Siemens SIMOVERT MASTERDRIVES 6SE7036-5GK84-1JC2 IGD8 Inverter Control Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Match the IGD8 module to the installed voltage and current class before removing the original control electronics.
- Record the control-module connections and retain the approved MASTERDRIVES parameter backup for recommissioning.
- Isolate the drive, verify that it is voltage-free and use ESD-safe handling throughout the replacement procedure.
SIEMENS · SIMOVERT MASTERDRIVES 6SE70
6SE7036-5GK84-1JC2 SIMOVERT MASTERDRIVES IGD8 Inverter Control Module
This Siemens IGD8 spare module provides inverter-control hardware for devices rated 500-690 V three-phase AC at 50/60 Hz and 675-930 V DC in the specified 860 A and 1580 A equipment classes.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE7036-5GK84-1JC2 |
| Product Type | Drive-system spare part |
| Core Function | Restores configured inverter-control hardware in the assigned high-current drive equipment |
| Application or Compatible Series | SIMOVERT MASTERDRIVES 6SE70 systems |
Exact Identification
Match 6SE7036-5GK84-1JC2 character by character and confirm the complete SIMOVERT MASTERDRIVES IGD8 Inverter Control Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
This Siemens IGD8 spare module provides inverter-control hardware for devices rated 500-690 V three-phase AC at 50/60 Hz and 675-930 V DC in the specified 860 A and 1580 A equipment classes.
The module is a replacement inverter-control component for the designated SIMOVERT MASTERDRIVES equipment rather than a complete converter. The documented device classes cover 500-690 V three-phase AC at 50/60 Hz and 675-930 V DC. The compatible equipment ratings identified for this spare module are 860 A and 1580 A.
Key Functions
IGD8 Control Hardware
The module is a replacement inverter-control component for the designated SIMOVERT MASTERDRIVES equipment rather than a complete converter.
AC and DC Equipment Classes
The documented device classes cover 500-690 V three-phase AC at 50/60 Hz and 675-930 V DC.
High-Current Application Match
The compatible equipment ratings identified for this spare module are 860 A and 1580 A.
Official Specifications
| Module Designation | IGD8 |
|---|---|
| Hardware Role | Inverter control module |
| Applicable AC Device Voltage | 500-690 V AC |
| AC Supply Topology | Three-phase AC |
| Applicable Line Frequency | 50/60 Hz |
| Applicable DC Device Voltage | 675-930 V DC |
| Associated Current Ratings | 860 A and 1580 A |
| Packaging Dimensions | 69 × 16 × 6 cm |
| Net Weight | 0.36 kg |
| Product Construction Class | Customer-order engineered spare component |
Frequently Asked Questions
Is 6SE7036-5GK84-1JC2 a complete inverter?
No, the item is the IGD8 inverter-control spare module for the designated drive equipment.
Which AC voltage class is supported by 6SE7036-5GK84-1JC2?
The associated equipment class is 500-690 V three-phase AC at 50/60 Hz.
Which DC voltage class is supported by 6SE7036-5GK84-1JC2?
The associated DC equipment range is 675-930 V DC.
Which current ratings are associated with 6SE7036-5GK84-1JC2?
The identified high-current equipment ratings are 860 A and 1580 A.
How should I select 6SE7036-5GK84-1JC2 for a replacement?
Match the complete spare-part number, IGD8 designation, voltage class, current rating and installed connector arrangement.
How much shipping space is listed for 6SE7036-5GK84-1JC2?
The packaged module measures 69 × 16 × 6 cm and has a net weight of 0.36 kg.
What should be done before installing 6SE7036-5GK84-1JC2?
Qualified personnel should isolate the drive, verify that it is voltage-free, record the existing connections and use ESD-safe handling.