SIEMENS · SIMATIC ET 200iSP

6ES7138-7FA00-0AB0 SIMATIC ET 200iSP 4 F-AI Ex HART Electronic Module

The 4 F-AI Ex HART module is a fail-safe SIMATIC ET 200iSP electronic module with four intrinsically safe analog inputs for HART two-wire transmitters.

At a Glance

Brand Siemens
Model 6ES7138-7FA00-0AB0
Product Type Fail-safe intrinsically safe analog input electronic module
Core Function Acquires HART current signals in safety-related hazardous-area applications
Application or Compatible Series SIMATIC ET 200iSP distributed I/O stations

Exact Identification

Match 6ES7138-7FA00-0AB0 character by character and confirm the complete SIMATIC ET 200iSP 4 F-AI Ex HART Electronic Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The 4 F-AI Ex HART module is a fail-safe SIMATIC ET 200iSP electronic module with four intrinsically safe analog inputs for HART two-wire transmitters.

Four safety-related analog channels support process measurements in hazardous-area installations. The input channels support HART communication with compatible two-wire transmitters. The module is specified for applications up to SIL 3, PL e and Category 4 when used in an approved configuration.

Ordering focus: confirm product version 01, the ET 200iSP station configuration, Ex classification, HART transmitter type, loop parameters and required safety level.
Key Functions

Fail-Safe Analog Acquisition

Four safety-related analog channels support process measurements in hazardous-area installations.

HART Device Communication

The input channels support HART communication with compatible two-wire transmitters.

High Safety Integrity

The module is specified for applications up to SIL 3, PL e and Category 4 when used in an approved configuration.

Official Specifications
Product Version 01
Analog Input Channels 4
Input Signal Range 0/4 to 20 mA
Transmitter Connection HART two-wire transmitter
HART Protocol Version 7.0
Functional Safety Level Up to SIL 3 according to IEC 61508:2010
Performance Level PL e according to ISO 13849-1:2015
Safety Category Category 4 according to ISO 13849-1:2015
Gas Ex Classification Ex ib (ia Ga) IIC T4 Gb
Dust Ex Classification Ex ib [ia IIIC Da] IIC T4 Gb
Mining Ex Classification Ex ib [ia] I Mb
Frequently Asked Questions

How many process signals can 6ES7138-7FA00-0AB0 acquire?

Four analog current channels are available for safety-related measurement.

Which signal range is supported by 6ES7138-7FA00-0AB0?

The channels support the 0/4 to 20 mA current range.

Can HART two-wire transmitters be connected to 6ES7138-7FA00-0AB0?

Yes; compatible two-wire transmitters can communicate using HART protocol version 7.0.

What safety integrity can 6ES7138-7FA00-0AB0 support?

An approved installation can be engineered for applications up to SIL 3, PL e and Category 4.

Is 6ES7138-7FA00-0AB0 suitable for intrinsically safe circuits?

Yes; it carries gas, dust and mining intrinsic-safety classifications for the specified installation conditions.

What must be checked before wiring 6ES7138-7FA00-0AB0?

Verify the hazardous-area classification, transmitter type, channel parameters, barriers and grounding concept.

What commissioning checks are important for 6ES7138-7FA00-0AB0?

Validate each current loop, HART address, safety parameter set, diagnostic response and proof-test procedure.

Compatibility & Ordering Notes
Before ordering 6ES7138-7FA00-0AB0: confirm product version 01, the ET 200iSP station configuration, Ex classification, HART transmitter type, loop parameters and required safety level.

Compatibility Checklist

  • Install the electronic module only in an approved SIMATIC ET 200iSP station configuration.
  • Match every connected transmitter and field circuit to the applicable intrinsic-safety parameters.
  • Validate the safety program, channel parameters and proof-test procedure before returning the loop to service.
Hot Selling Models
MZF1-03VPS-KQD
9001KA1
3RH1921-1CA10 E:07 1S/1NO
A2V00002472112
855-0305/0400-1001
MK5900 MKI3020-BPKG/A
3RV1011-1AA10
3RT2016-1BM41
6AV7674-1MB00-0AA0
3NA3832
Allen-Bradley 800F-N3W
SMT-10M-PS-24V-E-2-L-M12
M14640006
3RH2140-1BB40 3RH2911-1HA31 3RT2916-1BB00
BA9043/001 0026988

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.