Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6sl3210 1pe12 8ul1 sinamics g120 pm240 2 power module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SL3210-1PE12-8UL1 SINAMICS G120 PM240-2 Power Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SINAMICS G120 PM240-2

6SL3210-1PE12-8UL1 SINAMICS G120 PM240-2 Power Module

An internally air-cooled FSA power module with 0.75 kW LO and 0.55 kW HO ratings.

At a Glance

Brand Siemens
Model 6SL3210-1PE12-8UL1
Product Type Converter power module
Core Function Variable-frequency motor power conversion
Application Compact modular G120 installations

Compact power-section configuration

The FSA arrangement combines a narrow footprint with separate line and motor terminals.

Cabinet thermal planning

Internal air cooling requires a defined airflow and duty-dependent ambient conditions.

Motor-duty matching

LO and HO ratings establish the continuous output-power and current limits.

Product Overview

6SL3210-1PE12-8UL1 provides a PM240-2 power section for a compact modular converter assembly.

The selected configuration combines duty-dependent output ratings with internal air cooling, plug-in power terminals and different shielded and unshielded motor-cable limits.

Ordering focus: Match the power-module configuration, operating duty, Control Unit and cabinet thermal design.
Key Functions

Compact power-section configuration

The FSA arrangement combines a narrow footprint with separate line and motor terminals.

Cabinet thermal planning

Internal air cooling requires a defined airflow and duty-dependent ambient conditions.

Motor-duty matching

LO and HO ratings establish the continuous output-power and current limits.

Official Specifications
Line supply 3-phase AC, 380–480 V ±10%; 47–63 Hz
Input current by duty LO: 2.9 A; HO: 2.6 A
Rated output power LO: 0.75 kW; HO: 0.55 kW
Rated output current LO: 2.2 A; HO: 1.7 A
Maximum output current 3.4 A
Pulse frequency 4 kHz
Output-frequency limits Vector control: 0–200 Hz; V/f control: 0–550 Hz
Low-overload duty 150% for 3 s and 110% for 57 s in a 300 s cycle
High-overload duty 200% for 3 s and 150% for 57 s in a 300 s cycle
Power factor and efficiency Power factor 0.85; efficiency 96%
Nominal power loss 40 W
Cooling airflow Internal air cooling; required airflow 0.005 m³/s
Operating ambient by duty LO: −10 to +40 °C; HO: −10 to +50 °C
Transport and storage ambient −25 to +55 °C
Installation altitude 1,000 m
Maximum operating humidity 95% RH, without condensation
Power terminals Plug-in screw terminals for line and motor; 1–2.5 mm² conductors
Maximum motor-cable length 50 m shielded; 100 m unshielded
Protection and frame IP20 / UL open type; FSA
Dimensions and net mass 73 × 196 × 165 mm (W × H × D); 1.4 kg
Frequently Asked Questions

Will 0.003 m³/s of cooling air meet the stated requirement for 6SL3210-1PE12-8UL1?

The specified cooling-air requirement is 0.005 m³/s.

How much nominal heat loss should I include for 6SL3210-1PE12-8UL1 in a cabinet calculation?

The stated nominal power loss is 40 W.

Can 6SL3210-1PE12-8UL1 operate in an environment where condensation occurs?

The maximum stated humidity is 95% RH with condensation excluded.

Which storage-temperature interval applies to 6SL3210-1PE12-8UL1?

The storage ambient range is −25 to +55 °C.

At what installation altitude is 6SL3210-1PE12-8UL1 specified?

The stated installation altitude is 1,000 m.

Which output-frequency ceiling applies to 6SL3210-1PE12-8UL1 when V/f control is used?

The V/f output-frequency range extends to 550 Hz.

What supply power factor is specified for 6SL3210-1PE12-8UL1?

The specified power factor is 0.85.

Compatibility & Ordering Notes
Before ordering 6SL3210-1PE12-8UL1: Match the power-module configuration, operating duty, Control Unit and cabinet thermal design.

Before installation

  • Match the power module to the installed G120 Control Unit and drive configuration.
  • Allow the specified cooling airflow and nominal heat loss in the enclosure design.
  • Select LO or HO duty and apply its corresponding ambient and current limits.
  • Keep the installation dry and the power and motor cables within their stated limits.
Hot Selling Models
P1533B074001
3RV1031-4AA10
UHV240-AS/AS
5SV3644-6
9956061503
17-REL/KSR-W230/21-21-LC
6ES5544-3UA11 6ES5752-0AA23
MOD13/1X013-24
OG-50T-PU6
Z4K 236-02Z-M20
1507803 SAC-5P-M12MS
ZB5AP2
6ES5544-3UA11 6ES5752-0AA12
5SX21 B10
PXLC6/1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.