Conspectus
Locus originis: |
USA |
Nomen marcae: |
Bently Nevada |
Numerus exemplaris: |
3500/45 176449-04 |
Particularia impaquetandi: |
Originales nova Officina Sigillata |
Tempus solutionis: |
5-7 dies |
Conditiones solutionis: |
T/T |
Vis Supplicandi: |
In stirpe |
Velox Detail
|
Requisita Spatii in Reticulo |
1 interstitium posterius plene altum |
|
Temperatura operativa |
−30°C ad +65°C (−22°F ad +150°F) |
|
Temperatura recondita |
-40°C ad +85°C (-40°F ad +185°F) |
|
Humiditas |
95% non condensans |
|
Signum |
Accipit ab uno ad quattuor signorum introitus |
|
Consumptio potentiae |
7,7 Vattus, ut solet, utendo Positione I/O |
|
Input impedimentum |
1 MΩ (introitus DC LVDT) 10 kΩ (introitus Proximitor vel RPT) 137 kΩ (introitus AC LVDT) 200 kΩ (introitus Potentiometri Rotatorii) |
|
Sensibilitas ad Impulsum |
3.94 mV/μm (100 mV/mil) aut 7.87 mV/μm (200 mV/mil) |
|
Dimensiones: |
25,5 × 2,8 × 24,2 cm |
|
Pondus: |
0.84kg |
Descriptio
The monitor positionis 3500/45 176449-04 instrumentum est quattuor canalium ad automationem industrialem destinatum, quod signa accipit e transductoribus proximitatis, transductoribus positionis rotativis, LVDT directae et alternatae correntis, et potentiometris rotativis. Singuli canales signa condicionant impedantiis 10 kΩ pro Proximitor/RPT, 1 MΩ pro LVDT directae correntis, 137 kΩ pro LVDT alternatae correntis, et 200 kΩ pro potentiometris, praebens sensibilitatem pro impulsum 3,94–7,87 mV/µm et sensibilitatem pro expansione differentiale 0,394–0,787 mV/µm. monitor positionis 3500/45 176449-04 utitur 3500 Rack Configuration Software ad programmationem positionis axialis, duplicis rampae, expansionis carceris, valvulae et expansionis differentialis. Puncta allarum regolabilia sunt ab 0 usque ad 100% scalae plenae, cum typica accuratia ±0,33%. Consumit 7,7 W per canallem et operatur a −30°C usque ad +65°C, monitor positionis 3500/45 176449-04 praebet mensuras in tempore reali ad automationis regulam et maintenance praedictivam.
Usus
The monitor positionis 3500/45 176449-04 sequitur positiones axiales et thrust turbinum per signales Proximitor ad impedantiam 10 kΩ, generans mensuras thrust cum sensibilitate 3,94–7,87 mV/µm. Alarma excitantur ubi valores superant limina programmanda.
Mensura Expansionis Differentialis in Scambiatoribus Caloris
The monitor positionis 3500/45 176449-04 condicionat signales DC LVDT ad 1 MΩ, producens data expansionis differentialis cum sensibilitate 0,394–0,787 mV/µm. Puncta allarum ab 0 usque ad 100% scalae plenae operatoribus nuntiant motum mechanicum.
Regulat Positiones Valvularum in Systematibus Processualibus
The monitor positionis 3500/45 176449-04 mensurat signa potentiometri rotatorii ad 200 kΩ, praebens lectiones positionis valvulae cum accuratia ±0.33% in scala plena pro automatico regimine valvularum.
Comparare Expansiones Rampae Duplex in Compressoribus
Usans inpulsus AC LVDT ad 137 kΩ, monitor positionis 3500/45 176449-04 registrat expansiones rampae duplex cum sensibilitate 0.394–7.874 V/mm, sublevans manutenationem praedictivam et adaptationes operationales.
Registra Expansionem Carchassis in Motoribus Magnis
The monitor positionis 3500/45 176449-04 monitorat signa expansionis carchassii, praebens mensuras in tempore reali ad 7.7 W per canallem dum operatur a −30°C ad +65°C, permittens
Specificationes
|
Sensibilitas Incrementi Differentialis |
0,394 mV/μm (10 mV/mil) aut 0,787 mV/μm (20 mV/mil) |
|
Sensibilitas Incrementi Differentialis Gradualis |
0,394 V/mm (10 mV/mil), 0,787 V/mm (20 mV/mil), 3,937 V/mm (100 mV/mil), aut 7,874 V/mm (200 mV/mil) |
|
Impulsus et Incrementum Differentiale (Accuratio ) |
Intra ±0,33% valoris pleni, typice ±1% maximum |
|
Impulsus et Incrementum Differentiale (Responsio in Frequentia Filtrationis Directae ) |
−3 dB ad 1,2 Hz |
|
Impulsus et Incrementum Differentiale (Responsio frequentialis filtrī interstitiālis ) |
−3 dB ad 0,41 Hz |
|
Puncta constitūta allārmis |
Utere ōrnāmentō 3500 Rack Configuration Software ad constituenda puncta monitūs et perīculī pro valoribus directē mēnsūrātīs ā monitorē. Allārmae sunt adiūstābiles ab 0 usque ad 100 % plēnī scālae pro quōlibet valōre mēnsūrātō. Tamen, cum scāla plēna excedit ambitum trānsductōris, ambitus trānsductōris limitābit punctum constitūtum. |
|
Accuratio punctorum allarum |
Intra 0,13% valoris desiderati |
|
|
|
|
Accūrātia positīōnis vālvulae |
Intra ±0,33% valoris pleni, typice ±1% maximum |
|
Positīō vālvulae (responsiō frequentialis filtrī directī) |
−3 dB ad 1,2 Hz |
|
Positīō vālvulae (responsiō frequentialis filtrī interstitiālis) |
−3 dB ad 0,41 Hz |
Aliquam commodo
Sublevare Plures Species Signorum in Uno Monitori
The monitor positionis 3500/45 176449-04 integrat Proximitores, RPT, LVDT directae currentis et alternantis, et potentiometros rotatorios in unum instrumentum quattuor canalium, minuens spatium in armario et complexitatem conexorum.
Praebere Accuratas Lectiones Alarum
Cum sensibilitate pro impulsum 3,94–7,87 mV/µm et sensibilitate pro expansione differentiale 0,394–0,787 mV/µm, monitor positionis 3500/45 176449-04 excitat alarmas intra ±0,33 % typicum pleni scalae, praebens praecisam mensuram pro automatis controlibus.
Programma Alarum Variabilis Mensuratae
The monitor positionis 3500/45 176449-04 permittit puncta allertae et periculi a 0 ad 100 % pleni scalae pro singula variabili mensurata, faciens subtiliter definitos limites operationales.
Servare Responsionem Frequentialis in Tempore Reali
The monitor positionis 3500/45 176449-04 attingit directam responsionem filtrantis −3 dB ad 1,2 Hz et responsionem filtrantis interstitii −3 dB ad 0,41 Hz, sustinens continuam mensuram pro systematibus automatizatis.