siemens 6av3688 3eh47 0ax0 simatic hmi kp32f pn key panel-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC HMI KP32F PN Key Panel 6AV3688-3EH47-0AX0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIMATIC HMI

6AV3688-3EH47-0AX0 SIMATIC HMI KP32F PN Key Panel

The KP32F PN combines thirty-two short-stroke keys, multicolor LEDs, PROFINET with PROFIsafe and configurable standard or safety-related I/O.

At a Glance

Brand Siemens
Model 6AV3688-3EH47-0AX0
Product Type PROFINET PROFIsafe key panel
Core Function Combines illuminated operator keys with standard and fail-safe field signals
Application or Compatible Series Machine panels requiring PROFINET and PROFIsafe operator inputs

Exact Identification

Match 6AV3688-3EH47-0AX0 character by character and confirm the complete SIMATIC HMI KP32F PN Key Panel designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The KP32F PN combines thirty-two short-stroke keys, multicolor LEDs, PROFINET with PROFIsafe and configurable standard or safety-related I/O.

Thirty-two illuminated keys provide clear local commands and feedback. Four dedicated fail-safe inputs communicate through PROFIsafe. Standard inputs and configurable digital I/O reduce separate control-panel hardware.

Ordering focus: match the PN/PROFIsafe variant, STEP 7 project, safety address, I/O assignment, cutout and 24 V DC wiring.
Key Functions

Direct Machine Operation

Thirty-two illuminated keys provide clear local commands and feedback.

Safety-Capable Inputs

Four dedicated fail-safe inputs communicate through PROFIsafe.

Flexible Field Wiring

Standard inputs and configurable digital I/O reduce separate control-panel hardware.

Official Specifications
Short-Stroke Keys 32
Function Keys 32
LED Color Modes Red, green, blue, yellow and white
Direct Process LEDs 8
Standard Digital Inputs 16
Configurable Digital I/O 16 DI/DO
Fail-Safe Inputs 4
Communication Network PROFINET
Safety Communication PROFIsafe
PROFINET Ports 2
Rated Supply 24 V DC with loop-through
Engineering Baseline STEP 7 V5.5 or later
Maximum Output Current per Channel 100 mA
Maximum Output Current per Group 800 mA
Front Protection IP65
Rear Protection IP20
Frequently Asked Questions

How many physical operator keys are available on 6AV3688-3EH47-0AX0?

The front panel provides thirty-two parameterizable short-stroke keys.

Can 6AV3688-3EH47-0AX0 exchange fail-safe signals over PROFINET?

Yes; four fail-safe inputs are integrated through PROFIsafe communication.

How much standard field I/O does 6AV3688-3EH47-0AX0 provide?

It has sixteen digital inputs plus sixteen channels that can be configured as inputs or outputs.

Which engineering software baseline is required for 6AV3688-3EH47-0AX0?

Use STEP 7 V5.5 or a later compatible release.

Can the 24 V supply be looped through 6AV3688-3EH47-0AX0?

Yes; the rated supply arrangement supports 24 V DC loop-through wiring.

What enclosure rating applies to 6AV3688-3EH47-0AX0 after panel mounting?

The installed front is rated IP65 and the rear is rated IP20.

What must be validated after replacing 6AV3688-3EH47-0AX0?

Test every key, LED, standard channel, fail-safe input, PROFINET name and PROFIsafe address.

Compatibility & Ordering Notes
Before ordering 6AV3688-3EH47-0AX0: match the PN/PROFIsafe variant, STEP 7 project, safety address, I/O assignment, cutout and 24 V DC wiring.

Compatibility Checklist

  • Use the panel in a PROFINET configuration that includes the matching PROFIsafe parameters.
  • Keep the device name, IP settings, safety address and key assignment aligned with the approved project.
  • Perform the required safety-function validation after any replacement.
Hot Selling Models
1739245000
3RV1421-1KA10
6SL3262-1AA00-0BA0
VMPA2-RP
5TE8413
Allen-Bradley 140M-C-W452N
SACC-MINFS-5CON-PG13/2.5
7000-88001-0300060
SMM-8
3TH4022-0A
SAC-5P-MINMS/0.3-441/MINFS
Ti2-SU1Z
ABB S203-C10
2-2MBD 2819066
18M-PA-1PD-E5-C-S4