- Match the installed I/O module to BaseUnit type B1.
- Use the I/O module’s process-terminal assignment and dedicated supply arrangement.
- Keep the process-terminal current within 5 A and the bus currents within 10 A.
- Account for the supply isolation exception at terminals 9–12.
- Do not plan external P1/P2/AUX bus access or system shield terminals on this base.
- Allow 20 mm width and apply the installation-position temperature limit.
6ES7193-6BP20-0BB1 SIMATIC ET 200SP BU20-P12+A0+4B B1 BaseUnit
A 20 mm B1 BaseUnit with 12 push-in process terminals, separate supply terminals and continued potential buses, without external access to the P1, P2 or AUX busbars.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7193-6BP20-0BB1 |
| Product Type | Dark-colored B1 BaseUnit |
| Core Function | Providing process and dedicated supply connections |
| Application | ET 200SP modules requiring BaseUnit type B1 |
Dedicated supply points
The 1L/2L and 1N/2N connections supply the installed module.
Continued busbars
P1, P2 and AUX remain connected to the adjacent BaseUnit on the left.
No shield bracket
This BaseUnit is not suitable for the system shield-connection terminals.
Product Overview
6ES7193-6BP20-0BB1 provides the BU20-P12+A0+4B wiring base for ET 200SP I/O modules requiring BaseUnit type B1, using push-in terminals and a 20 mm slot width.
The base continues the existing potential group but provides the module’s dedicated supply connections separately from the inaccessible P1, P2 and AUX busbars.
Key Functions
Provide module-specific process and supply connections
The installed I/O module defines the twelve process-terminal assignments, with 1L/2L and 1N/2N used for the dedicated module supply.
Continue the existing potential group
The self-assembling P1, P2 and AUX buses connect to the BaseUnit on the left without external busbar terminal access.
Preserve the B1 mechanical and isolation arrangement
The base uses automatic coding and the B1 isolation arrangement, with the process-to-supply isolation exception applying to terminals 9–12.
Official Specifications
| Rated DC Bus and Process Voltage | 24 V DC |
|---|---|
| Rated AC Bus and Process Voltage | 230 V AC |
| Maximum P1/P2 and AUX Bus Current | 10 A |
| Maximum Process-Terminal Current | 5 A |
| Field-Terminal Construction | Push-in |
| Process-Terminal Count | 12 per slot |
| Dedicated Module Supply Connections | 1L and 2L; 1N and 2N |
| External Busbar and AUX Access | No terminal access to P1, P2 or AUX; no add-on terminals |
| Mechanical Coding and Slot Count | Automatic coding; one module slot |
| Insulation Test Voltage | 3100 V DC |
| Process-to-Supply Isolation | Provided except at process terminals 9–12 |
| Conductor Cross-Section | 0.14–2.5 mm²; AWG 26–14 |
| Horizontal Operating Temperature | −30 to +60 °C |
| Vertical Operating Temperature | −30 to +50 °C |
| Standard Maximum Installation Altitude | 2000 m above sea level |
| Minimum Dew Point | −60 °C; suitable for dry-room applications |
| Dimensions (Width × Height × Depth) | 20 × 117 × 35 mm |
| Approximate Weight | 48 g |
Frequently Asked Questions
Can I feed the station P1 and P2 buses through the module supply terminals of 6ES7193-6BP20-0BB1?
The dedicated module supply terminals do not provide external access to the P1, P2 or AUX busbars.
Which module type belongs on 6ES7193-6BP20-0BB1?
Use an ET 200SP I/O module requiring BaseUnit type B1.
Where is the AC module supply connected on 6ES7193-6BP20-0BB1?
The supply uses 1L and 2L for line and 1N and 2N for neutral or ground, rated up to 230 V AC and 10 A.
Are all process terminals on 6ES7193-6BP20-0BB1 isolated from the supply?
The process-to-supply isolation exception applies to terminals 9–12.
Can I attach the system shield-connection terminals to 6ES7193-6BP20-0BB1?
This BaseUnit is not suitable for those shield-connection terminals.
Does 6ES7193-6BP20-0BB1 separate the potential group from the BaseUnit on its left?
The P1, P2 and AUX buses continue from the adjacent BaseUnit on the left.
How do I determine which wire belongs at each process terminal of 6ES7193-6BP20-0BB1?
The installed I/O module determines the assignment of terminals 1–12.