Overview
Place of Origin: |
USA |
Brand Name: |
Bently Nevada |
Model Number: |
3500/45 176449-04 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Quick Detail
|
Rack Space Requirements |
1 full-height rear slot |
|
Operating Temperature |
-30°C to +65°C (-22°F to +150°F) |
|
Storage Temperature |
-40°C to +85°C (-40°F to +185°F) |
|
Humidity |
95% Non-condensing |
|
Signal |
Accepts from 1 to 4 signal inputs |
|
Power consumption |
7.7 Watts, typical, using Position I/O |
|
Input Impedance |
1 MΩ (DC LVDT inputs) 10 kΩ (Proximitor or RPT inputs) 137 kΩ (AC LVDT inputs) 200 kΩ (Rotary Potentiometer inputs) |
|
Thrust Sensitivity |
3.94 mV/μm (100 mV/mil) or 7.87 mV/μm (200 mV/mil) |
|
Dimension: |
25.5x2.8x24.2cm |
|
Weight: |
0.84kg |
Description
The 3500/45 176449-04 Position Monitor is a 4-channel instrument designed for industrial automation, accepting inputs from proximity transducers, Rotary Position Transducers, DC and AC LVDTs, and rotary potentiometers. Each channel conditions signals with impedances of 10 kΩ for Proximitor/RPT, 1 MΩ for DC LVDT, 137 kΩ for AC LVDT, and 200 kΩ for potentiometers, providing thrust sensitivity of 3.94–7.87 mV/µm and differential expansion sensitivity of 0.394–0.787 mV/µm. The 3500/45 176449-04 Position Monitor uses 3500 Rack Configuration Software to program axial position, dual ramp, case expansion, valve, and differential expansion monitoring. Alarm setpoints are adjustable from 0–100% full-scale with ±0.33% typical accuracy. Consuming 7.7 W per channel and operating from -30°C to +65°C, the 3500/45 176449-04 Position Monitor delivers real-time measurements for automation control and predictive maintenance.
Applications
The 3500/45 176449-04 Position Monitor tracks turbine axial and thrust positions using Proximitor inputs at 10 kΩ impedance, generating thrust measurements with 3.94–7.87 mV/µm sensitivity. Alerts are triggered when values exceed programmed thresholds.
Measure Differential Expansion in Heat Exchangers
The 3500/45 176449-04 Position Monitor conditions DC LVDT signals at 1 MΩ, producing differential expansion data with 0.394–0.787 mV/µm sensitivity. Alarm setpoints from 0 to 100% full-scale notify operators of mechanical movement.
Control Valve Positions in Process Systems
The 3500/45 176449-04 Position Monitor measures rotary potentiometer signals at 200 kΩ, delivering valve position readings with ±0.33% full-scale accuracy for automated valve control.
Compare Dual Ramp Expansions in Compressors
Using AC LVDT inputs at 137 kΩ, the 3500/45 176449-04 Position Monitor records dual ramp expansions with 0.394–7.874 V/mm sensitivity, supporting predictive maintenance and operational adjustments.
Record Case Expansion in Large Motors
The 3500/45 176449-04 Position Monitor monitors case expansion signals, providing real-time measurements at 7.7 W per channel while operating from -30°C to +65°C, enabling
Specifications
|
Differential Expansion Sensitivity |
0.394 mV/μm (10 mV/mil) or 0.787 mV/μm (20 mV/mil) |
|
Ramp Differential Expansion Sensitivity |
0.394 V/mm (10 mV/mil), 0.787 V/mm (20 mV/mil), 3.937 V/mm (100 mV/mil), or 7.874 V/mm (200 mV/mil) |
|
Thrust and Differential Expansio(Accuracy) |
Within ±0.33% of full-scale typical ±1% maximum |
|
Thrust and Differential Expansio(Direct filter Frequency Response) |
-3 dB at 1.2 Hz |
|
Thrust and Differential Expansio(Gap filter Frequency Response) |
-3 dB at 0.41 Hz |
|
Alarm Setpoints |
Use the 3500 Rack Configuration Software to set alert and danger levels for the direct values measured by the monitor. Alarms are adjustable from 0 to 100% of full-scale for each measured value. However, when the full-scale range exceeds the range of the transducer, the range of the transducer will limit the setpoint. |
|
Accuracy of alarm setpoints |
Within 0.13% of the desired value |
|
|
|
|
Valve Position Accuracy |
Within ±0.33% of full-scale typical ±1% maximum |
|
Valve Position(Direct filter Frequency Response) |
-3 dB at 1.2 Hz |
|
Valve Position(Gap filter Frequency Response) |
-3 dB at 0.41 Hz |
Competitive Advantage
Support Multiple Signal Types in One Monitor
The 3500/45 176449-04 Position Monitor integrates Proximitor, RPT, DC and AC LVDTs, and rotary potentiometers into a single 4-channel device, reducing rack space and wiring complexity.
Deliver Accurate Alarm Measurements
With thrust sensitivity of 3.94–7.87 mV/µm and differential expansion sensitivity of 0.394–0.787 mV/µm, the 3500/45 176449-04 Position Monitor triggers alarms within ±0.33% typical full-scale, providing precise measurement for automation control.
Program Measured Variable Alarms
The 3500/45 176449-04 Position Monitor allows alert and danger setpoints from 0 to 100% full-scale for each measured variable, enabling fine-tuned operational thresholds.
Maintain Real-Time Frequency Response
The 3500/45 176449-04 Position Monitor achieves direct filter response of -3 dB at 1.2 Hz and gap filter response of -3 dB at 0.41 Hz, supporting continuous measurement for automated systems.