Siemens 6SL3217-0CE17-5UA1 SINAMICS V10 0.75 kW Inverter
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use a three-phase 400 V supply and the required upstream fuse arrangement.
- Enter the motor data and select the appropriate V/f or flux-current control mode during commissioning.
- Observe the pulse-frequency, temperature and altitude derating requirements for the chosen operating point.
- Keep motor cables within the frame-A limits and add the specified reactor when an extended cable run is required.
6SL3217-0CE17-5UA1 SINAMICS V10 0.75 kW Inverter
A frame-size A SINAMICS V10 inverter rated for a 0.75 kW motor, with three-phase 400 V input and configurable control I/O.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3217-0CE17-5UA1 |
| Product Type | Variable-frequency inverter |
| Core Function | Adjustable-speed motor operation |
| Application | Three-phase squirrel-cage induction motors |
Selectable motor-control curves
Linear V/f, quadratic V/f and flux-current control provide different motor-control characteristics for the connected load.
Configurable machine signals
Three digital inputs, one analog input, one analog output and one relay output provide configurable control signals.
Panel-based commissioning
The removable operator panel supports local parameter setup and can be mounted separately on a cabinet door.
Product Overview
6SL3217-0CE17-5UA1 controls a three-phase induction motor using linear V/f, quadratic V/f or flux-current control.
The frame-size A drive combines a removable operator panel with configurable digital and analog signals, programmable frequency selections and DC or compound braking for machine speed-control tasks.
Key Functions
Selectable motor-control curves
Linear V/f, quadratic V/f and flux-current control provide different motor-control characteristics for the connected load.
Configurable machine signals
Three digital inputs, one analog input, one analog output and one relay output provide configurable control signals.
Panel-based commissioning
The removable operator panel supports local parameter setup and can be mounted separately on a cabinet door.
Official Specifications
| Rated motor power | 0.75 kW |
|---|---|
| Supply | Three-phase 400 V AC, −15% to +15% |
| Input frequency | 50 Hz ±3%; stated range 48–52 Hz |
| Rated input current | 2.4 A |
| Rated output current | 2.2 A |
| Output-frequency range | 0–300 Hz |
| Overload capability | 150% of rated load current for 60 s in a 300 s cycle |
| Pulse frequency | 2–16 kHz; default 4 kHz |
| Digital inputs | 3 programmable, optically isolated |
| Analog input | 1 programmable; 0–10 V or 0–20 mA |
| Analog output | 1 programmable; 0–10 V or 0–20 mA |
| Relay output | 1 programmable; 250 V AC/2 A inductive or 30 V DC/5 A resistive |
| Braking methods | DC braking and compound braking |
| Frame and dimensions | Frame A; 230 × 140 × 155 mm including operator panel |
| Weight | 2.2 kg including operator panel |
| Cooling | Natural convection |
| Operating temperature | 0–50 °C without derating; derating from 50 to 60 °C |
| Protection rating | IP21 housing; terminal blocks IP00 |
| Motor cable without reactor | Up to 30 m shielded or 50 m unshielded |
| Motor cable with reactor | Up to 60 m shielded or 100 m unshielded |
Frequently Asked Questions
Can 6SL3217-0CE17-5UA1 run from a single-phase 230 V supply?
The drive requires a three-phase 400 V AC supply within its permitted voltage tolerance.
What motor rating is appropriate for 6SL3217-0CE17-5UA1?
The model is rated for a 0.75 kW three-phase squirrel-cage induction motor with a rated drive output current of 2.2 A.
How long can 6SL3217-0CE17-5UA1 supply a 150 percent overload?
The specified overload capability is 150% of rated load current for 60 seconds within a 300-second cycle.
Can I use a 0–20 mA speed command with 6SL3217-0CE17-5UA1?
The programmable analog input accepts either 0–10 V or 0–20 mA.
Does 6SL3217-0CE17-5UA1 need forced-air cooling in frame A?
The frame-size A drive uses natural convection cooling.
When should I add an output reactor to 6SL3217-0CE17-5UA1?
An output reactor is needed to use the extended frame-A motor-cable limits of 60 m shielded or 100 m unshielded.
Can I operate 6SL3217-0CE17-5UA1 at 55 degrees Celsius without reducing load?
Operation above 50 °C requires derating within the permitted range up to 60 °C.