Siemens SIMATIC PN/PN Coupler 6ES7158-3AD10-0XA0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens • SIMATIC PROFINET Couplers
6ES7158-3AD10-0XA0 SIMATIC PN/PN Coupler
The SIMATIC PN/PN Coupler transfers I/O, safety and record data between two separate PROFINET networks, supporting up to four controllers per subnet, redundant 24 V supply and replaceable SIMATIC BusAdapters.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7158-3AD10-0XA0 |
| Typus Producti | PROFINET subnet-to-subnet data coupler |
| Functio principalis | Exchanges deterministic I/O and records between separate PROFINET networks |
| Applicatio vel series compatibiles | Machines and plant cells requiring controller data exchange while keeping PROFINET subnets separated |
Identificatio exacta.
Match 6ES7158-3AD10-0XA0 character by character and confirm the complete SIMATIC PN/PN Coupler designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The SIMATIC PN/PN Coupler transfers I/O, safety and record data between two separate PROFINET networks, supporting up to four controllers per subnet, redundant 24 V supply and replaceable SIMATIC BusAdapters.
Coupler transfert datis configuratas sine coniunctione duorum subretium Ethernet. Mechanismi I/O, MSI/MSO, PROFIsafe et recensionis dati adiuvant coordinationem inter machinas et inter cellulas.
Key Functions
Retia PROFINET separata
Coupler transfert datis configuratas sine coniunctione duorum subretium Ethernet.
Substitutio flexibilis controlleris
Mechanismi I/O, MSI/MSO, PROFIsafe et recensionis dati adiuvant coordinationem inter machinas et inter cellulas.
Hardware orientatum ad servitium
Connexiones duplicatae pro suppeditatione electrica et BusAdapter substituendi adiuvant installationes retis manutenibiles.
Official Specifications
| Maximus numerus controllerum per subretium | 4 |
|---|---|
| ID Dispositivi PROFINET | 0604H |
| ID vendedoris | 002AH |
| I&M datum | I&M0 al I&M3 |
| Cyclum Isochronum Minimum | 500 µs |
| Commercium Datatum PROFIsafe | Supportata |
| MSI et MSO | Supportata |
| Communicatio Recensui Data | Supportata |
| Longitudo Recensui Maxima | 4 096 octets |
| Profunditas FIFO Recensui | 8 |
| Moduli Accoplationis Recensui | Usque ad 16 |
| Moduli Accoplationis I/O Localis | Usque ad 16 in operatione non-isochrona |
| Tensio nominalis supplicii | 24 V DC |
| AMPLITUDO ADMISSIBILIS FONDIS | 19,2 ad 28,8 V CC |
| Maximus Correntis Ingressus | 360 mA |
| Buffer pro defectu potestatis | 10 ms |
| Gradus praesidium | IP20 |
| Rail de montage | Profilum 7,5 mm aut 15 mm |
Quaestiones Frequenter Rogatae
Quomodo 6ES7158-3AD10-0XA0 retinet duas retes PROFINET separatim?
Uterque latus configuratur ut suum proprium instrumentum in subrete independente, dum tantum data processus assignata transire possunt per copulatorem.
Possuntne data salutis transire per 6ES7158-3AD10-0XA0?
Ita; configura et valida transmissionem PROFIsafe et programmatum salutis completum in utroque latere.
Quae BusAdapters requiruntur pro 6ES7158-3AD10-0XA0?
Elige BusAdapters SIMATIC compatibiles pro mediis physici et dispositione foraminum, quia separatim ordinantur.
Quomodo dominium controlleris assignandum est in 6ES7158-3AD10-0XA0?
Mappare ogni modulo e sottomodulo al controller previsto e mantenere l'assegnazione coerente in entrambi i progetti ingegneristici.
Cosa deve essere salvato prima di sostituire il 6ES7158-3AD10-0XA0?
Salvare entrambe le configurazioni hardware, i nomi dei dispositivi, le impostazioni IP, il mapping dei moduli, i dati di sicurezza e la configurazione del trasferimento record.
Il 6ES7158-3AD10-0XA0 può utilizzare un'alimentazione ridondante da 24 V?
Sì; collegare l'assetto di alimentazione ridondante approvato e testare ciascun alimentatore separatamente.
Cosa deve essere testato dopo la messa in servizio del 6ES7158-3AD10-0XA0?
Verificare i nomi dei dispositivi, le connessioni ai controller, il mapping dei byte, lo stato di qualità, i trasferimenti record, lo scambio di dati di sicurezza e la diagnostica su entrambe le sottoreti.
Compatibility & Ordering Notes
Index Compatibilitatis
- Progettare ciascun lato come un dispositivo PROFINET separato sulla propria sottorete.
- Allineare gli adattatori di bus, la proprietà dei controller e il mapping esatto dei moduli o sottomoduli.
- Validare datos standard, registros et intercambium PROFIsafe in utroque rete.