Omron S8VS-03024/ED2 S8VS 30W DIN Rail Power Supply
Manufacturer: Omron
Condition: Brand New
Lead Time: In Stock
Origin: China
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Keep the connected load within the 1.3 A output rating and apply temperature derating.
- Use the correct input terminals and avoid inverter-output input power.
- Allow for the cold-start inrush current when selecting the upstream supply arrangement.
- Do not use parallel load sharing; use the required diode arrangement if connecting two supplies in series.
S8VS-03024/ED2 S8VS 30W DIN Rail Power Supply
A compact 24 V DC supply with a 1.3 A output, screw terminals and status indication.
At a Glance
| Brand | Omron |
|---|---|
| Model | S8VS-03024/ED2 |
| Product Type | Switch-mode power supply |
| Core Function | Convert input power for control loads |
| Application | DIN rail control-panel power distribution |
Control power
A 30 W class output supplies 24 V DC control loads.
Compact mounting
The covered supply mounts on a DIN rail with screw-terminal wiring.
Visible status
Green output and red undervoltage indicators support local checks.
Product Overview
S8VS-03024/ED2 provides a 24 V DC, 1.3 A output from a nominal 100 to 240 V AC supply.
The S8VS unit combines adjustable output voltage, overload protection and overvoltage protection in a compact DIN rail housing. The full /ED2 identifier is retained as the product version.
Key Functions
Supply a regulated DC rail
The output can be adjusted from −10% to +15% of its nominal voltage to suit the connected load.
Indicate supply condition
The green output indicator and red undervoltage indicator provide local status information.
Protect the output circuit
Overload protection resets automatically, while an overvoltage trip requires an input-power reset.
Official Specifications
| Rated Output | 24 V DC, 1.3 A |
|---|---|
| Power Class | 30 W |
| Nominal AC Input | 100 to 240 V AC |
| Allowable Input Range | 85 to 264 V AC or 80 to 370 V DC |
| Input Frequency | 50/60 Hz nominal; 47 to 450 Hz allowable |
| Typical Efficiency | 85% at 100 V AC; 86% at 200 V AC |
| Maximum AC Input Current | 0.9 A at 100 V AC; 0.6 A at 200 V AC |
| Maximum Inrush Current | 17.5 A at 100 V AC; 35 A at 200 V AC, cold start at 25°C |
| Output Voltage Adjustment | −10% to +15% of rated output voltage |
| Maximum Ripple | 150 mV peak-to-peak at rated input and output |
| Static Input Variation | 0.5% maximum at full load |
| Static Load Variation | 1.5% maximum over 0 to 100% load at rated input |
| Maximum Temperature Variation | 0.05% per °C |
| Overload Response | Automatic recovery |
| Overvoltage Reset | Input power off for at least 3 minutes, then on |
| Operating Temperature | −10 to +60°C with applicable load derating |
| Operating Humidity | 25 to 85% RH, without condensation or icing |
| Mounting and Terminals | DIN rail mounting; screw terminals with terminal-block cover |
| Dimensions (W × H × D) | 22.5 × 85 × 96.4 mm |
| Maximum Weight | 180 g |
Frequently Asked Questions
Can I use S8VS-03024/ED2 on a 230 V AC control-panel supply?
Yes, 230 V AC is within its nominal input range of 100 to 240 V AC.
How far can I adjust the output of S8VS-03024/ED2?
The output voltage adjuster provides a −10% to +15% adjustment range around the rated 24 V output.
Can I parallel two units of S8VS-03024/ED2 for load sharing?
No, parallel load-sharing operation is not supported.
Can two units of S8VS-03024/ED2 be connected in series?
Yes, up to two units can be connected in series using the required external diode arrangement.
How do I reset an overvoltage trip on S8VS-03024/ED2?
Turn the input power off for at least three minutes and then turn it back on.
Can I power S8VS-03024/ED2 from an inverter output?
No, an inverter output must not be used as the input source for this supply.
What should I allow for when using S8VS-03024/ED2 in a hot enclosure?
Keep the ambient temperature within −10 to +60°C and apply the load derating required for the mounting and operating conditions.