Siemens SIMATIC NET DP/AS-Interface Link 20E Gateway 6GK1415-2AA10
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origin: Czech Republic
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens • SIMATIC NET DP/AS-Interface Link 20E
6GK1415-2AA10 SIMATIC NET DP/AS-Interface Link 20E Gateway
SIMATIC NET DP/AS-Interface Link 20E a Siemens connectit controllorem PROFIBUS DP ad unam rete AS-Interface et sustinet specificatonem AS-Interface V3.0 cum functione magistri M4.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6GK1415-2AA10 |
| Typus Producti | PROFIBUS DP-to-AS-Interface gateway |
| Functio principalis | Links PROFIBUS DP controllers with AS-Interface field devices |
| Applicatio vel series compatibiles | PROFIBUS DP automation systems using an AS-Interface field network |
Identificatio exacta.
Match 6GK1415-2AA10 character by character and confirm the complete SIMATIC NET DP/AS-Interface Link 20E Gateway designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
SIMATIC NET DP/AS-Interface Link 20E a Siemens connectit controllorem PROFIBUS DP ad unam rete AS-Interface et sustinet specificatonem AS-Interface V3.0 cum functione magistri M4.
The gateway transfers digital process data between PROFIBUS DP and one AS-Interface line. Commissioning can use the device SET button, STEP 7, a GSD file or the command interface. The documented redundancy capability allows operation in a suitable Y-Link arrangement.
Key Functions
Fieldbus Gateway
The gateway transfers digital process data between PROFIBUS DP and one AS-Interface line.
Local and Project Configuration
Commissioning can use the device SET button, STEP 7, a GSD file or the command interface.
Redundant System Option
The documented redundancy capability allows operation in a suitable Y-Link arrangement.
Official Specifications
| Gradus praesidium | IP20 |
|---|---|
| AS-Interface Connection | Screw-type connection |
| Mēthodus Alimentī | Per AS-Interface |
| Maximum AS-Interface Current at 30 V | 200 MA |
| Ammissio Potentiae | 4.5 W |
| Tensionis insulatio evaluata | 500 V |
| Isolatio galvanica | Supportata |
| Indicatores Status | PWR, APF, CER, AUP, CM, BF and SF LEDs |
| Configuration Methods | SET button, STEP 7, GSD or command interface |
| AS-Interface Specification | Versio 3.0 |
| AS-Interface Magister Profilus | M4 |
| Interfacies physicae | Unus AS-Interface et unus RS485 interfacius |
| Maximi AS-Interface Intritus | 496 |
| Maximi AS-Interface Extritus | 496 |
| Maximi AS-Interface Servi | 62 |
| AS-Interface Bus Cyclum | 5 ms pro 31 servis; 10 ms pro 62 servis |
| Dimensiones custodis | 90 x 80 x 62 mm |
| Modus montandi | Adfixio per adhaesionem in 35 mm DIN-rail |
| Temperatura operativa | 0 ad 60 °C horizontaliter; 0 ad 45 °C verticaliter |
| Altitudo Installationis Maxima | 2,000 m |
Quaestiones Frequenter Rogatae
Quot servos AS-Interface 6GK1415-2AA10 administrare potest?
Una linea usque ad 62 servos AS-Interface continere potest.
Quam connexionem PROFIBUS 6GK1415-2AA10 utitur?
Conexio campi bus RS485 interfaciem ad communicationem PROFIBUS DP utitur.
Num 6GK1415-2AA10 sine STEP 7 committari potest?
Ita; pulsator localis SET aut configuratio basata in GSD uti potest, ubi projectum permittit.
Quam celeriter 6GK1415-2AA10 lineam AS-Interface integram scannat?
Cyclus est 5 ms cum 31 servis et 10 ms cum 62 servis.
Can 6GK1415-2AA10 be installed in a redundant PROFIBUS system?
Yes; redundancy is supported in the documented Y-Link arrangement.
What should be recorded before replacing 6GK1415-2AA10?
Preserve the PROFIBUS address, AS-Interface configuration, slave assignments and controller project.
Which mounting rail is suitable for 6GK1415-2AA10?
The enclosure snaps onto a standard 35 mm DIN rail.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use an AS-Interface installation that complies with specification V3.0 and the M4 master profile.
- Restore the PROFIBUS and AS-Interface addresses exactly from the validated project.
- Check the mounting orientation because the permitted operating temperature differs between horizontal and vertical installation.