Siemens 6SL3244-0BA20-1BA0 SINAMICS G120 CU240S Control Unit
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Custodi CU240S communicationis variantem congruentem cum installato automation interface.
- Apta motoris data et electam control methodum dum commissionaris.
- Constitue analog-input DIP switches et parameters pro signis voltaticis vel currentibus.
- Serva backup parameter set antequam control unit intermutas.
SIEMENS SINAMICS G120 CU240S
6SL3244-0BA20-1BA0 SINAMICS G120 CU240S Control Unit
Control a modular G120 inverter through local terminals or USS on RS485, with analog setpoints, motor-temperature monitoring and an encoder interface.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3244-0BA20-1BA0 |
| Typus Producti | Motor drive control unit |
| Functio principalis | Regulate speed with optional encoder feedback |
| Applicatio | Modular SINAMICS G120 drives |
Terminal and serial commands
Local digital signals and USS on RS485 provide command and setpoint paths.
Encoder-capable control
The standard CU240S supports closed-loop control with encoder feedback.
Parameter transfer tools
BOP, STARTER and an MMC support commissioning and backup workflows.
Product Overview
6SL3244-0BA20-1BA0 is the standard CU240S control unit used with a separate power module in the SINAMICS G120 modular drive system. It combines programmable terminal I/O, serial communication and an encoder connection for motor-control applications.
The control functions include V/f and vector methods, programmable fixed frequencies and skip frequencies, while the MMC provides a portable store for parameter sets during series commissioning and replacement.
Key Functions
Applicatio controlus in circuitu aperto aut cum retroactione
Controlus V/f et controlus vectorialis praebent optiones operationis pro velocitate et momento motoris, inter quas etiam controlus cum retroactione encoderis.
Selectio imperatorum ab terminalibus aut ab fontibus USS
Ingressus programmabiles et canales analogici suffragantur signa localia machinae, dum interfacies RS485 portat imperata USS et data processus.
Reusus copiarum parametrorum iam commissionatarum
MMC servat usque ad 100 copias parametrorum et suffragat transfertionem ad aliam unitatem controlus pro commissionibus repetitis.
Official Specifications
| Control Supply | 24 V DC ab modulo potentiae aut ab alimentatione externa |
|---|---|
| Intervalum Operationis Alimentationis Externae | 20,4 ad 28,8 V DC; 0,5 A |
| Ingressus Digitalis Programmabilis | 9 ingressus PNP isolati; infimus sub 5 V, supremus super 10 V |
| Maxima Tensio Ingressus Digitalis | 30 V |
| Canali Analogici Input | 2 ingressus programmabiles, etiam configurabiles ut ingressus digitalis addititionales |
| Intervalla Ingressus Analogi | AI0: 0 ad 10 V, −10 ad +10 V aut 0 ad 20 mA; AI1: 0 ad 10 V aut 0 ad 20 mA |
| Egressus Relais Programmabiles | 3; usque ad 30 V DC et 0.5 A cum oneribus resistivis |
| Limites Egressus Analogici | AO0: 0 ad 10 V aut 0 ad 20 mA; AO1: 0 ad 20 mA |
| Communicatio serialis | USS per RS485 |
| Intervallo Frequentiae Egressus V/f | 0 usque ad 650 Hz |
| Intervalum frequentialis outputus vector-control | 0 ad 200 Hz |
| Praesetationes frequentialis | 16 frequentialia fixa programmabilia et 4 frequentialia saltanda |
| Resolutio puncti destinati | 0.01 Hz digitalis et serialis; analogica 10-bit |
| Storatio parametrorum MMC | Usque ad 100 series parametrorum |
| Dimensiones | 73 × 178 × 55 mm (latus × altitudo × profunditas) |
| Massa approximata | 0.52 kg |
Quaestiones Frequenter Rogatae
Quod protocolum seriale uti possum ad imperandum 6SL3244-0BA20-1BA0 per terminales RS485?
Unitas controlis standardis supportat communicationem USS per RS485.
Does 6SL3244-0BA20-1BA0 support Encoder-capable control for mobile equipment?
Yes, the standard CU240S supports speed and torque control with encoder feedback.
How can I reproduce the settings of 6SL3244-0BA20-1BA0 on another drive?
Store the commissioned parameter set on an MMC and transfer it to the replacement control unit.
Must an MMC remain installed for 6SL3244-0BA20-1BA0 to run?
No, the inverter can operate with or without an MMC fitted.
Can I enter a bipolar analog setpoint on 6SL3244-0BA20-1BA0?
Analog input AI0 accepts a −10 to +10 V signal in addition to its unipolar voltage and current ranges.
How can I avoid a resonance speed when configuring 6SL3244-0BA20-1BA0?
Use the four programmable skip frequencies to exclude the relevant operating-frequency bands.
Quid uti debes ad 6SL3244-0BA20-1BA0 ex computatro commissionandam?
Usus STARTER cum PC connection kit per option port.