Siemens RWD44U Universal Staged HVAC and Refrigeration Controller
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use a 24 V AC SELV supply and the specified safety-isolating transformer arrangement.
- Disconnect controlled outputs before changing the application selection.
- Allow at least 8 mm clearance between terminals and the panel or enclosure.
- Provide the selected DIN-rail, wall or ARG62.21 enclosure mounting arrangement.
RWD44U Universal Staged HVAC and Refrigeration Controller
A standalone controller with universal sensor inputs and four relay outputs for heating, cooling and one-, two- or three-stage compressor applications.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | RWD44U |
| Typus Producti | Standalone temperature controller |
| Functio principalis | Staged heating and cooling regulation |
| Applicatio | HVAC, refrigeratio et machinae thermicae |
Entratas universal de sensor
X1 et X2 accipiunt signa sensoria Siemens Ni 1000, Pt 1000 aut activa 0–10 V DC.
Quattuor relais extritus
Q1 ad Q4 praebent regulatonem binae positionis pro applicatione electa.
Gradatio compressoris
Applicationes praedefinitae sufficiunt ad usum usque ad tres gradus compressoris et valvulam inversivam.
Product Overview
RWD44U regulat apparatus calefaciendos, frigefaciendos et refrigerantes per quattuor exirens relais on/off. Applicationes praedefinitae eius comprehendunt duas gradus calefactionis et duas gradus frigefactionis aut usque ad tres gradus compressoris cum valvula inversiva pro operatione machinae thermicae.
Ingressus X1 praebet mensuram temperaturae principalem, dum X2 praebere potest sensum auxiliarem, punctum destinatum remotum, mediotionem aut alias functiones electas. Ingressus D1 separatus sufficit ad functiones ut commutatio diurna/nocturna, status stand-by et tractatio allarum.
Key Functions
Configura regulatonem apparatus gradatam
Applicationes 10–19 praebent gradus calefaciendi et refrigescendi, dum applicationes 20–39 constituunt gradus compressoris et valvulam inversivam.
Adaptare functiones sensus et auxiliares
Canalia universalia ingressus sustinent signa Ni 1000, Pt 1000 et activa 0–10 V DC; X2 etiam sustinet regulam resistentiae remotae.
Coordinare moras commutationis
Tempora minima activa/inactiva et morae inter gradus aut inter calefactionem/refrigerationem sunt adiustabilia ab 0 usque ad 4 096 secundas.
Official Specifications
| Alimentatio contrullatoris | 24 V AC, SELV |
|---|---|
| Canalia universalia ingressus | 2, designata X1 et X2 |
| Signa sensorum acceptata | Siemens Ni 1000, Pt 1000 et 0–10 V DC |
| Ni 1000 sensus intervallum | −50 ad +150 °C |
| Pt 1000 sensus intervallum | −20 ad +180 °C |
| Activus ingressus scalatio limites | −100 ad 2 400 pro 0–10 V DC ingressu intervallo |
| Remotus consignatio ingressus ad X2 | 0–10 V DC aut 0–1 000 Ω |
| Ingressus digitalis | 1, designatus D1 |
| Egressus Regulatorii | 4 bina positio relais exire, Q1–Q4 |
| Relay Switching Voltage | 24–240 V AC |
| Praestationes contactuum relais | 5 A resistive; 5 FLA; 30 LRA; 1/2 HP |
| Switching differential range | 0.1–50 K |
| Switching timing ranges | 0–4 096 s for minimum on/off, interstage and heating/cooling changeover delays |
| Sensor calibration offset | −5 to +5 K for Ni and Pt sensor inputs |
| PC tool connection | 9-pin TOOL communication connector |
| Controller Dimensions | 130 × 106 × 56.5 mm (L × A × P) |
Quaestiones Frequenter Rogatae
È possibile collegare direttamente i terminali di alimentazione del RWD44U a 230 V CA?
L’alimentazione del regolatore richiede 24 V CA SELV, non la tensione di rete.
Il RWD44U può comandare una pompa di calore con tre stadi di compressore?
Le applicazioni preconfigurate per pompe di calore supportano fino a tre stadi di compressore e una valvola inversa.
Quali sensori di temperatura passivi è possibile collegare al RWD44U?
Gli ingressi universali supportano i sensori di temperatura Siemens Ni 1000 e Pt 1000.
È possibile ridefinire l’intervallo di misura del sensore Ni 1000 sul RWD44U come per un ingresso attivo?
L’intervallo del sensore Ni 1000 è fisso da −50 a +150 °C, mentre gli ingressi attivi 0–10 V CC consentono una scala definita dall’utente.
Can RWD44U average two temperature measurements?
The auxiliary-function selection includes averaging of the X1 and X2 sensor inputs.
Is a PC required for the initial setup of RWD44U?
The controller supports local parameter setup, while the PC software tool is optional.
How can I keep RWD44U from switching a compressor on and off too quickly?
Set the required minimum on and minimum off times within their 0–4,096 second adjustment ranges.