidity 15–95 %, indoor, without condensation
Atmospheric pressure Operation: 795–1,080 hPa; storage/transport: 660–1,080 hPa
Vibration test 0.075 mm at 10 to <57 Hz; 1 g at 57 to <150 Hz
Shock test 15 g peak, 11 ms half-sine
Electrostatic discharge immunity 8 kV air discharge; 4 kV contact discharge
Frequently Asked Questions

Which station numbers can I use when operating 6ES5700-2BD11 with an IM 308-B master?

The permitted station-number range is 3 to 99 with that master interface.

Can I engage an electronics block on 6ES5700-2BD11 while the base remains in RUN?

Set the terminal-block STOP/RUN switch to STOP before engaging the electronics.

Which fuse should I fit to the sensor-supply circuit of 6ES5700-2BD11?

Use the specified TR5-T 2.5 A miniature fuse rated at 250 V.

How are the three numbered tiers on 6ES5700-2BD11 arranged?

The terminal tiers are numbered 1–32, 33–64 and 65–96.

Can 6ES5700-2BD11 be installed directly on a smooth mounting surface?

The ET 200B terminal block supports direct wall mounting as well as mounting on a standard sectional rail.

Which voltage range is allowed when using a different 24 V load supply with 6ES5700-2BD11?

The supply must remain between 20 and 30 V including ripple and provide safe electrical isolation.

How does the station containing 6ES5700-2BD11 connect to PROFIBUS DP?

The terminal-block bus interface uses a SINEC L2 bus connector.

Compatibility & Ordering Notes
Before ordering 6ES5700-2BD11: Keep the TB2/DC three-tier terminal assignment, 32-channel electronics arrangement, station coding and sensor-fuse rating.

Compatibility Checklist for 6ES5700-2BD11

  • Set the base to STOP before removing or engaging the electronics.
  • Use station numbers 3–99 with IM 308-B or 1–99 with IM 308-C and S7/M7 DP masters.
  • Preserve the protective-ground and equipotential connections.
  • Fit the specified TR5-T 2.5 A fuse after correcting the fault.
Hot Selling Models
1942910
PA-1NK 2UZ
ME-01 CS ME-01V024
252.06Z 3002.5206Z
XACA201
3RT1034-3BB40
1507638
KSK-1999CP1500 0541383 0547755
HEE-1/4-D-MINI-24
IFO218010ZPKG
RDFA-LCN
ABB CDPI-01/-02 ACS580/ACH580
51453568-006
AP001 C500-AP001 3G2A5-AP001
P363/EA/SVBSW

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.