  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus
APOGEE Point Pickup Module

PPM-1U32.PPF APOGEE P1 FLN Point Pickup Module

An Asia-Pacific PPM with fixed terminals, configurable thermistor or contact sensing, dry-contact inputs and two relay outputs.

Ad Primum Aspectum

Nota Siemens
Modellum PPM-1U32.PPF
Typus Producti Building-control I/O expansion module
Functio principalis Expanding field-panel input and output points
Applicatio APOGEE panels with P1 FLN or expansion-bus capability

Configurable sensing point

A slide switch selects a 10 kΩ Type II NTC thermistor or a dry-contact digital input.

Expansion of digital points

Fixed digital inputs and normally open relay outputs extend field-panel connections.

Automatic recovery of communication

The module resumes network communication after a power interruption without operator intervention.

Product Overview

PPM-1U32.PPF adds primarily digital field points to a compatible APOGEE panel.

The P1 FLN or expansion-bus module combines one switch-configurable analog/digital input, three fixed digital inputs, and two relay outputs in a junction-box-mountable housing.

Focus ordinandi: Match the P1-capable field panel, 24 V AC power source, sensor mode, relay load, and fixed-terminal PPF version.
Key Functions

Configurable sensing point

A slide switch selects a 10 kΩ Type II NTC thermistor or a dry-contact digital input.

Expansion of digital points

Fixed digital inputs and normally open relay outputs extend field-panel connections.

Automatic recovery of communication

The module resumes network communication after a power interruption without operator intervention.

Official Specifications
Tensio et frequencia suppeditatae 19.2–28.8 V AC; 50 or 60 Hz
Consumptio potentiae 4 VA
I/O allocation 1 configurable AI/DI, 3 fixed digital inputs, and 2 digital outputs
Typus sensoris analogici thermistor NTC typi II, 10 kΩ
Functiones Ingressus Digitalis Contactus siccus aut LPACI
Praestationes contactuum relais Forma A, normaliter apertus, communis communis; 24–250 V AC, 3 A resistivus aut 2 A ad usum generalem
Celeritates Communicationis 4800 per defaltum; detegitur automatio 9600, 19200, 38400, 57600 aut 115200 bit/s
Selectio adressae 8-bit interruptor DIP
Interfacs communicandi localis Nullus
Accuratio monitoris temperaturae ±0.25 °F inter 55–95 °F (13–35 °C)
Limen defectus temperaturae Punctum monstrat FAILED sub 20 °F (−6.7 °C) aut supra 120 °F (48.9 °C)
Ambiens Operativum 0–50 °C; 5–95% RH, non-condensing
Ambiens depositi −40 usque ad +70 °C
Terminal version Fixed terminal blocks
Dimensiones et Pondera 114.3 × 114.4 × 34.5 mm; 0.5 lb
Quaestiones Frequenter Rogatae

Can I change the configurable input of PPM-1U32.PPF from a contact to a temperature sensor?

A slide switch selects dry-contact input or a 10 kΩ Type II NTC thermistor.

Which field-panel network is used by PPM-1U32.PPF?

The module communicates on a P1 FLN or a compatible field-panel expansion bus.

Will PPM-1U32.PPF rejoin the network automatically after a power interruption?

Modulus recuperat et restituit communicationem sine interventu operatoris.

Num possum usus esse ordinario suppeditatore CC pro specificata potestate intrante PPM-1U32.PPF?

Specificata intratio est 19,2–28,8 V AC ad 50 vel 60 Hz.

Cur punctum temperaturae in PPM-1U32.PPF monstrat FAILED ad humilem temperaturam exterius?

Punctum monstrat FAILED cum eius temperatio cadit infra 20 °F, aut fere −6,7 °C.

Quod accessorium necessarium est ad montandum PPM-1U32.PPF super railem DIN?

Utere separatim praebito catena montandi PPM-DINKIT.

Quomodo PPM-1U32.PPF separavit connexionem scatulae alti voltatis et scatulae bassi voltatis?

Barriera integrata amovibilis separat areas connexionum.

Compatibility & Ordering Notes
Antequam ordines PPM-1U32.PPF: Match the P1-capable field panel, 24 V AC power source, sensor mode, relay load, and fixed-terminal PPF version.

Antequam Installatio

  • Utere compatibilibus P1 FLN aut campo tabulae expansionis et assigna numerum moduli.
  • Praebere specificatum suppetitum AC et ponere interruptorem cursus sensoris pro input coniuncto.
  • Tenere onera rellay intra valorem resistivum aut usus generalis et servare barriera wirorum.
  • Eligere dispositionem montis cistulae iunctionis aut kitum DIN-rail separatim ordinatum.
Hot Selling Models
IW5064 IW-3008-BPKG/AS-610-TPS
6ES5375-8LA12
SK968 EK96VD8
6ES5950-1AB61
6ES7368-3BB01-0AA0
K16-235
5SU1356-6KK06
5SU1354-7KK06
LC1D12BD 035371
7NG3020-3JN40
K1.K4506.50
32/80-AG
KL3306
M08EH-NSC15B-S04G BES01PC
SDE5-D10-C-Q6E-P-M8-W5-X

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.