Overview
Place of Origin: |
Sweden |
Brand Name: |
ABB |
Model Number: |
DO801 3BSE020510R1 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Product Name: |
Digital Output Module |
|
Model: |
DO801 3BSE020510R1 |
|
Dimensions: |
9.3 x 13.6 x 5.1 cm |
|
Weight: |
0.2 kg |
|
Signal Specification: |
24 V DC (12–32 V DC), 0.5 A |
|
Number of Channels: |
16 |
|
Signal Type: |
Current sourcing, current limiting |
|
HART: |
No |
|
SOE: |
No |
|
Redundancy: |
No |
|
High Integrity: |
No |
|
Intrinsic Safety: |
No |
|
Mechanics: |
S800L |
|
Isolation: |
Groupwise isolated from ground |
|
Output Load: |
< 0.4 Ω |
|
Current Limiting: |
Short-circuit proof, current-limited output |
|
Maximum Field Cable Length: |
600 meters (656 yards) |
|
Rated Insulation Voltage: |
50 V |
|
Dielectric Test Voltage: |
500 V AC |
|
Power Dissipation: |
Typ. 2.1 W |
|
Current Consumption +5 V Modulebus: |
80 mA |
|
Current Consumption +24 V Modulebus: |
0 |
|
Current Consumption +24 V External: |
0 |
|
Supported Wire Size: |
Solid: 0.05–2.5 mm², 30–12 AWG; Stranded: 0.05–1.5 mm², 30–12 AWG |
|
Recommended Torque: |
0.5–0.6 Nm |
|
Stripping Length: |
6–7.5 mm (0.24–0.30 inch) |
|
RoHS Status: |
Following EU Directive 2011/65/EU |
|
WEEE Category: |
5. Small Equipment (No External Dimension More Than 50 cm) |
|
Number of Batteries: |
0 |
Description
The DO801 3BSE020510R1 is a 16 channel 24 V digital output module for the S800 I/O. The output voltage range is 10 to 30 volt and the maximum continuous output current is 0.5 A. The outputs are protected against short circuits, over voltage and over temperature. The outputs are in one isolated group. Each output channel consists of a short circuit and over temperature protected high side driver, EMC protection components, inductive load suppression, output state indication LED and optical isolation barrier.
Environment and certification
|
CE Mark: |
Yes |
|
Electrical Safety: |
EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 |
|
Hazardous Location: |
C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2 |
|
Marine Certification: |
ABS, BV, DNV, LR |
|
Operating Temperature: |
0 to +55 °C (+32 to +131 °F), approvals issued for +5 to +55 °C |
|
Storage Temperature: |
-40 to +70 °C (-40 to +158 °F) |
|
Pollution Degree: |
Degree 2, IEC 60664-1 |
|
Corrosion Protection: |
ISA-S71.04: G3 |
|
Relative Humidity: |
5 to 95 %, non-condensing |
|
Max Ambient Temperature: |
55 °C (131 °F), vertical mounting 40 °C (104 °F) |
|
Protection Class: |
IP20 according to IEC 60529 |
|
Mechanical Operating Conditions: |
IEC/EN 61131-2 |
|
EMC: |
EN 61000-6-4, EN 61000-6-2 |
|
Overvoltage Categories: |
IEC/EN 60664-1, EN 50178 |
|
Equipment Class: |
Class I according to IEC 61140 (earth protected) |
|
RoHS Compliance: |
EU RoHS, UAE RoHS, CN RoHS |
|
WEEE Compliance: |
DIRECTIVE/2012/19/EU |
Applications
Fine Chemical and Pharmaceutical Plants:
Used to control hundreds of solenoid valves and mixer contactors. The hot-swappable nature of the S800 I/O ensures replacement of damaged modules without shutting down the plant, maintaining stability in long-cycle chemical production.
Large Food and Beverage Processing Plants:
Drives cylinder switches and inkjet printer trigger signals on high-speed bottling and packaging lines. Its high-density 16-channel design significantly reduces the size of the distributed I/O box.
Water Treatment and Environmental Protection Facilities Plants:
Collects commands distributed across various pump stations to drive pump start/stop and control dosing pump flow. Its stable EMC performance adapts to the electromagnetic environment of frequent starts of high-power equipment.
Features and benefits
16 channels for 24 V d.c. current sourcing outputs
1 isolated groups of 16 channels
Output status indicators
OSP sets outputs to predetermined state upon communication error
Short-circuit protection to ground and 30 V
Over-voltage and overtemperature protection
Process and power connection via detachable connectors
Diagnostics
Front LED’s: S(tatus), Channel 1-16 Status
Status indication of supervision: Module Error, Module Warning, Channel Error
FAQ
Q1: Can the DO801 3BSE020510R1 be connected to an AC 220V load?
A: Absolutely not. Connecting to AC power will instantly burn out the internal power transistors. An intermediate relay must be used for conversion.
Q2: What is the difference between it and the DO801 3BSE020510R1?
A: Both are very similar in function, both providing 16 channels of 24V DC output. The DO801 is a later optimized version with better heat dissipation and overload protection mechanisms.
Q3: Does DO801 3BSE020510R1 support "Fail-safe" settings?
A: Yes. In the event of a communication interruption, its output can be set to "Hold Last State" or "Force Zero (Safe Reset)" via the 800xA system.
Q4: Why is the LED on my DO801 3BSE020510R1 panel lit, but there is no external voltage?
A: The lit LED only indicates that a logic layer instruction has been issued. Please measure the L+ power supply on the terminal block. If L+ is not connected, there will be no voltage at the output.
Q5: What is its maximum total load current of DO801 3BSE020510R1?
A: Although a single channel supports 0.5A, due to module heat dissipation limitations, when all 16 channels are turned on at the same time, the total current is generally recommended not to exceed 5A-8A (see technical manual for details).