Overview
Siemens · SIMATIC S7-300
6ES7322-1CF00-0AA0 SM 322 Digital Output Module
Siemens 6ES7322-1CF00-0AA0 is the SIMATIC S7-300 SM 322 isolated digital output module with eight protected outputs for 48 to 125 V DC loads at up to 1.5 A per active channel.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7322-1CF00-0AA0 |
| Product Type | Isolated high-voltage digital output module |
| Core Function | Switches DC actuators from the programmable controller |
| Application or Compatible Series | SIMATIC S7-300 and ET 200M stations |
Load Circuit
Confirm the field supply, actuator voltage and load current for each output group.
Connector Transfer
Move the twenty-pole front connector only after recording channel allocation and polarity.
Protection Check
Maintain the specified quick-response fusing and short-circuit protection arrangement.
Product Overview
Siemens 6ES7322-1CF00-0AA0 is the SIMATIC S7-300 SM 322 isolated digital output module with eight protected outputs for 48 to 125 V DC loads at up to 1.5 A per active channel.
The output stage controls 48 to 125 V DC actuators such as solenoid valves and DC contactors. Channels are electrically isolated from the backplane bus and arranged in groups of four. Electronic short-circuit protection and a group fault indication support fault handling.
Key Functions
High-Voltage DC Switching
The output stage controls 48 to 125 V DC actuators such as solenoid valves and DC contactors.
Grouped Isolation
Channels are electrically isolated from the backplane bus and arranged in groups of four.
Electronic Output Protection
Electronic short-circuit protection and a group fault indication support fault handling.
Official Specifications
| Number of Digital Outputs | 8 |
|---|---|
| Load-Voltage Range | 40 to 140 V DC |
| Rated Output Current per Channel | 1.5 A |
| Minimum Active Load Current | 10 mA |
| Maximum Surge Current | 3 A for 10 ms |
| Maximum Residual Current at Signal 0 | 0.5 mA |
| Short-Circuit Response Threshold | 4.4 A typical |
| Output Voltage at Signal 1 | At least L+ minus 1.2 V |
| Maximum Lamp Load at 48 V | 15 W |
| Maximum Lamp Load at 125 V | 40 W |
| Turn-On Delay with Resistive Load | 2 ms maximum |
| Turn-Off Delay with Resistive Load | 15 ms maximum |
| Maximum Resistive-Load Switching Frequency | 25 Hz |
| Maximum Inductive-Load Switching Frequency | 0.5 Hz |
| Maximum Lamp-Load Switching Frequency | 10 Hz |
| Backplane Current at 5 V DC | 100 mA maximum |
| No-Load Current from L+ | 2 mA maximum |
| Typical Power Loss | 7.2 W |
| Isolation Test Voltage | 1,500 V AC |
| Front Connector | 1 x 20-pole |
Frequently Asked Questions
hsangWhich actuators can I wire to 6ES7322-1CF00-0AA0?
Use compatible 48-to-125-volt DC loads such as solenoid valves, DC contactors and indicator lamps within the channel rating.
How are the outputs of 6ES7322-1CF00-0AA0 isolated?
The channels are isolated from the backplane and electrically separated in groups of four.
What fuse should protect 6ES7322-1CF00-0AA0?
Use the specified quick-response 6.3-ampere, 250-volt, 5-by-20-millimetre fuse arrangement.
Can two channels of 6ES7322-1CF00-0AA0 control one redundant load?
Yes, two outputs from the same group may be used for redundant load control.
Why should I check minimum load current on 6ES7322-1CF00-0AA0?
An active channel requires at least ten milliamperes to remain within its specified operating range.
What must be recorded before replacing 6ES7322-1CF00-0AA0?
Record the twenty-pole connector wiring, output groups, field-supply polarity and actuator ratings.
How quickly does 6ES7322-1CF00-0AA0 switch a resistive load?
The maximum delays are two milliseconds when turning on and fifteen milliseconds when turning off.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm every connected actuator remains within the module voltage, current, surge and switching-frequency limits.
- Preserve the two groups of four channels and their field-supply polarity when transferring wiring.
- Check the quick-response fuse and electronic short-circuit protection before energizing the outputs.