Siemens SINAMICS · Power Stack Adapter
A5E00468282 Power Stack Adapter PSA2
Power-stack interface adapter prepared for SINAMICS GM150 and SM150 converter safety arrangements using the user-specified Siemens reference 6SL3995-6AX00-0BA0.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | A5E00468282 |
| Typus Producti | Power Stack Adapter PSA2 |
| Functio principalis | Interfaces the converter control and power-stack safety signal path |
| Series Compatible | SINAMICS GM150 and SM150 converter cabinets |
Identificatio exacta.
Match A5E00468282 and the PSA2 reference order number before replacing the installed adapter.
Safety Interface
Preserve both independent low-active switch-off paths used by the installed converter safety circuit.
Converter Check
Confirm the SINAMICS cabinet type, option K80 arrangement and external safety-device wiring.
Product Overview
A5E00468282 is listed here as a Siemens SINAMICS Power Stack Adapter PSA2 using the technical parameter basis requested for 6SL3995-6AX00-0BA0.
Within SINAMICS GM150 and SM150 converter cabinets, the Power Stack Adapter participates in the Safe Torque Off signal chain and uses two independent failsafe low-active switch-off paths.
Key Functions
Power-Stack Signal Interface
The adapter connects the converter-control safety path to the power stack within the approved SINAMICS cabinet arrangement.
Dual Failsafe Switch-Off Paths
Two independent low-active channels are used so a wire break or component failure drives the safety circuit toward the safe state.
Safe Torque Off Preparation
Cum SIRIUS 3SK1 securitatis relais, adapter praeparat optionem K80 STO ad consummationem per externum emergentiae-stop dispositivum aut securitatis PLC.
Official Specifications
| Numerus Ordinis Referentiae | 6SL3995-6AX00-0BA0 |
|---|---|
| Contextus Functionis Securitatis | Secura Torque Off cum optione K80 |
| Architectura Interruptoris | Duae independens vias signali secures |
| Logica Interruptoris | Activa infima in utrisque viis securitatis |
| Categoria Securitatis ISO | Categoria 3 |
| Gradus operationis | PL e |
| Nivelis Integritātis Securitātis | SIL 3 |
| Functional-Safety Standard | EN ISO 13849-1:2015 |
| Electrical-Safety Standard | IEC 61508-5-1:2010 |
| Unexpected-Start Standard | EN 60204-1:2006/A1:2009, Sectio 5.4 |
| Companion Safety Relay | SIRIUS 3SK1 |
| Torque-Energy Response | Safety-related pulse cancellation interrupts torque-producing energy |
| Motor Electrical Isolation | Motor Module and motor remain electrically connected |
| K80 Altitude Threshold | Project-specific inquiry required above 2000 m |
Quaestiones Frequenter Rogatae
Can A5E00468282 be used in the STO circuit of a SINAMICS GM150 or SM150 converter?
Yes, the adapter forms part of the option K80 safety arrangement when combined with the specified safety relay and external safety device.
Which safety ratings apply to an A5E00468282 installation?
The relevant arrangement is certified to Category 3, Performance Level e and Safety Integrity Level 3.
Does A5E00468282 electrically isolate the motor when Safe Torque Off is active?
No, Safe Torque Off interrupts torque-producing energy without galvanically disconnecting the Motor Module from the motor.
How should the safety channels of A5E00468282 be wired?
Keep the two switch-off paths independent and low-active so an interrupted wire or failed component drives the system to the safe state.
Which external device completes the A5E00468282 safety function?
Use the approved SIRIUS 3SK1 relay with a suitable emergency-stop device or safety PLC for the configured machine circuit.
Can A5E00468282 be installed above 2000 metres?
An installation above 2000 m requires a project-specific Siemens inquiry before option K80 is applied.
What should be checked before replacing A5E00468282?
Match the adapter reference, converter MLFB and serial number, cabinet option, connector assignment and both safety-channel circuits before energizing the drive.
Compatibility & Ordering Notes
Index Compatibilitatis
- Confirmare converterem installatum ad configurationem armariorum SINAMICS GM150 vel SM150 pertinentem.
- Servare independentiam et comportamentum activitatis infimae utriusque viae interrumpendi tutelares.
- Verificare relais SIRIUS 3SK1 et circuitum externum emergentis arrestus vel PLC tutelaris antequam in operationem ducatur.
- Disponere examen speciale pro projecto antequam optio K80 adhibeatur supra altitudinem installationis 2000 m.