Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000

Pro SIEMENS

Pagina prima>Producta>Pro SIEMENS

Siemens SIMOVERT MV 6SY8102-0LA02 UEL2 Electronic Module

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

SIEMENS SIMOVERT MV · UEL2 ELECTRONIC MODULE

6SY8102-0LA02 SIMOVERT MV UEL2 ELECTRONIC MODULE

UEL2 electronic module used for monitored auxiliary supplies and crowbar-gating signal paths in SIMOVERT MV medium-voltage drive converters.

Ad Primum Aspectum

Nota Siemens
Modellum 6SY8102-0LA02
Typus Producti UEL2 electronic module
Functio principalis Monitors auxiliary supply status and transfers crowbar-gating signals
Applicatio vel series compatibiles SIMOVERT MV medium-voltage drive converters
Identificatio exacta. Match the complete article number and UEL2 assembly designation.
Supply Check Confirm the upstream 24 V feed and both monitored internal supply channels.
Signal-Path Check Verify module position, X1 connection, and fiber-optic routing before replacement.
Product Overview

Siemens documents the UEL module as part of the SIMOVERT MV medium-voltage converter control and crowbar system. The exact product photographs identify this assembly as UEL2 with article number 6SY8102-0LA02.

In the standard configuration the UEL assembly is designated A300; a parallel converter configuration adds a second UEL at A400. The maintenance instructions identify monitored 5 V and 12 V internal supplies and fiber-optic crowbar-gating links from A181 and A182.

Focus ordinandi: match the complete article number, UEL2 marking, cabinet position, connector path, and fiber-optic routing before replacement.

Key Functions

Auxiliary-Supply Monitoring

Monitors the internal 5 V and 12 V supply channels derived from the upstream 24 V supply.

Crowbar-Gating Signal Interface

Carries the upper and lower DC-link crowbar-gating paths through fiber-optic connections.

Fault Localization

Provides separate diagnostic fault messages for the A300 module and for the additional A400 module in parallel systems.

Serviceable Module Connection

Uses a plug-in connection that must be fully seated and positively latched during installation.

Official Specifications
Standard Cabinet Designation A300
Parallel-System Designation A400
Upstream Supply Reference 24 V supply G130
Monitored Internal Supply Channel 1 5 V
Monitored Internal Supply Channel 2 12 V
A300 5 V Supply Fault Message 164
A300 12 V Supply Fault Message 165
A400 5 V Supply Fault Message 212
A400 12 V Supply Fault Message 213
Upper Crowbar-Gating Link A181 to A300 by fiber-optic cable
Lower Crowbar-Gating Link A182 to A300 by fiber-optic cable
Control Connector Path A300-X1 to D02A2-X32
Handling Requirement Protectio contra descargas electrostaticas pro modulo electronicos
Fons officialis: Catalogo Siemens SIMOVERT MV DA 63 . Detalios del servitio tecnicum sequuntur le Instructiones de Maintenance Siemens SIMOVERT MV, Numero de Ordine 6SE8001-0CJ76, Edicio 07.2001.

Quaestiones Frequenter Rogatae

Ubi 6SY8102-0LA02 est installatum in un convertitore SIMOVERT MV?

Le assembly UEL occupa le position A300 in un configuration standard, dum un configuration parallelo addit un secundo assembly in A400.

Quales circuitos de alimentation debe esser verificate quando 6SY8102-0LA02 reporta un defecto de tension interne?

Verifica le alimentation superior de 24 V G130 e postea verifica le canales de 5 V e 12 V monitorate.

Quomodo debe esser montate le connector sur 6SY8102-0LA02 durante le installation?

Inserta le connector firmemente e confirma que il ha facte un click complete in su position ante de energisar le convertitore.

Quales ligamines de gatillo de crowbar interfaciat con 6SY8102-0LA02?

The upper and lower paths run from A181 and A182 to the A300 assembly through fiber-optic cables.

What handling precautions apply when replacing 6SY8102-0LA02?

Use electrostatic-discharge controls, avoid insulating materials and do not touch electronic contacts.

What isolation steps are required before removing 6SY8102-0LA02?

Disconnect the converter, secure it against reconnection, verify absence of voltage, ground and short-circuit it, and cover adjacent live parts.

What should be verified after installing 6SY8102-0LA02?

Confirm connector engagement, X1 continuity, fiber-optic routing and clearance of the related auxiliary-supply and crowbar feedback faults.

Compatibility & Ordering Notes
Before ordering 6SY8102-0LA02: confirm the installed UEL position and every signal and supply connection documented for the converter.

Compatibility Checklist for 6SY8102-0LA02

  • Concorda numerum articuli integrum 6SY8102-0LA02 et notam UEL2 in confectione praesenti.
  • Confirma utrum converter utatur solum positionem normalem A300 an etiam positionem A400 pro circuitu parallelo.
  • Verifica itinera fibrae opticae A181 et A182 et connexionem ab A300-X1 ad D02A2-X32 antequam removetur.
  • Notifica orientationem originalem connexorum et observa praecutiones contra staticam electricitatem (ESD) per totum substitutionis processum.
Hot Selling Models
3RG7011-7AB01-PF
3RT1026-1BB40 3RT1926-1ER00
4600555
ILA31.5BPKGAS
DZ73
150379
113650
DCC08 M02 PSK-TSL
3SB3901-1CF
BES000L
A02B-0120-K324
NBB1.5-F79-E2
NBB2-12GM30-E2-V1
06P3703/S35L
3RU1936-3AA01

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.