Siemens SIMATIC DP 6ES7134-0HF01-0XB0 ET 200B 4AI Modulus Analogi Ingressus
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
SIEMENS SIMATIC DP • ET 200B
6ES7134-0HF01-0XB0 ET 200B 4AI Analog Input Module
Four-channel analog input electronics for ET 200B distributed I/O, supporting selectable voltage and current measurement ranges.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7134-0HF01-0XB0 |
| Typus Producti | ET 200B analog input module |
| Functio principalis | Acquires four analog process signals |
| Series Compatible | SIMATIC DP ET 200B |
Exact Module Match
Match the full article number and the hardware release before replacing an installed ET 200B analog module.
Signal Range Selection
Set each channel group for the required voltage or current range before commissioning.
Terminal Assignment
Use the documented TB8 terminal assignment and preserve the existing channel wiring.
Product Overview
6ES7134-0HF01-0XB0 is a Siemens SIMATIC DP electronic module for the ET 200B distributed I/O system. It provides four analog input channels for voltage and current measurement.
The selectable ranges cover bipolar voltage and current signals as well as 0 to 20 mA and 4 to 20 mA process loops, with the measured values transferred as 16-bit words using the documented analog-value representation.
Key Functions
Multi-Range Analog Acquisition
The four inputs can be parameterized for ±1.25 V, ±2.5 V, ±5 V, ±10 V, ±20 mA, 0 to 20 mA or 4 to 20 mA signals.
Process-Value Encoding
The module converts the selected analog range into a defined digital value representation for the controller input area.
Diagnostics Canalium
Intervalus 4 ad 20 mA suadet aestimationem interruptae lineae, cum comportamento diagnosticorum specifico pro singulis versionibus, quod considerandum est dum fit substitutio.
Official Specifications
| Canali Analogici Input | 4 |
|---|---|
| Intervala Mensurae Tensionis | ±1,25 V, ±2,5 V, ±5 V et ±10 V |
| Intervala Mensurae Currentis | ±20 mA, 0 ad 20 mA et 4 ad 20 mA |
| Resolutio Analogica | 12 bita |
| Blocculus terminalem | TB8 |
| Representatio Digitalis | Complementum binarium, signum-et-magnitudo vel numeratio binaria, secundum intervalum configuratum |
| Intervalum Digitale Nominale | 0 ad 27648 |
| valor Digitalis 4 mA | 0 in intervallo 4–20 mA |
| valore digitale 16 mA | 20736 in intervallo 4–20 mA |
| valore digitale 20 mA | 27648 in intervallo 4–20 mA |
| Sovraccarico superiore | 27649–32511 |
| Codice di overflow | 32767 (7FFFH) |
| Codice di underflow | -32768 (8000H) |
| Wire-Break Evaluation | Available for the 4 to 20 mA measuring range |
Quaestiones Frequenter Rogatae
Can 6ES7134-0HF01-0XB0 measure both voltage and current signals?
Yes, the module supports selectable bipolar voltage ranges and current ranges including 0 to 20 mA and 4 to 20 mA.
Which terminal block should I use with 6ES7134-0HF01-0XB0?
Use the TB8 terminal block and follow the channel assignment for the configured input ranges.
How is a 4 to 20 mA signal scaled by 6ES7134-0HF01-0XB0?
The rated range maps 4 mA to 0 and 20 mA to 27648 in the controller input word.
Does 6ES7134-0HF01-0XB0 detect a broken 4 to 20 mA loop?
The module provides wire-break evaluation in the 4 to 20 mA range, with diagnostic behavior depending on the hardware release.
What should I preserve when replacing 6ES7134-0HF01-0XB0?
Preserve the TB8 wiring, the channel-group range settings and the data-format configuration used by the PLC program.
Can 6ES7134-0HF01-0XB0 be configured below a Y-Link?
This analog module is excluded from the ET 200B components that can be configured directly on the subordinate DP master system of a Y-Link.
Which data formats can 6ES7134-0HF01-0XB0 use for bipolar values?
Bipolar values can be represented in two’s complement, sign-and-magnitude or binary form according to the selected configuration.
Compatibility & Ordering Notes
Constitutiones Consonantiae
- Confirmare omnes quattuor canales intervalla mensurae adversus parametrizationem praesentem.
- Verificare logicam PLC pro scalatione adversus representationem valorem analogicum configuratam.
- Pro circuitu 4 ad 20 mA, considerare comportamentum diagnosticum interrupti fili dependentem a versione edita.
- Non collocare hoc modulum in systemate DP subordinato configurationis Y-Link quae ipsum excludit.