Siemens • SINAMICS S120 Booksize Drive System
6SL3120-2TE13-0AD0 SINAMICS S120 Double Motor Module 2 x 3 A
The SINAMICS S120 Double Motor Module is a booksize D-type power module with internal air cooling, two 3 A motor outputs and DRIVE-CLiQ integration for compact two-axis drive configurations.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3120-2TE13-0AD0 |
| Typus Producti | Modulus motoris D-formae libri duorum axis |
| Functio principalis | Supplet et regit duos axes motoris ex communi nexu DC |
| Applicatio vel series compatibiles | Systemata SINAMICS S120 libri formae utentia DRIVE-CLiQ et functiones integratas tutelae amplificatas |
Identificatio exacta.
Confer numerum articuli 6SL3120-2TE13-0AD0 littera per litteram et confirma designationem integram moduli motoris duplicis SINAMICS S120: 2 × 3 A.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The SINAMICS S120 Double Motor Module is a booksize D-type power module with internal air cooling, two 3 A motor outputs and DRIVE-CLiQ integration for compact two-axis drive configurations.
Unus modulus supplet duos axes motoris independenter regulatos ex communi nexu DC SINAMICS. Habitaculum angustum formae D connectitur ad ordines libri formae SINAMICS S120, nexum DC et dispositiones 24 V compatibiles. Modulus supportat functiones integratas tutelae amplificatas, si utatur cum hardware controlis requisito et projecto tutelae configurato.
Key Functions
Duae effusiones motoris
Unus modulus supplet duos axes motoris independenter regulatos ex communi nexu DC SINAMICS.
Integratio systematis libri formae
The narrow D-type housing connects into compatible SINAMICS S120 booksize line, DC-link and 24 V arrangements.
Integrated Safety Support
The module supports extended Safety Integrated functions when used with the required control hardware and commissioned safety project.
Official Specifications
| Tensio Interfascis Directa | 510 usque ad 720 V CC |
|---|---|
| Currentis Output Aestimatus | 2 × 3 A |
| Base-Load Current | 2 × 2.6 A |
| S6 Intermittent Current at 40% | 2 × 4 A |
| Currentia maxima emissa | 2 × 9 A |
| Tensio Egressus | 0 to 0.717 × DC-link voltage; up to 480 V at 670 V DC |
| Frequens output | 0 to 550 Hz |
| Currentus Linkus DC | 7,2 A |
| Capacitas Linkus DC | 220 µF |
| Nivelus Tripus Supervoltatus | 820 V DC ±2% |
| Nivelus Tripus Subvoltatus | 380 V DC ±2% |
| Alimentatio Electronica | 24 V DC; 20.4 to 28.8 V |
| Currentus Electronici ad 24 V | 0.9 A |
| Maximum Shielded Motor Cable | 50 m |
| Maximum Unshielded Motor Cable | 75 m |
| Dimensiones | 50 × 380 × 270 mm |
| Ponderis netum | 4.7 Kg |
| Gradus praesidium | IP20; UL typus apertus |
Quaestiones Frequenter Rogatae
Quae motores coniungi possunt ad 6SL3120-2TE13-0AD0?
Utere duobus motoribus quorum voltatio, currentus continuus, currentus pico, requisita feedback et frenandi congruunt cum configuratione ingeniosa SINAMICS.
Can both axes on 6SL3120-2TE13-0AD0 be commissioned independently?
Yes; each motor output has its own drive object and must be parameterized, tuned and tested separately.
What DC-link conditions are required for 6SL3120-2TE13-0AD0?
Connect it only within the approved booksize DC-link arrangement and keep the operating voltage inside the specified range.
How should cooling clearance be planned for 6SL3120-2TE13-0AD0?
Maintain the required airflow path and at least 80 mm of unobstructed clearance above and below the module.
Which safety checks apply when replacing 6SL3120-2TE13-0AD0?
Validate the configured safety functions, shutdown paths, motor assignments and acceptance-test results before production use.
What must be recorded before removing 6SL3120-2TE13-0AD0?
Capture both axis parameters, motor data, encoder assignments, DRIVE-CLiQ topology, cable routing and fault history.
Quid verificandum est post installationem 6SL3120-2TE13-0AD0?
Verificare polaritatem DC-link, contactum 24 V bus, ambas fases motoris, canales retroactionis, directionem axis, limites currentis et operationem sine defectu.
Compatibility & Ordering Notes
Index Compatibilitatis
- Utere tantum intra compatibilem SINAMICS S120 booksize DC-link systemam.
- Adaptare utrumque motorem, dispositiva retroactionis et requisita currentis separatim.
- Restituere approbatam configurationem axis et Safety Integrated ante operationem.