Siemens SIMOVERT MV 6SY8102-0LA02 UEL2 Electronic Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SIMOVERT MV · UEL2 ELECTRONIC MODULE

6SY8102-0LA02 SIMOVERT MV UEL2 Electronic Module

UEL2 electronic module used for monitored auxiliary supplies and crowbar-gating signal paths in SIMOVERT MV medium-voltage drive converters.

At a Glance

Brand Siemens
Model 6SY8102-0LA02
Product Type UEL2 electronic module
Core Function Monitors auxiliary supply status and transfers crowbar-gating signals
Application or Compatible Series SIMOVERT MV medium-voltage drive converters
Exact IdentificationMatch the complete article number and UEL2 assembly designation.
Supply CheckConfirm the upstream 24 V feed and both monitored internal supply channels.
Signal-Path CheckVerify module position, X1 connection and fiber-optic routing before replacement.
Product Overview

Siemens documents the UEL module as part of the SIMOVERT MV medium-voltage converter control and crowbar system. The exact product photographs identify this assembly as UEL2 with article number 6SY8102-0LA02.

In the standard configuration the UEL assembly is designated A300; a parallel converter configuration adds a second UEL at A400. The maintenance instructions identify monitored 5 V and 12 V internal supplies and fiber-optic crowbar-gating links from A181 and A182.

Ordering focus: match the complete article number, UEL2 marking, cabinet position, connector path and fiber-optic routing before replacement.

Key Functions

Auxiliary-Supply Monitoring

Monitors the internal 5 V and 12 V supply channels derived from the upstream 24 V supply.

Crowbar-Gating Signal Interface

Carries the upper and lower DC-link crowbar-gating paths through fiber-optic connections.

Fault Localization

Provides separate diagnostic fault messages for the A300 module and for the additional A400 module in parallel systems.

Serviceable Module Connection

Uses a plug-in connection that must be fully seated and positively latched during installation.

Official Specifications
Standard Cabinet Designation A300
Parallel-System Designation A400
Upstream Supply Reference 24 V supply G130
Monitored Internal Supply Channel 1 5 V
Monitored Internal Supply Channel 2 12 V
A300 5 V Supply Fault Message 164
A300 12 V Supply Fault Message 165
A400 5 V Supply Fault Message 212
A400 12 V Supply Fault Message 213
Upper Crowbar-Gating Link A181 to A300 by fiber-optic cable
Lower Crowbar-Gating Link A182 to A300 by fiber-optic cable
Control Connector Path A300-X1 to D02A2-X32
Handling Requirement Electrostatic-discharge protection for electronic modules
Official source: Siemens SIMOVERT MV DA 63 catalog. Technical service details follow Siemens SIMOVERT MV Maintenance Instructions, Order No. 6SE8001-0CJ76, Edition 07.2001.

Frequently Asked Questions

Where is 6SY8102-0LA02 installed in a SIMOVERT MV converter?

The UEL assembly occupies position A300 in a standard configuration, while a parallel configuration adds a second assembly at A400.

Which supply circuits should be checked when 6SY8102-0LA02 reports an internal-voltage fault?

Check the upstream 24 V supply G130 and then verify the monitored 5 V and 12 V channels.

How should the connector on 6SY8102-0LA02 be fitted during installation?

Seat the connector firmly and confirm that it has snapped completely into place before energizing the converter.

Which crowbar-gating links interface with 6SY8102-0LA02?

The upper and lower paths run from A181 and A182 to the A300 assembly through fiber-optic cables.

What handling precautions apply when replacing 6SY8102-0LA02?

Use electrostatic-discharge controls, avoid insulating materials and do not touch electronic contacts.

What isolation steps are required before removing 6SY8102-0LA02?

Disconnect the converter, secure it against reconnection, verify absence of voltage, ground and short-circuit it, and cover adjacent live parts.

What should be verified after installing 6SY8102-0LA02?

Confirm connector engagement, X1 continuity, fiber-optic routing and clearance of the related auxiliary-supply and crowbar feedback faults.

Compatibility & Ordering Notes
Before ordering 6SY8102-0LA02: confirm the installed UEL position and every signal and supply connection documented for the converter.

Compatibility Checklist for 6SY8102-0LA02

  • Match the complete 6SY8102-0LA02 article number and the UEL2 marking on the existing assembly.
  • Confirm whether the converter uses only the standard A300 position or also the A400 position for a parallel circuit.
  • Verify the A181 and A182 fiber-optic routes and the A300-X1 to D02A2-X32 connection before removal.
  • Record the original connector orientation and observe ESD precautions throughout the replacement.
Hot Selling Models
3RG7011-7AB01-PF
3RT1026-1BB40 3RT1926-1ER00
4600555
ILA31.5BPKGAS
DZ73
150379
113650
DCC08 M02 PSK-TSL
3SB3901-1CF
BES000L
A02B-0120-K324
NBB1.5-F79-E2
NBB2-12GM30-E2-V1
06P3703/S35L
3RU1936-3AA01