Overview
- Provide the required Micro Memory Card for this original interface generation.
- Configure with STEP 7 V5.3 SP1 or later and the applicable GSD file.
- Assign the PROFINET device name before startup.
- Keep the ET 200S station within 63 modules and 2 m total width.
- Include the terminating module and the installed power-module arrangement.
6ES7151-3AA00-0AB0 SIMATIC ET 200S IM151-3 PN Interface Module
An IM151-3 PN interface with two Ethernet ports, 100 Mbit/s full-duplex transmission and support for up to 63 station modules.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7151-3AA00-0AB0 |
| Product Type | Distributed-I/O interface module |
| Core Function | Linking an I/O station to its controller |
| Application | ET 200S PROFINET IO stations |
Connect distributed I/O over Ethernet
The interface uses 100BASE-TX with two RJ45 ports and autonegotiation.
Build a modular ET 200S station
Up to 63 power, electronic or motor-starter modules can be connected within a 2 m station width.
Identify supply and communication faults
LINK, BF, SF and ON indicators support local checks of the station and network.
Product Overview
6ES7151-3AA00-0AB0 connects ET 200S power, electronic and motor-starter modules to a PROFINET IO controller.
The station can contain up to 63 modules across a maximum width of 2 m, with LED diagnostics and a terminating module included in the interface-module scope.
Key Functions
Connect distributed I/O over Ethernet
The interface uses 100BASE-TX with two RJ45 ports and autonegotiation.
Build a modular ET 200S station
Up to 63 power, electronic or motor-starter modules can be connected within a 2 m station width.
Identify supply and communication faults
LINK, BF, SF and ON indicators support local checks of the station and network.
Official Specifications
| Transmission Method | 100BASE-TX |
|---|---|
| Maximum Transmission Rate | 100 Mbit/s, full duplex |
| Ethernet Connections | 2 RJ45 ports with autonegotiation |
| Maximum Station Expansion | 63 power, electronic or motor-starter modules; up to 2 m width |
| Input and Output Address Space | 256 bytes of inputs and 256 bytes of outputs |
| Maximum Supply Current from 1L+ | 200 mA |
| Typical Power Loss | 2 W |
| Supply-Failure Bridging Time | 20 ms |
| Network Services | SNMP, ping and ARP |
| Diagnostic Indicators | LINK, BF (red), SF (red) and ON (green) |
| Electrical Isolation | Ethernet isolated from electronics |
| Isolation Test Voltage | 500 V DC |
| Dimensions (W × H × D) | 45 × 119.5 × 75 mm |
| Approximate Weight | 135 g |
Frequently Asked Questions
Does 6ES7151-3AA00-0AB0 need an MMC for operation?
A Micro Memory Card is required for this interface generation.
Which STEP 7 release can configure 6ES7151-3AA00-0AB0?
Use STEP 7 V5.3 with Service Pack 1 or later and the supplied GSD file.
How many station modules can I connect to 6ES7151-3AA00-0AB0?
The interface supports up to 63 power, electronic or motor-starter modules within a maximum station width of 2 m.
Do I need to assign a device name before commissioning 6ES7151-3AA00-0AB0?
The IO device must be assigned a device name before PROFINET IO commissioning.
What controller state is required when commissioning 6ES7151-3AA00-0AB0?
The IO controller must be powered and in RUN before the ET 200S station is commissioned.
Which local indicators help diagnose 6ES7151-3AA00-0AB0?
The module provides LINK, bus-fault BF, group-error SF and supply ON indicators.
Is a terminating module included with 6ES7151-3AA00-0AB0?
The interface-module scope includes the terminating module.