Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7232 4hb30 0xb0 simatic s7 1200 sm 1232 analog output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7232-4HB30-0XB0 SIMATIC S7-1200 SM 1232 Analog Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC S7-1200

6ES7232-4HB30-0XB0 SIMATIC S7-1200 SM 1232 Analog Output Module

SM 1232 with two analog outputs, fourteen-bit bipolar voltage conversion or thirteen-bit current conversion, and output-circuit diagnostics.

At a Glance

Brand Siemens
Model 6ES7232-4HB30-0XB0
Product Type Two-channel analog output module
Core Function Voltage or current command output
Application S7-1200 process and actuator control

Voltage command signals

Bipolar ten-volt outputs provide fourteen-bit conversion for analog command circuits.

Current-loop command signals

Zero-to-twenty-milliampere outputs provide thirteen-bit conversion for current-operated equipment.

Output diagnostics

Supply monitoring, wire-break and short-circuit diagnostics assist maintenance of the output circuits.

Product Overview

6ES7232-4HB30-0XB0 adds two analog command channels to a SIMATIC S7-1200 station.

Each output function uses the specified voltage or current range, with separate load-impedance requirements and diagnostics for output and supply conditions.

Ordering focus: Select voltage or current operation, connected-load impedance and the required front connector.
Key Functions

Voltage command signals

Bipolar ten-volt outputs provide fourteen-bit conversion for analog command circuits.

Current-loop command signals

Zero-to-twenty-milliampere outputs provide thirteen-bit conversion for current-operated equipment.

Output diagnostics

Supply monitoring, wire-break and short-circuit diagnostics assist maintenance of the output circuits.

Official Specifications
Rated supply 24 V DC
Typical supply current 45 mA
Typical backplane current 80 mA at 5 V DC
Typical power loss 1.5 W
Output channels 2 current or voltage outputs
Voltage range and resolution −10 to +10 V; 14 bits
Current range and resolution 0–20 mA; 13 bits
Voltage-mode load impedance Minimum 1000 Ω
Current-mode load impedance Maximum 600 Ω
Basic accuracy at 25°C ±0.3% of range for voltage and current
Accuracy up to 55°C ±0.6% of total measurement range
Common-mode voltage limit 12 V
Diagnostic functions Supply monitoring, wire break and short circuit; diagnostic alarm
Status indication Output status and maintenance LEDs
Front connection Front connector required
Operating ambient 0 to +55°C horizontal; 0 to +45°C vertical
Storage and transport ambient −40 to +70°C
Maximum humidity 95% at 25°C, non-condensing
Enclosure protection IP20
Dimensions and approximate weight 45 × 100 × 75 mm (W × H × D); 180 g
Frequently Asked Questions

Can I drive a five-hundred-ohm current-loop load from 6ES7232-4HB30-0XB0?

The current-output load limit is six hundred ohms, so a five-hundred-ohm load lies within that limit.

Can I connect a five-hundred-ohm load in voltage mode to 6ES7232-4HB30-0XB0?

Voltage operation requires a load impedance of at least one thousand ohms.

Does current mode on 6ES7232-4HB30-0XB0 retain fourteen-bit resolution?

Current output has thirteen-bit resolution, while voltage output has fourteen-bit resolution.

Which bipolar command range can 6ES7232-4HB30-0XB0 generate?

The voltage-output range extends from minus ten to plus ten volts.

What connector must be present to wire the outputs of 6ES7232-4HB30-0XB0?

A front connector is required for the module wiring.

Which output faults can 6ES7232-4HB30-0XB0 report?

The module provides wire-break and short-circuit diagnostics together with supply-voltage monitoring.

Can I use the fifty-five-degree ambient limit when 6ES7232-4HB30-0XB0 is installed vertically?

Vertical installation has a maximum operating ambient temperature of forty-five degrees Celsius.

Compatibility & Ordering Notes
Before ordering 6ES7232-4HB30-0XB0: Select voltage or current operation, connected-load impedance and the required front connector.

Before installation

  • Match the module to the S7-1200 station and select the intended output mode.
  • Use the appropriate minimum voltage-load or maximum current-load impedance.
  • Include the external supply and backplane current in the station power budget.
  • Provide the required front connector and observe the orientation-dependent ambient limit.
Hot Selling Models
AD1S-B2-AO-DN-HA-61
ABB MS132-0.25T 1SAM340000R1002
STEP-PS-100-240AC/12DC/3
OGU121P3K-TSSL
194E-E32-1753-6N
7104 087 5389.2 IOP-90 7104 089 02471
QUINT4-PS​​/1AC/24DC/2.5/PT
EPT011592
IBSIL24BKRB-LK
CE770L
051151 3P+N+E
0448360000
FS401 MB13 FS401M-B13/0.03
3RA2315-8XB30-1AP0
FAZ-C10/2-NA

Get a Free Quote