- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens • SINAMICS S120
6SL3040-1LA01-0AA0 SINAMICS S120 CU310-2 PN Control Unit
CU310-2 PN est unitas controlis SINAMICS S120 ad applicationes impulsum unius axis habens interfaciem PROFINET integratam, et sine carta CompactFlash suppeditatur.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3040-1LA01-0AA0 |
| Typus Producti | Unitas controlis impulsum unius axis |
| Functio principalis | Executat functiones controlis impulsum unius axis |
| Applicatio vel series compatibiles | SINAMICS S120 drive systems using CU310-2 architecture |
Identificatio exacta.
Match 6SL3040-1LA01-0AA0 character by character and confirm the complete SINAMICS S120 CU310-2 PN Control Unit designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
CU310-2 PN est unitas controlis SINAMICS S120 ad applicationes impulsum unius axis habens interfaciem PROFINET integratam, et sine carta CompactFlash suppeditatur.
The control unit exchanges cyclic control data, diagnostics and engineering traffic over PROFINET. The unit provides the control hardware for supported SINAMICS S120 power modules and application functions. The required CompactFlash card and its drive project must be selected and prepared separately.
Key Functions
PROFINET Drive Integration
The control unit exchanges cyclic control data, diagnostics and engineering traffic over PROFINET.
Single-Axis Control Platform
The unit provides the control hardware for supported SINAMICS S120 power modules and application functions.
Removable Project Storage
Carta CompactFlash necesse est et proiectum eius disci separatim seligendum parandumque.
Official Specifications
| Alimentatio electrica electronica | 24 V DC (20.4 ad 28.8 V) |
|---|---|
| Maxima Consumptio Electrica | 0,8 A |
| Maxima Pēnsum Perditiōnis | 20 W |
| Maxima Fusibilis Tutela | 20 A |
| Ingressus Digitales | 11 canales |
| Intervalum Tensionis Intrarum Digitalium | -3 usque ad 30 V |
| Nivea Signali Input Digitalis | Inferius: -3 ad 5 V; superius: 15 ad 30 V |
| Tempus Responsionis Input Digitalis | 50 µs ab inferiore ad superius; 150 µs a superiore ad inferius |
| Input/Output Digitalis Bidirectionale | 8 canales non-isolati, qui ut input aut output configurari possunt |
| Tempus responsionis ingressus digitalis I/O | 5 µs ab imo ad summo; 50 µs a summo ad imo |
| Praeceptum electricum egressus digitalis | 24 V DC, maxime 500 mA per egressum, protectio continua contra curtum circuitum |
| Intratio analogica | 1 canalibus commutabilis inter ingressum tensionis et ingressum currentis |
| Ingressus analogus tensionis | -10 usque ad 10 V; resolutio 12-bit cum signo |
| Analogica intratio currentis | -20 usque ad 20 mA; resolutio 11-bit cum signo |
| Connesiones Communicationis | 1 DRIVE-CLiQ, 2 PROFINET, et 1 Ethernet |
| Connesiones mensurationis et sensorum | 3 foramina mensurae et 1 conexio sensoris temperaturae |
| Fissura Cartae Flash | 1 |
| Conexio Terrae Protectoris | 1 vitis M5 |
| Sectio Transversa Conductoris Alimentationis | Maximum 2,5 mm² (AWG 14) |
| Sectio Transversa Conductoris Signali Digitalis | Maximum 1,5 mm² (AWG 16) |
Quaestiones Frequenter Rogatae
Num 6SL3040-1LA01-0AA0 cum carta CompactFlash mittitur?
Non; installe le cartam approbatam continens firmawarum ductus validatam et projectum.
Quae rete fabricae connectit ad 6SL3040-1LA01-0AA0?
Utere interfaciem PROFINET integratam cum nomine dispositivi configurato et parametris IP.
Quid copiare debes antequam 6SL3040-1LA01-0AA0 substituis?
Reserva integram projectum STARTER vel Startdrive, parametres, regulas securitatis, licentias et contenta cartae.
Num 6SL3040-1LA01-0AA0 cum quocumque modulo potentiae SINAMICS coniungi potest?
Non; verifica typum moduli potentiae, combinationem firmawaris et topologiam DRIVE-CLiQ quae sunt approbatae.
Quomodo tractare debes cartam memoriae pro 6SL3040-1LA01-0AA0?
Remove et insere cartam CompactFlash approbatam solum sub conditionibus documentatis de potentia et descensu electrostatico.
Quae data securitatis retinenda sunt pro 6SL3040-1LA01-0AA0?
Preserve the safety parameter set, checksums, passwords and acceptance documentation used by the installed drive.
Which checks complete commissioning of 6SL3040-1LA01-0AA0?
Verify PROFINET communication, encoder feedback, DRIVE-CLiQ nodes, parameters, safety functions and the authorized motion test.
Compatibility & Ordering Notes
Index Compatibilitatis
- Use only a supported SINAMICS S120 power module and firmware combination.
- Preserve the validated CompactFlash contents and drive parameter set.
- Repeat the required safety acceptance after hardware replacement.