Overview
Place of Origin: |
Sweden |
Brand Name: |
ABB |
Model Number: |
PP836A 3BSE042237R2 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Model |
PM891K01 3BSE053241R1 |
|
Product Type |
Processor Unit |
|
Dimensions |
20 x 18.7 x 10 cm |
|
Weight |
1.64 kg |
|
Redundancy |
No |
|
High Integrity |
No |
|
Clock Frequency |
450 MHz |
|
Performance (1000 boolean operations) |
0.043 ms |
|
Performance |
0.043 ms |
|
Memory |
256 MB |
|
RAM available for application |
208.985 MB |
|
Flash memory for storage |
Yes |
|
Processor type |
MPC8270 |
|
Switch over time (redundant configuration) |
Max 10 ms |
|
Applications per controller |
32 |
|
Programs per application |
64 |
|
Diagrams per application |
128 |
|
Tasks per controller |
32 |
|
Number of cycle times |
32 |
|
Cycle time per application program |
Down to 1 ms |
|
Firmware storage (Flash PROM) |
16 MB |
|
Power supply |
24 V DC (19.2–30 V DC) |
|
Power consumption (typ/max) |
660 / 750 mA |
|
Power dissipation |
15.8 W (18 W max) |
|
Redundant power supply status input |
Yes |
|
Built-in backup battery |
No |
|
Clock synchronization |
1 ms (CNCP protocol between AC 800M controllers) |
|
Event queue per OPC client |
Up to 3000 events |
|
Transmission speed to OPC server |
36–86 events/sec, 113–143 data messages/sec |
|
CEX bus communication modules |
12 |
|
CEX bus supply current |
Max 2.4 A |
|
I/O clusters (non-redundant CPU) |
0 electrical + 7 optical |
|
I/O clusters (redundant CPU) |
0 electrical + 7 optical |
|
I/O capacity (Modulebus) |
Max 84 modules |
|
Modulebus scan rate |
0–100 ms |
|
Electrical Modulebus supply current (24 V) |
Max 1.0 A |
|
Electrical Modulebus supply current (5 V) |
Max 1.5 A |
|
Ethernet channels |
2 |
|
Ethernet interface |
10/100 Mbit/s |
|
Control Network protocol |
MMS / IAC |
|
Recommended Control Network backbone |
100 Mbit/s switched Ethernet |
|
Real-time clock stability |
50 ppm (~0.5 h/year) |
|
RS-232C interfaces |
1 (COM4 service tool) |
|
COM3 (RS-232C) |
Not supported |
|
COM4 (RS-232C) |
9600 baud, RJ-45, opto-isolated, no RTS-CTS |
Description
The PM891K01 3BSE053241R1 processor is a monolithic unit equipped with power supply, CPU-boards and unit termination. The unit contains microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button and a Secure Digital interface. The PM891 does not contain any internal battery The PM891 has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and one RJ45 serial port (COM4). The COM4 port is isolated and used for a configuration tool. The PM891K01 3BSE053241R1 supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O).
Environment and certification
|
Parameter |
Value |
|
Operating Temperature |
0 to +55 °C (+32 to +131 °F) |
|
Storage Temperature |
-40 to +70 °C (-40 to +158 °F) |
|
Temperature Change Rate |
3 °C/min (IEC/EN 61131-2) |
|
Pollution Degree |
Degree 2 (IEC/EN 61131-2) |
|
Corrosion Protection |
G3 (ISA 71.04 compliant) |
|
Relative Humidity |
5 to 95%, non-condensing |
|
Emitted Noise |
Not specified |
|
Vibration (10–50 Hz) |
0.0375 mm amplitude |
|
Vibration (50–150 Hz) |
0.5 g acceleration |
|
Vibration (5–500 Hz) |
0.2 g acceleration |
|
Rated Isolation Voltage |
50 V |
|
Dielectric Test Voltage |
500 V AC |
|
Protection Class |
IP20 (EN 60529, IEC 529) |
|
Altitude Rating |
Up to 2000 m (IEC/EN 61131-2) |
|
EMC Emission & Immunity |
EN 61000-6-4 / EN 61000-6-2 |
|
Environmental Conditions |
Industrial |
|
CE Mark |
Yes |
|
Electrical Safety Standards |
EN 50178, IEC 61131-2, UL 61010-1, UL 61010-2-201 |
|
Hazardous Location Approval |
UL 60079-15; cULus Class 1, Zone 2; AEx nA IIC T4; Ex nA IIC T4 Gc X |
|
Marine Certifications |
ABS, BV, DNV-GL, LR |
|
TÜV Approval |
No |
|
RoHS Compliance |
EU RoHS, UAE RoHS, CN RoHS |
|
WEEE Compliance |
Directive 2012/19/EU |
Applications
Large-scale petrochemical plants: Used to control extremely complex, plant-wide interlocking systems with massive data volumes.
Supercritical/ultra-high voltage power plants: Serving as the core DCS controller, managing massive amounts of real-time analog signals and control loops.
Large offshore drilling platforms: Used in space-constrained environments with extremely high requirements for integration and processing speed.
Modern pulp and paper mills: Handling the coordinated control of ultra-large-scale fully automated papermaking lines.
Large-scale data center power stations: Managing highly intensive power monitoring and cooling linkage systems.
Features and benefits
Reliability and simple fault diagnosis procedures
Modularity, allowing for step-by-step expansion
IP20 Class protection without the requirement for enclosures
The controller has full EMC certification
High performance and large application memory
Sectioned CEX-Bus using a pair of BC810
Built-in redundant Ethernet Communication ports
FAQ
Q: Can the PM891K01 3BSE053241R1 be directly plugged into an older TP830 baseboard?
A: No. The PM891 requires a dedicated TP891 baseboard with different pin definitions and physical dimensions.
Q: What is the biggest advantage of the PM891K01 3BSE053241R1?
A: Its core advantages are its massive 256MB of memory and battery-free program and data backup, unique in the AC 800M series.
Q: How many I/O signals does the PM891K01 3BSE053241R1 support?
A: Due to its large memory, it can easily support over 5000 I/O points, with the specific upper limit depending on the communication scan cycle requirements.
Q: Can the status lights and information on the screen of the PM891K01 3BSE053241R1 be customized?
A: The screen mainly displays preset system diagnostic information (such as IP address, firmware version, and operating status), and cannot be customized like an HMI.
Q: What precautions should be taken when replacing the PM891K01 3BSE053241R1?
A: Ensure that the firmware of the new module is compatible with the existing software engineering of the control station, as the PM891 typically requires a higher version of the ABB system environment.