SIPLUS S7-200 • CPU 224XP

6AG1214-2BD23-2XB0 SIPLUS S7-200 CPU 224XP AC/DC/Relay Compact Controller

AC-powered CPU 224XP controller with fourteen 24 V DC inputs, ten relay outputs and integrated analog I/O.

Ad Primum Aspectum

Nota Siemens
Modellum 6AG1214-2BD23-2XB0
Typus Producti Compact PLC controller
Functio principalis Controlus machinae programmatus
Series Compatible SIPLUS S7-200

Ingressus digitalis et analogus integratus

CPU continet quattuordecim ingressus digitales, decem eggressus relais, duos ingressus analogos et unum eggressum analogum.

Memoria utentis flexibilis

Capacitas programmatum est 12 KB cum editione in modo RUN aut 16 KB sine ea, plus 10 KB dati utentis.

Rete automationis serialis

Duo portus communicationis RS485 suffragant modos operationis PPI, MPI servus et Freeport.

Product Overview

6AG1214-2BD23-2XB0 est controller SIPLUS CPU 224XP AC/DC/relais in familia S7-200. Combinat alimentationem AC cum ingressibus sensorum DC, eggressibus commutationis relais et canalibus analogis integratis.

STEP 7-Micro/WIN praebet ambientes technicos pro hoc controllore. Moduli expansionis, configurationes communicationis et capacitas programmatum utentis simul seligendae sunt pro configuratione machinae.

Focus ordinandi: Adaptare ad supplitum AC et versionem cum relecto exirente, deinde dimensionare programmam, intrinsecos E/O et expansionis potestatis rationem.
Key Functions

Controlus machinae mixti signi

Canalia digitalia et analogica intrinseca signa discreta machinae et valores processus analogicos tractant.

Executio programmatum CPU 224XP

Processus instructiones Booleanas in 0,22 µs exequitur et temporizatores, numeratores et interruptus configurabiles praebet.

Communicationes et expansio S7-200

Duo foramina serialia et subsidium pro usque ad septem modulis expansionis permittunt CPU ut stationem maiorem S7-200 intra suam rationem potestatis constituat.

Official Specifications
Intervallo di alimentazione CA 85–264 V AC
Ingressus Digitales 14 ad 24 V DC
Emissiones Relais 10, usque ad 2 A per exirentem
Relay Switching Voltage 5–30 V DC aut 5–250 V AC
Canalia analogica integrata 2 intradas et 1 extrada
Capacitas programmatum cum editione in modo RUN 12 288 octetis
Capacitas programmatum sine editione in modo RUN 16,384 bytes
Capacitas datorum usoris 10 240 octetis
Executio instructionum Booleanarum 0.22 µs per instructionem
Temporizatores et Numeratores Disponibiles 256 temporizatores et 256 numeratores
Interruptus temporales 2 cum resolutione 1 ms
Numeratio alti velocitatis unifas 4 contadorēs ad 30 kHz et 2 ad 200 kHz
Interfacies Seriales 2 portās RS485
Velōcitātēs datōrum PPI et MPI 9,6; 19,2; et 187,5 kbaud
Velōcitātēs datōrum Freeport 1,2–115,2 kbaud
Modules d'extension maximaux 7
Dimensiones 140 × 80 × 62 mm
Quaestiones Frequenter Rogatae

Quod sōftwāre utendum est ad prōgramma in 6AG1214-2BD23-2XB0 servandum?

Utere STEP 7-Micro/WIN ad prōgramma contrōllēris S7-200 et ad cōnfigūrātiōnēs commūnicātiōnis.

Possuntne ēgressūs relē in 6AG1214-2BD23-2XB0 generāre impulsumōs motūs ad 100 kHz?

High-speed pulse outputs require a DC transistor-output variant rather than the relay-output version.

How much program space remains when I enable RUN-mode editing on 6AG1214-2BD23-2XB0?

The program capacity is 12,288 bytes with RUN-mode editing compared with 16,384 bytes without it.

Can I add seven expansion modules to 6AG1214-2BD23-2XB0?

Up to seven expansion modules are allowed when the CPU and expansion-module power budget is sufficient.

Can I connect a SIWAREX MS weighing module to 6AG1214-2BD23-2XB0?

The CPU is a released SIWAREX MS host, while the weighing module retains its own environmental ratings.

Which serial modes can I use on 6AG1214-2BD23-2XB0?

The RS485 ports support PPI master or slave, MPI slave and configurable Freeport communication.

Does 6AG1214-2BD23-2XB0 provide analog I/O without an expansion module?

The CPU includes two analog inputs and one analog output.

Compatibility & Ordering Notes
Before ordering 6AG1214-2BD23-2XB0: Use the SIPLUS CPU 224XP AC/DC/relay variant and match the existing Micro/WIN project, serial network, relay loads and S7-200 expansion power budget.

Controller replacement preparation

  • Provide the AC supply and 24 V DC input signals for this relay-output variant.
  • Keep the program within the selected RUN-edit memory capacity.
  • Match both RS485 ports to the existing PPI, MPI or Freeport settings.
  • Calculate the expansion power budget and observe each attached module’s own ratings.
Hot Selling Models
TM38233/EZ
ZCD21 XCKD2102P16 019688
EZAMBHXM016M
TV14H236-20z
0822331204
3RG4621-0G02
WT12-P4481E02 1009867
972-0DP01 07V64.001
E11216
3AC433V
3B30-03
3SB3403-1PD
3RT1015-1BB41 3RH1911-1HA12 3RT1916-1EH00
Wago 281-906
BL-U2 BLU2 RS-232C

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.