SIEMENS SIMATIC DP • ET 200B
6ES7134-0HF01-0XB0 ET 200B 4AI Analog Input Module
Four-channel analog input electronics for ET 200B distributed I/O, supporting selectable voltage and current measurement ranges.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7134-0HF01-0XB0 |
| Product Type | ET 200B analog input module |
| Core Function | Acquires four analog process signals |
| Compatible Series | SIMATIC DP ET 200B |
Exact Module Match
Match the full article number and the hardware release before replacing an installed ET 200B analog module.
Signal Range Selection
Set each channel group for the required voltage or current range before commissioning.
Terminal Assignment
Use the documented TB8 terminal assignment and preserve the existing channel wiring.
Product Overview
6ES7134-0HF01-0XB0 is a Siemens SIMATIC DP electronic module for the ET 200B distributed I/O system. It provides four analog input channels for voltage and current measurement.
The selectable ranges cover bipolar voltage and current signals as well as 0 to 20 mA and 4 to 20 mA process loops, with the measured values transferred as 16-bit words using the documented analog-value representation.
Key Functions
Multi-Range Analog Acquisition
The four inputs can be parameterized for ±1.25 V, ±2.5 V, ±5 V, ±10 V, ±20 mA, 0 to 20 mA or 4 to 20 mA signals.
Process-Value Encoding
The module converts the selected analog range into a defined digital value representation for the controller input area.
Channel Diagnostics
The 4 to 20 mA range supports wire-break evaluation, with release-specific diagnostic behavior that should be considered during replacement.
Official Specifications
| Analog Input Channels | 4 |
|---|---|
| Voltage Measuring Ranges | ±1.25 V, ±2.5 V, ±5 V and ±10 V |
| Current Measuring Ranges | ±20 mA, 0 to 20 mA and 4 to 20 mA |
| Analog Resolution | 12 bits |
| Terminal Block | TB8 |
| Digital Representation | Two’s complement, sign-and-magnitude or binary, depending on the configured range |
| Rated Digital Range | 0 to 27648 |
| 4 mA Digital Value | 0 in the 4 to 20 mA range |
| 16 mA Digital Value | 20736 in the 4 to 20 mA range |
| 20 mA Digital Value | 27648 in the 4 to 20 mA range |
| Upper Overrange | 27649 to 32511 |
| Overflow Code | 32767 (7FFFH) |
| Underflow Code | -32768 (8000H) |
| Wire-Break Evaluation | Available for the 4 to 20 mA measuring range |
Frequently Asked Questions
Can 6ES7134-0HF01-0XB0 measure both voltage and current signals?
Yes, the module supports selectable bipolar voltage ranges and current ranges including 0 to 20 mA and 4 to 20 mA.
Which terminal block should I use with 6ES7134-0HF01-0XB0?
Use the TB8 terminal block and follow the channel assignment for the configured input ranges.
How is a 4 to 20 mA signal scaled by 6ES7134-0HF01-0XB0?
The rated range maps 4 mA to 0 and 20 mA to 27648 in the controller input word.
Does 6ES7134-0HF01-0XB0 detect a broken 4 to 20 mA loop?
The module provides wire-break evaluation in the 4 to 20 mA range, with diagnostic behavior depending on the hardware release.
What should I preserve when replacing 6ES7134-0HF01-0XB0?
Preserve the TB8 wiring, the channel-group range settings and the data-format configuration used by the PLC program.
Can 6ES7134-0HF01-0XB0 be configured below a Y-Link?
This analog module is excluded from the ET 200B components that can be configured directly on the subordinate DP master system of a Y-Link.
Which data formats can 6ES7134-0HF01-0XB0 use for bipolar values?
Bipolar values can be represented in two’s complement, sign-and-magnitude or binary form according to the selected configuration.
Compatibility & Ordering Notes
Compatibility Checks
- Confirm all four channel measuring ranges against the existing parameterization.
- Check the PLC scaling logic against the configured analog-value representation.
- For a 4 to 20 mA loop, account for the release-dependent wire-break diagnostic behavior.
- Do not place this module in the subordinate DP system of a Y-Link configuration that excludes it.