Siemens SINAMICS A5E00468282 Power Stack Adapter PSA2

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SINAMICS · POWER STACK ADAPTER

A5E00468282 Power Stack Adapter PSA2

Power-stack interface adapter prepared for SINAMICS GM150 and SM150 converter safety arrangements using the user-specified Siemens reference 6SL3995-6AX00-0BA0.

At a Glance

Brand Siemens
Model A5E00468282
Product Type Power Stack Adapter PSA2
Core Function Interfaces the converter control and power-stack safety signal path
Compatible Series SINAMICS GM150 and SM150 converter cabinets

Exact Identification

Match A5E00468282 and the PSA2 reference order number before replacing the installed adapter.

Safety Interface

Preserve both independent low-active switch-off paths used by the installed converter safety circuit.

Converter Check

Confirm the SINAMICS cabinet type, option K80 arrangement and external safety-device wiring.

Product Overview

A5E00468282 is listed here as a Siemens SINAMICS Power Stack Adapter PSA2 using the technical parameter basis requested for 6SL3995-6AX00-0BA0.

Within SINAMICS GM150 and SM150 converter cabinets, the Power Stack Adapter participates in the Safe Torque Off signal chain and uses two independent failsafe low-active switch-off paths.

Ordering focus: match A5E00468282 with reference 6SL3995-6AX00-0BA0, then confirm the converter MLFB, serial number, cabinet option K80 and safety-channel connector arrangement.
Key Functions

Power-Stack Signal Interface

The adapter connects the converter-control safety path to the power stack within the approved SINAMICS cabinet arrangement.

Dual Failsafe Switch-Off Paths

Two independent low-active channels are used so a wire break or component failure drives the safety circuit toward the safe state.

Safe Torque Off Preparation

Together with a SIRIUS 3SK1 safety relay, the adapter prepares the option K80 STO function for completion by an external emergency-stop device or safety PLC.

Official Specifications
Reference Order Number 6SL3995-6AX00-0BA0
Safety Function Context Safe Torque Off with option K80
Switch-Off Architecture Two independent failsafe signal paths
Switch-Off Logic Low-active on both safety paths
ISO Safety Category Category 3
Performance Level PL e
Safety Integrity Level SIL 3
Functional-Safety Standard EN ISO 13849-1:2015
Electrical-Safety Standard IEC 61508-5-1:2010
Unexpected-Start Standard EN 60204-1:2006/A1:2009, Section 5.4
Companion Safety Relay SIRIUS 3SK1
Torque-Energy Response Safety-related pulse cancellation interrupts torque-producing energy
Motor Electrical Isolation Motor Module and motor remain electrically connected
K80 Altitude Threshold Project-specific inquiry required above 2000 m
Frequently Asked Questions

Can A5E00468282 be used in the STO circuit of a SINAMICS GM150 or SM150 converter?

Yes, the adapter forms part of the option K80 safety arrangement when combined with the specified safety relay and external safety device.

Which safety ratings apply to an A5E00468282 installation?

The relevant arrangement is certified to Category 3, Performance Level e and Safety Integrity Level 3.

Does A5E00468282 electrically isolate the motor when Safe Torque Off is active?

No, Safe Torque Off interrupts torque-producing energy without galvanically disconnecting the Motor Module from the motor.

How should the safety channels of A5E00468282 be wired?

Keep the two switch-off paths independent and low-active so an interrupted wire or failed component drives the system to the safe state.

Which external device completes the A5E00468282 safety function?

Use the approved SIRIUS 3SK1 relay with a suitable emergency-stop device or safety PLC for the configured machine circuit.

Can A5E00468282 be installed above 2000 metres?

An installation above 2000 m requires a project-specific Siemens inquiry before option K80 is applied.

What should be checked before replacing A5E00468282?

Match the adapter reference, converter MLFB and serial number, cabinet option, connector assignment and both safety-channel circuits before energizing the drive.

Compatibility & Ordering Notes
Before ordering A5E00468282: match the complete A5E number and 6SL3995-6AX00-0BA0 reference, and provide the converter MLFB, serial number and option K80 circuit details.

Compatibility Checklist

  • Confirm the installed converter belongs to the applicable SINAMICS GM150 or SM150 cabinet configuration.
  • Preserve the independence and low-active behavior of both safety switch-off paths.
  • Verify the SIRIUS 3SK1 relay and external emergency-stop or safety-PLC circuit before commissioning.
  • Arrange a project-specific review before using option K80 above 2000 m installation altitude.
Hot Selling Models
VAM40V1/0R1/8EN
3842 542 555
VMPA1-DP 533359
631.153.000.923.000 50086390
GV2-M06
ABB S202
5-HF 12DC-ST
SAC-5P-MINMS/0.6-441/MINFS
8340-GIII-NIF4-A4HIII
3VU1300-1MD00
7999-88001-2330150
7000-12261-6331000
1.5-24/5 85 657
PT78704
VQC1101N-51

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.