Siemens SINAMICS 600 V DC 4000 µF Modulus Capacitoris 6SL3100-1CE14-0AA0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens • SINAMICS S120
6SL3100-1CE14-0AA0 SINAMICS 600 V DC 4000 µF Capacitor Module
The Siemens SINAMICS capacitor module is rated for a 600 V DC input and provides 4000 µF of DC-link capacitance for the matched drive configuration.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3100-1CE14-0AA0 |
| Typus Producti | DC-link capacitor module |
| Functio principalis | Adds 4000 µF of capacitance to a 600 V DC SINAMICS DC link |
| Applicatio vel series compatibiles | SINAMICS drive systems requiring the specified capacitor-module rating |
Identificatio exacta.
Match 6SL3100-1CE14-0AA0 character by character and confirm the complete SINAMICS 600 V DC 4000 µF Capacitor Module designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The Siemens SINAMICS capacitor module is rated for a 600 V DC input and provides 4000 µF of DC-link capacitance for the matched drive configuration.
The module is identified for a 600 V DC input in the matched SINAMICS drive system. Its 4000 µF capacitance supports the configured DC-link energy requirement. Mechanical arrangement, DC-link connection and discharge safety must match the engineered drive lineup.
Key Functions
Defined DC-Link Rating
The module is identified for a 600 V DC input in the matched SINAMICS drive system.
Additional Energy Storage
Its 4000 µF capacitance supports the configured DC-link energy requirement.
System-Specific Installation
Mechanical arrangement, DC-link connection and discharge safety must match the engineered drive lineup.
Official Specifications
| Modus refrigerationis | Refrigeratio Interna Aeris |
|---|---|
| 24 V DC Busbar Current Capacity | 20 A |
| Capacitas currentis in barra DC-link | 100 A |
| Conexiones del enlace CC | 2 connections via integrated DC-link busbars |
| Coniunctiones terrae protectoriae | 2 |
| Protective-Earth Terminal | M5 Vitis |
| Latitudo Moduli | 100 mm |
| Altitudo moduli | 380 mm |
| Profunditas cum spatio suppeditato | 270 mm |
| Pondus Approximatum | 7,2 kg |
| Certificate of suitability | cULus |
| Principium operationis | Operatio Sui Iuris |
| Operatio Parallelis | Plures moduli capacitatis parallele operari possunt |
| Spatium suppeditatum | Inclusa |
Quaestiones Frequenter Rogatae
Quae tensio DC-link ad 6SL3100-1CE14-0AA0 conformare debet?
Modulum tantum cum specificata tensine DC 600 V utere.
Quantam capacitatem 6SL3100-1CE14-0AA0 addit?
Modulus 4000 µF capacitatis praebet.
Num 6SL3100-1CE14-0AA0 in quodlibet armarium converteris inseri potest?
Non; configuratio mechanica et electrica systemati SINAMICS ingenio facto conformare debet.
Quid debet isolari antequam 6SL3100-1CE14-0AA0 substituitur?
Isolanda sunt omnes fontes energiae; exspecta ut catena DC descaricetur et proba tensionem esse zero.
Quid annotare debes antequam 6SL3100-1CE14-0AA0 removetur?
Annota positionem installationis, dispositionem catenarum busbar, terram, conectorum et modulorum adiacentium.
Quomodo 6SL3100-1CE14-0AA0 tractanda est dum installatur?
Utere praescriptis praecutionibus pro levatione et contra staticam electricam, et protege omnes terminales a contaminatione.
Quid inspiciendum est post installationem 6SL3100-1CE14-0AA0?
Verifica firmitatem, terram, polaritatem catenae DC, intervalla, tecta et ordinem initiationis impulsum approbatum.
Compatibility & Ordering Notes
Index Compatibilitatis
- Accurate concordare debet valor condensatoris et tensio catenae DC.
- Use only the approved SINAMICS mechanical and electrical arrangement.
- Prove the DC link is discharged before any service work.