Siemens SIDOOR ATD420W Controller Ostii 6FB1141-2AT10-3WE2
Fabricator: Siemens
Status: Novissimum
Tempus Expectatus: In Stoc
Origo: Germania
Praestatio: 12 menses
Email: [email protected]
whatsapp: +86-18150117685
- Praevisio
- Productum Overview
- Functiones Principales
- Official Specifications
- FREQUENTLY ASKED QUESTIONS
- Compatibility & Ordering Notes
- Hot Selling Models
- Pròdòt ràccumandà
Praevisio
SIEMENS • SIDOOR ATD4xxW
6FB1141-2AT10-3WE2 SIDOOR ATD420W Door Controller
The SIDOOR ATD420W is an industrial door control unit with PROFIBUS DP-V0 communication, isolated digital control inputs, and interfaces for machine-door safety sensors and protective devices.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6FB1141-2AT10-3WE2 |
| Product Type | Industrial door control unit with PROFIBUS |
| Functio principalis | Controls industrial machine doors and exchanges cyclic data over PROFIBUS DP |
| Applicatio vel series compatibiles | SIDOOR industrial door drives with DCOPS sensors and protective devices |
Identificatio exacta.
Match 6FB1141-2AT10-3WE2 character by character and confirm the complete SIDOOR ATD420W Door Controller designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Productum Overview
The SIDOOR ATD420W is an industrial door control unit with PROFIBUS DP-V0 communication, isolated digital control inputs, and interfaces for machine-door safety sensors and protective devices.
Controlor operat ut DP-V0 servus et intercambit datos cyclicos cum magistro PROFIBUS classis 1 per interfaciem RS-485 basatam in SPC3. AssistedDrive et ImpulseDrive sustinent motum manualem auxiliatum a motore et motum automaticum excitatum ab impulso levi fortitudinis. Systema sustinet sensura DCOPS, barrierae lucis simplices, margines tutelares et cortinas lucis conformes ad IEC 61496.
Functiones Principales
Integratio Ostii PROFIBUS
Controlor operat ut DP-V0 servus et intercambit datos cyclicos cum magistro PROFIBUS classis 1 per interfaciem RS-485 basatam in SPC3.
Functiones Ostiorum Industrialium
AssistedDrive et ImpulseDrive sustinent motum manualem auxiliatum a motore et motum automaticum excitatum ab impulso levi fortitudinis.
Conectivitas Dispositivorum Tutelarium
Systema sustinet sensura DCOPS, barrierae lucis simplices, margines tutelares et cortinas lucis conformes ad IEC 61496.
Official Specifications
| Potentia Activa in Statu Standby | 5 w |
|---|---|
| Ingressus Controlis Digitalis | Isolatus et commutatio p |
| Tensio Ingressus Permissa | 10 ad 28 V CC; observa polaritatem |
| Currens Ingressus Signum 1 | 9 ad 27 mA |
| Valor Contactus Relais ad 30 V CC | 0,01 A minimum ad 1 A maximum |
| Latitudo Aperitionis Foris | 0,3 ad 5 m |
| Pondus Maximum Ostii | 600 KG |
| Cycli Operationis Maximi | 180 per horam |
| Contravis Maxima | 75 N |
| Energia Cinetica Maxima | 100 J |
| Interfacs bus campi | PROFIBUS secundum IEC 61784-3 |
| Rôlus Protocoli PROFIBUS | Servus DP-V0 cum communicatione magistri cyclicae classis 1 |
| Nodi Bus Maximi | 32 |
| Stratum Physicum Bus | RS-485 secundum ANSI TIA/EIA-485-A |
| Gradus protectionis | IP20 |
| Temperatura operativa | -20 ad +50 °C cum montatu conductivo thermice documentato; alioquin maxime +40 °C |
| Temperatura servandi et transportandi | −40 ad +70 °C |
| Altitudo Installationis Maxima | 2 000 m supra mare |
| Humiditas relativa | 10% usque ad 93%, non condensans |
| Dimensiones | 320 × 60 × 80 mm |
FREQUENTLY ASKED QUESTIONS
Num 6FB1141-2AT10-3WE2 cum magistro PROFIBUS directe communicare potest?
Controller agit ut servus DP-V0 et datam cyclicam cum magistro classis I intercambiat.
Quae sensoria tutelaris ad 6FB1141-2AT10-3WE2 conecti possunt?
Apparatus supportati includunt sensoria DCOPS, barrierae lucis simplices, margines securitatis et cortinas lucis IEC 61496.
Quae massa ianuae 6FB1141-2AT10-3WE2 regere potest?
Massa ianuae maxima documentata est sexcenti chiliogrammi.
Quae est latitudo aperturae maxima pro 6FB1141-2AT10-3WE2?
Intervalum apertionis ianuae supportatum extenditur usque ad quinque metra.
Quod fasciculum fieldbus utiturur ad integrandum 6FB1141-2AT10-3WE2?
Configuratio PROFIBUS utitur fasciculo descriptionis dispositivi SIEM81BA.GSD.
Quod detallium montis afficit classificationem temperaturae 6FB1141-2AT10-3WE2?
Ad operationem usque ad quinquaginta gradus Celsius requiritur adfixio conductiva thermice ad superficiem metallicam montis vel ad ordinem raillorum specificatum.
Potestne 6FB1141-2AT10-3WE2 motum manualem ianuae adiuvare?
AssistedDrive praebet impulsum motorium ad propulsiones auxiliatas, dum ImpulseDrive initium itineris ex levi impulsu vires capiat.
Compatibility & Ordering Notes
Index Compatibilitatis
- Retine praesentem adressem PROFIBUS, mappationem datorum cyclicorum et configurationem SIEM81BA.GSD.
- Confirma motorem ostii connexum, sensus DCOPS et connexionem dispositivorum protectivorum.
- Serva methodum montandi quae in documentis descripta est, ubi installatio limitem operationis 50 °C requirit.