Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

PM891K01 36BSE053241R1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Value

Model

PM891K01 36BSE053241R1

Product Type

Processor Unit

Dimensions

20 x 18.7 x 10 cm

Weight

1.64 kg

Redundancy

No

High Integrity

No

Clock Frequency

450 MHz

Performance (1000 boolean operations)

0.043 ms

Performance

0.043 ms

Memory

256 MB

RAM available for application

208.985 MB

Flash memory for storage

Yes

Processor type

MPC8270

Switch over time (redundant configuration)

Max 10 ms

Applications per controller

32

Programs per application

64

Diagrams per application

128

Tasks per controller

32

Number of cycle times

32

Cycle time per application program

Down to 1 ms

Firmware storage (Flash PROM)

16 MB

Power supply

24 V DC (19.2–30 V DC)

Power consumption (typ/max)

660 / 750 mA

Power dissipation

15.8 W (18 W max)

Redundant power supply status input

Yes

Built-in backup battery

No

Clock synchronization

1 ms (CNCP protocol between AC 800M controllers)

Event queue per OPC client

Up to 3000 events

Transmission speed to OPC server

36–86 events/sec, 113–143 data messages/sec

CEX bus communication modules

12

CEX bus supply current

Max 2.4 A

I/O clusters (non-redundant CPU)

0 electrical + 7 optical

I/O clusters (redundant CPU)

0 electrical + 7 optical

I/O capacity (Modulebus)

Max 84 modules

Modulebus scan rate

0–100 ms

Electrical Modulebus supply current (24 V)

Max 1.0 A

Electrical Modulebus supply current (5 V)

Max 1.5 A

Ethernet channels

2

Ethernet interface

10/100 Mbit/s

Control Network protocol

MMS / IAC

Recommended Control Network backbone

100 Mbit/s switched Ethernet

Real-time clock stability

50 ppm (~0.5 h/year)

RS-232C interfaces

1 (COM4 service tool)

COM3 (RS-232C)

Not supported

COM4 (RS-232C)

9600 baud, RJ-45, opto-isolated, no RTS-CTS

Description

The PM891K01 36BSE053241R1 processor is a monolithic unit equipped with power supply, CPU-boards and unit termination. The unit contains microprocessor and RAM memory, a real-time clock, LED indicators, INIT push button and a Secure Digital interface. The PM891 does not contain any internal battery The PM891 has two RJ45 Ethernet ports (CN1, CN2) for connection to the Control Network, and one RJ45 serial port (COM4). The COM4 port is isolated and used for a configuration tool. The PM891K01 36BSE053241R1 supports CPU redundancy for higher availability (CPU, CEX-Bus, communication interfaces and S800 I/O).

Environment and certification

Parameter

Value

Operating Temperature

0 to +55 °C (+32 to +131 °F)

Storage Temperature

-40 to +70 °C (-40 to +158 °F)

Temperature Change Rate

3 °C/min (IEC/EN 61131-2)

Pollution Degree

Degree 2 (IEC/EN 61131-2)

Corrosion Protection

G3 (ISA 71.04 compliant)

Relative Humidity

5 to 95%, non-condensing

Emitted Noise

Not specified

Vibration (10–50 Hz)

0.0375 mm amplitude

Vibration (50–150 Hz)

0.5 g acceleration

Vibration (5–500 Hz)

0.2 g acceleration

Rated Isolation Voltage

50 V

Dielectric Test Voltage

500 V AC

Protection Class

IP20 (EN 60529, IEC 529)

Altitude Rating

Up to 2000 m (IEC/EN 61131-2)

EMC Emission & Immunity

EN 61000-6-4 / EN 61000-6-2

Environmental Conditions

Industrial

CE Mark

Yes

Electrical Safety Standards

EN 50178, IEC 61131-2, UL 61010-1, UL 61010-2-201

Hazardous Location Approval

UL 60079-15; cULus Class 1, Zone 2; AEx nA IIC T4; Ex nA IIC T4 Gc X

Marine Certifications

ABS, BV, DNV-GL, LR

TÜV Approval

No

RoHS Compliance

EU RoHS, UAE RoHS, CN RoHS

WEEE Compliance

Directive 2012/19/EU

Applications

Large-scale petrochemical plants: Used to control extremely complex, plant-wide interlocking systems with massive data volumes.

Supercritical/ultra-high voltage power plants: Serving as the core DCS controller, managing massive amounts of real-time analog signals and control loops.

Large offshore drilling platforms: Used in space-constrained environments with extremely high requirements for integration and processing speed.

Modern pulp and paper mills: Handling the coordinated control of ultra-large-scale fully automated papermaking lines.

Large-scale data center power stations: Managing highly intensive power monitoring and cooling linkage systems.

Features and benefits

Reliability and simple fault diagnosis procedures

Modularity, allowing for step-by-step expansion

IP20 Class protection without the requirement for enclosures

The controller has full EMC certification

High performance and large application memory

Sectioned CEX-Bus using a pair of BC810

Built-in redundant Ethernet Communication ports

FAQ

Q: Can the PM891K01 36BSE053241R1 be directly plugged into an older TP830 baseboard?
A: No. The PM891 requires a dedicated TP891 baseboard with different pin definitions and physical dimensions.

Q: What is the biggest advantage of the PM891K01 36BSE053241R1?
A: Its core advantages are its massive 256MB of memory and battery-free program and data backup, unique in the AC 800M series.

Q: How many I/O signals does the PM891K01 36BSE053241R1 support?
A: Due to its large memory, it can easily support over 5000 I/O points, with the specific upper limit depending on the communication scan cycle requirements.

Q: Can the status lights and information on the screen of the PM891K01 36BSE053241R1 be customized?
A: The screen mainly displays preset system diagnostic information (such as IP address, firmware version, and operating status), and cannot be customized like an HMI.

Q: What precautions should be taken when replacing the PM891K01 36BSE053241R1?
A: Ensure that the firmware of the new module is compatible with the existing software engineering of the control station, as the PM891 typically requires a higher version of the ABB system environment.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.